Respiratory Rate Estimation During Walking Using a Wearable Patch With Modality Attentive Fusion

被引:1
|
作者
Chan, Michael [1 ]
Gazi, Asim H. [2 ]
Aydemir, Varol B. [2 ]
Soliman, Moamen [2 ]
Ozmen, Goktug C. [2 ]
Richardson, Kristine L. [2 ]
Abdallah, Calvin A. [1 ]
Nikbakht, Mohammad [2 ]
Nichols, Christopher [2 ]
Inan, Omer T. [1 ,3 ]
机构
[1] Georgia Inst Technol, Wallace H Coulter Dept Biomed Engn, Atlanta, GA 30332 USA
[2] Georgia Inst Technol, Sch Elect & Comp Engn, Atlanta, GA 30332 USA
[3] Georgia Inst Technol, Sch Elect & Comp Engn, Atlanta, GA 30332 USA
关键词
Attention mechanism; deep learning; explainable artificial intelligence; motion artifacts; respiratory rate (RR); sensor adaptive fusion; wearable health monitoring; SIGNALS; RECOGNITION; EXERCISE;
D O I
10.1109/JSEN.2023.3324931
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Respiratory rate (RR) is an important vital sign to monitor outside the clinic, particularly during physiological challenges such as exercise; unfortunately, ambulatory measurement devices for RR are typically obtrusive and inaccurate. The objective of this work is to allow for accurate and robust RR monitoring with a convenient and small chest-worn wearable patch during walking and exercise recovery periods. Methods: To estimate RR from the wearable patch, respiratory signals were first extracted from electrocardiogram (ECG), photoplethysmogram (PPG), and seismocardiogram (SCG) signals. The optimal channel in each signal was adaptively selected using the respiratory quality index based on fast Fourier transform (RQIFFT). Next, we proposed modality attentive (MA) fusion-which merged spectral-temporal information from different modalities-to address motion artifacts during walking. The fused output was subsequently denoised using a U-Net-based deep learning model and used for final estimation. A dataset of N = 17 subjects was collected to validate the RR estimated during three types of activities: stationary activities, walking (including 6-minute walk test), and running. Major results: Combining and denoising ECG and PPG data using MA fusion and the U-Net achieved the lowest mean absolute error (MAE) (2.21 breaths per minute [brpm]) during walking. After rejecting a small portion of the data (coverage = 84.43%) using RQIFFT, this error was further reduced to 1.59 brpm, which was comparable to the state-of-the-art methods. Conclusion: Applying adaptive channel selection, MA fusion, and U-Net denoising achieved accurate RR estimation from a small chest-worn wearable patch. Significance: This work can enable cardiopulmonary monitoring applications in less controlled settings.
引用
收藏
页码:29831 / 29843
页数:13
相关论文
共 50 条
  • [1] Respiratory Rate Estimation during Walking and Running Using Breathing Sounds Recorded with a Microphone
    Romano, Chiara
    Nicolo, Andrea
    Innocenti, Lorenzo
    Bravi, Marco
    Miccinilli, Sandra
    Sterzi, Silvia
    Sacchetti, Massimo
    Schena, Emiliano
    Massaroni, Carlo
    BIOSENSORS-BASEL, 2023, 13 (06):
  • [2] Estimation of ventilatory thresholds during exercise using respiratory wearable sensors
    Contreras-Briceno, Felipe
    Cancino, Jorge
    Espinosa-Ramirez, Maximiliano
    Fernandez, Gonzalo
    Johnson, Vader
    Hurtado, Daniel E.
    NPJ DIGITAL MEDICINE, 2024, 7 (01):
  • [3] Respiratory Rate Monitoring Using Acoustic Resonance and Kinematic Data From a Chest Wearable Patch
    Artunduaga, M.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2024, 209
  • [4] ECG Derived Respiratory Rate Estimation for Wearable Devices
    Rajagopalan, Pradeep
    Ramachandran, Sabarish
    2017 INTERNATIONAL CONFERENCE ON COMPUTATIONAL INTELLIGENCE IN DATA SCIENCE (ICCIDS), 2017,
  • [5] Clinical Validation of Respiratory Rate Estimation Using Acoustic Signals from a Wearable Device
    Abdulsadig, Rawan S.
    Devani, Nikesh
    Singh, Sukhpreet
    Patel, Zaibaa
    Pramono, Renard Xaviero Adhi
    Mandal, Swapna
    Rodriguez-Villegas, Esther
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (23)
  • [6] An Accelerometer-Based Wearable Patch for Robust Respiratory Rate and Wheeze Detection Using Deep Learning
    Sang, Brian
    Wen, Haoran
    Junek, Gregory
    Neveu, Wendy
    Di Francesco, Lorenzo
    Ayazi, Farrokh
    Biosensors, 2024, 14 (03):
  • [7] An Accelerometer-Based Wearable Patch for Robust Respiratory Rate and Wheeze Detection Using Deep Learning
    Sang, Brian
    Wen, Haoran
    Junek, Gregory
    Neveu, Wendy
    Di Francesco, Lorenzo
    Ayazi, Farrokh
    BIOSENSORS-BASEL, 2024, 14 (03):
  • [8] Continuous respiratory rate estimation with a wearable temperature sensor during cycling exercise: a feasibility study
    Massaroni, Carlo
    Romano, Chiara
    Nicolo, Andrea
    Innocenti, Lorenzo
    Sacchetti, Massimo
    Schena, Emiliano
    2022 IEEE INTERNATIONAL WORKSHOP ON SPORT TECHNOLOGY AND RESEARCH (IEEE STAR 2022), 2022, : 117 - 121
  • [9] Position estimation by wearable walking navigation system for visually impaired with sensor fusion
    Watanabe H.
    Yamamoto Y.
    Tanzawa T.
    Kotani S.
    IEEJ Transactions on Industry Applications, 2011, 131 (04) : 490 - 496+10
  • [10] Estimation of Individual Muscular Forces of the Lower Limb during Walking Using a Wearable Sensor System
    Kim, Suin
    Ro, Kyongkwan
    Bae, Joonbum
    JOURNAL OF SENSORS, 2017, 2017