Performance of a heat recovery ventilation system for controlling human exposure to airborne particles in a residential building

被引:4
|
作者
Park, Seongjun [1 ]
Lee, Shinhye [2 ]
Yeo, Myoung-Souk [2 ,3 ]
Rim, Donghyun [1 ]
机构
[1] Penn State Univ, Dept Architectural Engn, University Pk, PA 16802 USA
[2] Seoul Natl Univ, Dept Architecture & Architectural Engn, Seoul, South Korea
[3] Seoul Natl Univ, Inst Construct & Environm Engn, Seoul, South Korea
基金
新加坡国家研究基金会; 美国国家科学基金会;
关键词
Indoor air quality; PM2; 5; Exposure control; Indoor emissions; Mass balance model; Bypass factor; PORTABLE AIR CLEANERS; ULTRAFINE PARTICLES; FINE PARTICLES; CONTROL STRATEGIES; SOURCE EMISSION; OUTDOOR; IMPACT; RATES; INFILTRATION; FILTRATION;
D O I
10.1016/j.buildenv.2023.110412
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Heat recovery ventilation (HRV) system is emerging as a sustainable technology to reduce human exposure to air pollutants in residential buildings. However, there is a lack of information on the HRV system performance for controlling both indoor-generated and outdoor-generated particles in a residential building. To fill this knowl-edge gap, we conducted field monitoring of indoor airborne particles with two representative HRV system operating modes (ventilation and circulation modes) in a full-scale residential testbed. The results reveal that the filter efficiency, airflow rate, and filter bypass factor of the HRV system play important roles in indoor particle concentrations. The indoor/outdoor concentration ratio is reduced by 72%-92% when operating the HRV sys-tem. For both circulation and ventilation modes, the bypass factor is crucial for the particle removal performance of the HRV system. A 20% filter bypass factor leads to up to a 50% increase in indoor exposure to outdoor-originated and indoor-generated PM2.5 compared to the no-bypass scenario. Although circulation mode per-formed better than ventilation mode, both operating modes with a minimal bypass factor can effectively remove particles generated from indoor emission sources (e.g., incense stick burning and bacon pan frying). The study results suggest that HRV system can reduce human exposure to indoor-generated particles by 56%-90% and particle control performance hinges upon minimizing HRV filter bypass.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] An integrated heat recovery and storage system for a residential building
    Bolt, Andre A.
    Dincer, Ibrahim
    Agelin-Chaab, Martin
    ENERGY STORAGE, 2019, 1 (05)
  • [2] RESIDENTIAL VENTILATION WITH HEAT RECOVERY.
    Shoukri, M.
    D'Silva, N.S.
    Research Review - Ontario Hydro, 1981, (04): : 9 - 13
  • [3] Continuous automated ventilation heat recovery efficiency performance assessment using building monitoring system
    Kull, Tuule Mall
    Mikola, Alo
    Tukia, Andres
    Kose, Ahmet
    Petlenkov, Eduard
    Thalfeldt, Martin
    COLD CLIMATE HVAC & ENERGY 2021, 2021, 246
  • [4] Optimization of an earth-air heat exchanger combined with a heat recovery ventilation for residential building needs
    Lapertot, Arnaud
    Cuny, Mathias
    Kadoch, Benjamin
    Le Metayer, Olivier
    ENERGY AND BUILDINGS, 2021, 235
  • [5] Evaluation of Energy and Ventilation Performance of Individual Room Control Ventilation System in Residential Building
    Shim, Chanhyung
    Seong, Namchul
    Hong, Goopyo
    ASHRAE TRANSACTIONS 2023, VOL 129, PT 1, 2023, 129 : 661 - 666
  • [6] Experimental and numerical analysis on hybrid ventilation system performance for residential building
    Yoshino, H
    Liu, J
    Lee, J
    Wada, J
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 157 - 164
  • [7] Performance of a novel mechanical ventilation heat recovery heat pump system
    Riffat, SB
    Gillott, MC
    APPLIED THERMAL ENGINEERING, 2002, 22 (07) : 839 - 845
  • [8] Integrated effects of the heat recovery ventilation and heat source on decay rate of indoor airborne particles: A comparative study
    Jahanbin, Aminhossein
    Semprini, Giovanni
    JOURNAL OF BUILDING ENGINEERING, 2022, 50
  • [9] School building energy performance and classroom air environment implemented with the heat recovery heat pump and displacement ventilation system
    Wang, Yang
    Zhao, Fu-Yun
    Kuckelkorn, Jens
    Spliethoff, Hartmut
    Rank, Ernst
    APPLIED ENERGY, 2014, 114 : 58 - 68
  • [10] A review of heat recovery technologies and their frost control for residential building ventilation in cold climate regions
    Bai, H. Y.
    Liu, P.
    Alonso, M. Justo
    Mathisen, H. M.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2022, 162