Forehead monitoring of heart rate in neonatal intensive care

被引:1
|
作者
Stockwell, S. J. [1 ]
Kwok, T. C. [2 ]
Morgan, S. P. [1 ]
Sharkey, D. [2 ]
Hayes-Gill, B. R. [1 ]
机构
[1] Univ Nottingham, Fac Engn, Opt & Photon Res Grp, Nottingham, England
[2] Univ Nottingham, Ctr Perinatal Res Lifespan & Populat Hlth, Sch Med, Nottingham, England
基金
英国工程与自然科学研究理事会; 英国医学研究理事会;
关键词
photoplethysmogram; PPG; neonatal; heart rate; forehead; reflectance-mode; pulse oximeter Min; 5-Max; 8; NICU (neonatal intensive care unit);
D O I
10.3389/fphys.2023.1127419
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Heart rate is an extremely important physiological parameter to measure in critically unwell infants, as it is the main physiological marker that changes in response to a change in infant condition. Heart rate is routinely measured peripherally on a limb with a pulse oximeter. However, when infants are critically unwell, the blood supply to these peripheries is reduced in preference for central perfusion of vital organs such as the brain and heart. Measurement of heart rate with a reflection mode photoplethysmogram (PPG) sensor on the forehead could help minimise this problem and make it easier for other important medical equipment, such as cannulas, to be placed on the limbs. This study compares heart rates measured with a forehead-based PPG sensor against a wrist-based PPG sensor in 19 critically unwell infants in neonatal intensive care collecting 198 h of data. The two heart rates were compared using positive percentage agreement, Spearman's correlation coefficient and Bland-Altman analysis. The forehead PPG sensor showed good agreement with the wrist-based PPG sensor with limits of agreement of 8.44 bpm, bias of -0.22 bpm; positive percentage agreement of 98.87%; and Spearman's correlation coefficient of 0.9816. The analysis demonstrates that the forehead is a reliable alternative location for measuring vital signs using the PPG.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Heart rate monitoring in neonatal intensive care using Markov models
    Jeremic, Aleksandar
    Tan, Kenneth
    2008 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING, VOLS 1-12, 2008, : 485 - +
  • [2] Comparison of Wired and Wireless Heart Rate Monitoring in the Neonatal Intensive Care Unit
    Radeschi, Daniel J.
    Senechal, Eva
    Tao, Lydia
    Lv, Shasha
    Shalish, Wissam
    Sant'Anna, Guilherme
    Kearney, Robert E.
    2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2023,
  • [3] Neonatal Intensive Care Unit Length of Stay Reduction by Heart Rate Characteristics Monitoring
    Swanson, Jonathan R.
    King, William E.
    Sinkin, Robert A.
    Lake, Douglas E.
    Carlo, Waldemar A.
    Schelonka, Robert L.
    Porcelli, Peter J.
    Navarrete, Christina T.
    Bancalari, Eduardo
    L Aschner, Judy
    Perez, Jose A.
    O'Shea, T. Michael
    Walker, M. Whit
    JOURNAL OF PEDIATRICS, 2018, 198 : 162 - 167
  • [4] NEURODEVELOPMENTAL OUTCOME AND ELECTRONIC FETAL HEART-RATE MONITORING IN A NEONATAL INTENSIVE-CARE POPULATION
    HOLMQVIST, P
    SVENNINGSEN, NW
    INGEMARSSON, I
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 1984, 63 (06) : 527 - 532
  • [5] Non-Contact Heart Rate Monitoring in Neonatal Intensive Care Unit using RGB Camera
    Chen, Qiong
    Jiang, Xinyu
    Liu, Xiangyu
    Lu, Chunmei
    Wang, Laishuan
    Chen, Wei
    42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 5822 - 5825
  • [6] Domain Adaptation for Heart Rate Extraction in the Neonatal Intensive Care Unit
    Malafaya, Diogo
    Domingues, Sara
    Oliveira, Helder P.
    2020 IEEE INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICINE, 2020, : 1082 - 1086
  • [7] Towards Continuous Monitoring of Pulse Rate in Neonatal Intensive Care Unit with a Webcam
    Mestha, Lalit K.
    Kyal, Survi
    Xu, Beilei
    Lewis, Leslie Edward
    Kumar, Vijay
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 3817 - 3820
  • [8] Heart Rate Variability Analysis for Seizure Detection in Neonatal Intensive Care Units
    Olmi, Benedetta
    Manfredi, Claudia
    Frassineti, Lorenzo
    Dani, Carlo
    Lori, Silvia
    Bertini, Giovanna
    Cossu, Cesarina
    Bastianelli, Maria
    Gabbanini, Simonetta
    Lanata, Antonio
    BIOENGINEERING-BASEL, 2022, 9 (04):
  • [9] Non-contact heart rate monitoring utilizing camera photoplethysmography in the neonatal intensive care unit - A pilot study
    Aarts, Lonneke A. M.
    Jeanne, Vincent
    Cleary, John P.
    Lieber, C.
    Nelson, J. Stuart
    Oetomo, Sidarto Bambang
    Verkruysse, Wim
    EARLY HUMAN DEVELOPMENT, 2013, 89 (12) : 943 - 948
  • [10] Accuracy of pulse oximetry in assessing heart rate of infants in the neonatal intensive care unit
    Singh, Jasbir K. S. B.
    Kamlin, C. Omar F.
    Morley, Colin J.
    O'Donnell, Colm P. F.
    Donath, Susan M.
    Davis, Peter G.
    JOURNAL OF PAEDIATRICS AND CHILD HEALTH, 2008, 44 (05) : 273 - 275