Respiratory Rate Estimation During Walking Using a Wearable Patch With Modality Attentive Fusion

被引:1
|
作者
Chan, Michael [1 ]
Gazi, Asim H. [2 ]
Aydemir, Varol B. [2 ]
Soliman, Moamen [2 ]
Ozmen, Goktug C. [2 ]
Richardson, Kristine L. [2 ]
Abdallah, Calvin A. [1 ]
Nikbakht, Mohammad [2 ]
Nichols, Christopher [2 ]
Inan, Omer T. [1 ,3 ]
机构
[1] Georgia Inst Technol, Wallace H Coulter Dept Biomed Engn, Atlanta, GA 30332 USA
[2] Georgia Inst Technol, Sch Elect & Comp Engn, Atlanta, GA 30332 USA
[3] Georgia Inst Technol, Sch Elect & Comp Engn, Atlanta, GA 30332 USA
关键词
Attention mechanism; deep learning; explainable artificial intelligence; motion artifacts; respiratory rate (RR); sensor adaptive fusion; wearable health monitoring; SIGNALS; RECOGNITION; EXERCISE;
D O I
10.1109/JSEN.2023.3324931
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Respiratory rate (RR) is an important vital sign to monitor outside the clinic, particularly during physiological challenges such as exercise; unfortunately, ambulatory measurement devices for RR are typically obtrusive and inaccurate. The objective of this work is to allow for accurate and robust RR monitoring with a convenient and small chest-worn wearable patch during walking and exercise recovery periods. Methods: To estimate RR from the wearable patch, respiratory signals were first extracted from electrocardiogram (ECG), photoplethysmogram (PPG), and seismocardiogram (SCG) signals. The optimal channel in each signal was adaptively selected using the respiratory quality index based on fast Fourier transform (RQIFFT). Next, we proposed modality attentive (MA) fusion-which merged spectral-temporal information from different modalities-to address motion artifacts during walking. The fused output was subsequently denoised using a U-Net-based deep learning model and used for final estimation. A dataset of N = 17 subjects was collected to validate the RR estimated during three types of activities: stationary activities, walking (including 6-minute walk test), and running. Major results: Combining and denoising ECG and PPG data using MA fusion and the U-Net achieved the lowest mean absolute error (MAE) (2.21 breaths per minute [brpm]) during walking. After rejecting a small portion of the data (coverage = 84.43%) using RQIFFT, this error was further reduced to 1.59 brpm, which was comparable to the state-of-the-art methods. Conclusion: Applying adaptive channel selection, MA fusion, and U-Net denoising achieved accurate RR estimation from a small chest-worn wearable patch. Significance: This work can enable cardiopulmonary monitoring applications in less controlled settings.
引用
收藏
页码:29831 / 29843
页数:13
相关论文
共 50 条
  • [41] Estimation of respiratory waveform and heart rate using an accelerometer
    Phan, D. H.
    Bonnet, S.
    Guillemaud, R.
    Castelli, E.
    Thi, N. Y. Pham
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 4916 - 4919
  • [42] In-Vehicle Respiratory Rate Estimation Using Accelerometers
    Wang, Ju
    Warnecke, Joana M.
    Deserno, Thomas M.
    PHEALTH 2019, 2019, 261 : 97 - 102
  • [43] Probabilistic Estimation of Respiratory Rate using Gaussian Processes
    Pimentel, Marco A. F.
    Clifton, David A.
    Clifton, Lei
    Tarassenko, Lionel
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 2902 - 2905
  • [44] Estimation of CoM and CoP Trajectories During Human Walking Based on a Wearable Visual Odometry Device
    Luo, Jianwen
    Zhao, Ye
    Ruan, Lecheng
    Mao, Shixin
    Fu, Chenglong
    IEEE TRANSACTIONS ON AUTOMATION SCIENCE AND ENGINEERING, 2022, 19 (01) : 396 - 409
  • [45] Estimation of foot trajectory during human walking by a wearable inertial measurement unit mounted to the foot
    Kitagawa, Naoki
    Ogihara, Naomichi
    GAIT & POSTURE, 2016, 45 : 110 - 114
  • [46] Position Tracking During Human Walking Using an Integrated Wearable Sensing System
    Zizzo, Giulio
    Ren, Lei
    SENSORS, 2017, 17 (12)
  • [47] Zephyr: Ubiquitous Accurate multi-Sensor Fusion-based Respiratory Rate Estimation Using Smartphones
    Aly, Heba
    Youssef, Moustafa
    IEEE INFOCOM 2016 - THE 35TH ANNUAL IEEE INTERNATIONAL CONFERENCE ON COMPUTER COMMUNICATIONS, 2016,
  • [48] Smartwatch based respiratory rate estimation during sleep using CNN/LSTM neural network
    Havriushenko, Anastasiia
    Slyusarenko, Kostyantyn
    Fedorin, Illia
    2020 IEEE 40TH INTERNATIONAL CONFERENCE ON ELECTRONICS AND NANOTECHNOLOGY (ELNANO), 2020, : 584 - 587
  • [49] Toward Early Severity Assessment of Obstructive Lung Disease Using Multi-Modal Wearable Sensor Data Fusion During Walking
    Rahman, Md Juber
    Nemati, Ebrahim
    Rahman, Mahbubur
    Vatanparvar, Korosh
    Nathan, Viswam
    Kuang, Jilong
    42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 5935 - 5938
  • [50] Step-Size Estimation Using Fusion of Multiple Wearable Inertial Sensors
    Tjhai, Chandra
    O'Keefe, Kyle
    2017 INTERNATIONAL CONFERENCE ON INDOOR POSITIONING AND INDOOR NAVIGATION (IPIN), 2017,