Respiratory Rate Estimation During Walking Using a Wearable Patch With Modality Attentive Fusion

被引:1
|
作者
Chan, Michael [1 ]
Gazi, Asim H. [2 ]
Aydemir, Varol B. [2 ]
Soliman, Moamen [2 ]
Ozmen, Goktug C. [2 ]
Richardson, Kristine L. [2 ]
Abdallah, Calvin A. [1 ]
Nikbakht, Mohammad [2 ]
Nichols, Christopher [2 ]
Inan, Omer T. [1 ,3 ]
机构
[1] Georgia Inst Technol, Wallace H Coulter Dept Biomed Engn, Atlanta, GA 30332 USA
[2] Georgia Inst Technol, Sch Elect & Comp Engn, Atlanta, GA 30332 USA
[3] Georgia Inst Technol, Sch Elect & Comp Engn, Atlanta, GA 30332 USA
关键词
Attention mechanism; deep learning; explainable artificial intelligence; motion artifacts; respiratory rate (RR); sensor adaptive fusion; wearable health monitoring; SIGNALS; RECOGNITION; EXERCISE;
D O I
10.1109/JSEN.2023.3324931
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Respiratory rate (RR) is an important vital sign to monitor outside the clinic, particularly during physiological challenges such as exercise; unfortunately, ambulatory measurement devices for RR are typically obtrusive and inaccurate. The objective of this work is to allow for accurate and robust RR monitoring with a convenient and small chest-worn wearable patch during walking and exercise recovery periods. Methods: To estimate RR from the wearable patch, respiratory signals were first extracted from electrocardiogram (ECG), photoplethysmogram (PPG), and seismocardiogram (SCG) signals. The optimal channel in each signal was adaptively selected using the respiratory quality index based on fast Fourier transform (RQIFFT). Next, we proposed modality attentive (MA) fusion-which merged spectral-temporal information from different modalities-to address motion artifacts during walking. The fused output was subsequently denoised using a U-Net-based deep learning model and used for final estimation. A dataset of N = 17 subjects was collected to validate the RR estimated during three types of activities: stationary activities, walking (including 6-minute walk test), and running. Major results: Combining and denoising ECG and PPG data using MA fusion and the U-Net achieved the lowest mean absolute error (MAE) (2.21 breaths per minute [brpm]) during walking. After rejecting a small portion of the data (coverage = 84.43%) using RQIFFT, this error was further reduced to 1.59 brpm, which was comparable to the state-of-the-art methods. Conclusion: Applying adaptive channel selection, MA fusion, and U-Net denoising achieved accurate RR estimation from a small chest-worn wearable patch. Significance: This work can enable cardiopulmonary monitoring applications in less controlled settings.
引用
收藏
页码:29831 / 29843
页数:13
相关论文
共 50 条
  • [31] Respiratory Rate Estimation During Walking/Running Activities Using Principal Components Estimated from Signals Recorded by a Smart Garment Embedding Piezoresistive Sensors
    Raiano, Luigi
    Di Tocco, Joshua
    Massaroni, Carlo
    Di Pino, Giovanni
    Schena, Emiliano
    Formica, Domenico
    2021 IEEE INTERNATIONAL WORKSHOP ON METROLOGY FOR INDUSTRY 4.0 & IOT (IEEE METROIND4.0 & IOT), 2021, : 544 - 549
  • [32] An IMU-Based Wearable System for Respiratory Rate Estimation in Static and Dynamic Conditions
    Angelucci, Alessandra
    Aliverti, Andrea
    CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2023, 14 (03) : 351 - 363
  • [33] Measuring Uncertainty During Respiratory Rate Estimation Using Pressure-Sensitive Mats
    Nizami, Shermeen
    Bekele, Amente
    Hozayen, Mohamed
    Greenwood, Kimberley J.
    Harrold, JoAnn
    Green, James R.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2018, 67 (07) : 1535 - 1542
  • [34] An IMU-Based Wearable System for Respiratory Rate Estimation in Static and Dynamic Conditions
    Alessandra Angelucci
    Andrea Aliverti
    Cardiovascular Engineering and Technology, 2023, 14 : 351 - 363
  • [35] A Novel Respiratory Rate Estimation Method for Sound-Based Wearable Monitoring Systems
    Zhang, Jianmin
    Ser, Wee
    Goh, Daniel Yam Thiam
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 3213 - 3216
  • [36] Pilot Study on Electrocardiogram Derived Respiratory Rate Using a Wearable Armband
    Lazaro, Jesus
    Bailon, Raquel
    Gil, Eduardo
    Noh, Yeonsik
    Laguna, Pablo
    Chon, Ki H.
    2018 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), 2018, 45
  • [37] Novel Continuous Respiratory Rate Monitoring Using an Armband Wearable Sensor
    Huang, Nicholas
    Zhou, Menglian
    Bian, Dayi
    Mehta, Pooja
    Shah, Milan
    Rajput, Kuldeep Singh
    Selvaraj, Nandakumar
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 7470 - 7475
  • [38] Estimation of Respiratory Rate from Thermography Using Respiratory Likelihood Index
    Takahashi, Yudai
    Gu, Yi
    Nakada, Takaaki
    Abe, Ryuzo
    Nakaguchi, Toshiya
    SENSORS, 2021, 21 (13)
  • [39] Respiratory Rate Estimation Using Respiratory Sinus Arrhythmia from Photoplethysmography
    Karlen, Walter
    Brouse, Christopher J.
    Cooke, Erin
    Ansermino, J. Mark
    Dumont, Guy A.
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 1201 - 1204
  • [40] Posture estimation and human support using wearable sensors and walking-aid robot
    Huang, Jian
    Xu, Wenxia
    Mohammed, Samer
    Shu, Zhen
    ROBOTICS AND AUTONOMOUS SYSTEMS, 2015, 73 : 24 - 43