Forehead monitoring of heart rate in neonatal intensive care

被引:1
|
作者
Stockwell, S. J. [1 ]
Kwok, T. C. [2 ]
Morgan, S. P. [1 ]
Sharkey, D. [2 ]
Hayes-Gill, B. R. [1 ]
机构
[1] Univ Nottingham, Fac Engn, Opt & Photon Res Grp, Nottingham, England
[2] Univ Nottingham, Ctr Perinatal Res Lifespan & Populat Hlth, Sch Med, Nottingham, England
基金
英国工程与自然科学研究理事会; 英国医学研究理事会;
关键词
photoplethysmogram; PPG; neonatal; heart rate; forehead; reflectance-mode; pulse oximeter Min; 5-Max; 8; NICU (neonatal intensive care unit);
D O I
10.3389/fphys.2023.1127419
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Heart rate is an extremely important physiological parameter to measure in critically unwell infants, as it is the main physiological marker that changes in response to a change in infant condition. Heart rate is routinely measured peripherally on a limb with a pulse oximeter. However, when infants are critically unwell, the blood supply to these peripheries is reduced in preference for central perfusion of vital organs such as the brain and heart. Measurement of heart rate with a reflection mode photoplethysmogram (PPG) sensor on the forehead could help minimise this problem and make it easier for other important medical equipment, such as cannulas, to be placed on the limbs. This study compares heart rates measured with a forehead-based PPG sensor against a wrist-based PPG sensor in 19 critically unwell infants in neonatal intensive care collecting 198 h of data. The two heart rates were compared using positive percentage agreement, Spearman's correlation coefficient and Bland-Altman analysis. The forehead PPG sensor showed good agreement with the wrist-based PPG sensor with limits of agreement of 8.44 bpm, bias of -0.22 bpm; positive percentage agreement of 98.87%; and Spearman's correlation coefficient of 0.9816. The analysis demonstrates that the forehead is a reliable alternative location for measuring vital signs using the PPG.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Advanced Hemodynamic Monitoring in the Neonatal Intensive Care Unit
    de Boode, Willem-Pieter
    CLINICS IN PERINATOLOGY, 2020, 47 (03) : 423 - +
  • [22] CEREBRAL FUNCTION MONITORING IN NEONATAL INTENSIVE-CARE
    DODD, KL
    ARCHIVES OF DISEASE IN CHILDHOOD, 1978, 53 (08) : 687 - 687
  • [23] Continuous EEG Monitoring in the Neonatal Intensive Care Unit
    McCoy, Blathnaid
    Hahn, Cecil D.
    JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 2013, 30 (02) : 106 - 114
  • [24] Air quality monitoring in a neonatal intensive care unit
    Toyooka, K
    Miyazawa, H
    Naiki, Y
    Ishii, Y
    Nishiyama, F
    Kuratsuji, T
    Kirikae, T
    JAPANESE JOURNAL OF INFECTIOUS DISEASES, 2001, 54 (02) : 87 - 88
  • [25] Forehead reflectance photoplethysmography to monitor heart rate: preliminary results from neonatal patients
    Grubb, M. R.
    Carpenter, J.
    Crowe, J. A.
    Teoh, J.
    Marlow, N.
    Ward, C.
    Mann, C.
    Sharkey, D.
    Hayes-Gill, B. R.
    PHYSIOLOGICAL MEASUREMENT, 2014, 35 (05) : 881 - 893
  • [26] NEONATAL INTENSIVE-CARE UNIT - BASIC EQUIPMENT NEEDS FOR NEONATAL MONITORING
    POMERANCE, JJ
    DUNCAN, RG
    CLINICS IN PERINATOLOGY, 1983, 10 (01) : 189 - 194
  • [27] Effect of camera monitoring and feedback along with training on hospital infection rate in a neonatal intensive care unit
    Meltem Karabay
    Gulsum Kaya
    Taner Hafizoglu
    Oguz Karabay
    Annals of Clinical Microbiology and Antimicrobials, 18
  • [28] Effect of camera monitoring and feedback along with training on hospital infection rate in a neonatal intensive care unit
    Karabay, Meltem
    Kaya, Gulsum
    Hafizoglu, Taner
    Karabay, Oguz
    ANNALS OF CLINICAL MICROBIOLOGY AND ANTIMICROBIALS, 2019, 18 (01)
  • [29] HEART RATE CHARACTERISTICS MONITORING AND CENTRAL NEONATAL APNEA
    Lake, D. E.
    Fairchild, K. D.
    Delos, J. B.
    Lee, H.
    Rusin, C. G.
    Guin, L. E.
    Clark, M. T.
    Kattwinkel, J.
    Moorman, J. R.
    PEDIATRIC RESEARCH, 2011, 70 : 689 - 689
  • [30] Monitoring of heart rate characteristics to detect neonatal sepsis
    Rio, Laura
    Ramelet, Anne-Sylvie
    Ballabeni, Pierluigi
    Stadelmann, Corinne
    Asner, Sandra
    Giannoni, Eric
    PEDIATRIC RESEARCH, 2022, 92 (04) : 1070 - 1074