Clinical application of spinal robot in cervical spine surgery: safety and accuracy of posterior pedicle screw placement in comparison with conventional freehand methods

被引:16
|
作者
Zhou, Lu-Ping [1 ,2 ]
Zhang, Ren-Jie [1 ,2 ]
Zhang, Wen-Kui [1 ,2 ]
Kang, Liang [1 ,2 ]
Li, Kai-Xuan [1 ,2 ]
Zhang, Hua-Qing [1 ,2 ]
Jia, Chong-Yu [1 ,2 ]
Zhang, Yin-Shun [1 ,2 ]
Shen, Cai-Liang [1 ,2 ]
机构
[1] Anhui Med Univ, Affiliated Hosp 1, Dept Orthoped & Spine Surg, Hefei 230022, Anhui, Peoples R China
[2] Anhui Med Univ, Affiliated Hosp 1, Lab Spinal & Spinal Cord Injury Regenerat & Repair, Hefei 230022, Anhui, Peoples R China
关键词
Robot-assisted screw placement; Freehand; Pedicle screw accuracy; Posterior cervical; Cervical traumatic diseases; Risk factor; VERTEBRAL ARTERY INJURY; FACET JOINT VIOLATION; INTERNAL-FIXATION; ATLANTOAXIAL INSTABILITY; RISK; INSTRUMENTATION; NAVIGATION; ANOMALIES;
D O I
10.1007/s10143-023-02027-y
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The novel robot-assisted (RA) technique has been utilized increasingly to improve the accuracy of cervical pedicle screw placement. Although the clinical application of the RA technique has been investigated in several case series and comparative studies, the superiority and safety of RA over conventional freehand (FH) methods remain controversial. Meanwhile, the intra-pedicular accuracy of the two methods has not been compared for patients with cervical traumatic conditions. This study aimed to compare the rate and risk factors of intra-pedicular accuracy of RA versus the conventional FH approach for posterior pedicle screw placement in cervical traumatic diseases. A total of 52 patients with cervical traumatic diseases who received cervical screw placement using RA (26 patients) and FH (26 patients) techniques were retrospectively included. The primary outcome was the intra-pedicular accuracy of cervical pedicle screw placement according to the Gertzbin-Robbins scale. Secondary outcome parameters included surgical time, intraoperative blood loss, postoperative drainage, postoperative hospital stay, and complications. Moreover, the risk factors that possibly affected intra-pedicular accuracy were assessed using univariate analyses. Out of 52 screws inserted using the RA method, 43 screws (82.7%) were classified as grade A, with the remaining 7 (13.5%) and 2 (3.8%) screws classified as grades B and C. In the FH cohort, 60.8% of the 79 screws were graded A, with the remaining screws graded B (21, 26.6%), C (8, 10.1%), and D (2, 2.5%). The RA technique showed a significantly higher rate of optimal intra-pedicular accuracy than the FH method (P = 0.008), but there was no significant difference between the two groups in terms of clinically acceptable accuracy (P = 0.161). Besides, the RA technique showed remarkably longer surgery time, less postoperative drainage, shorter postoperative hospital stay, and equivalent intraoperative blood loss and complications than the FH technique. Furthermore, the univariate analyses showed that severe obliquity of the lateral atlantoaxial joint in the coronal plane (P = 0.003) and shorter width of the lateral mass at the inferior margin of the posterior arch (P = 0.014) were risk factors related to the inaccuracy of C1 screw placement. The diagnosis of HRVA (P < 0.001), severe obliquity of the lateral atlantoaxial joint in the coronal plane (P < 0.001), short pedicle width (P < 0.001), and short pedicle height (P < 0.001) were risk factors related to the inaccuracy of C2 screw placement. RA cervical pedicle screw placement was associated with a higher rate of optimal intra-pedicular accuracy to the FH technique for patients with cervical traumatic conditions. The severe obliquity of the lateral atlantoaxial joint in the coronal plane independently contributed to high rates of the inaccuracy of C1 and C2 screw placements. RA pedicle screw placement is safe and useful for cervical traumatic surgery.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Comparison of short-term clinical outcomes between robot-assisted and freehand pedicle screw placement in spine surgery: a meta-analysis and systematic review
    Li, Yiyang
    Wang, Yan
    Ma, Xinlong
    Ma, Jianxiong
    Dong, Benchao
    Yang, Peichuan
    Sun, Yadi
    Zhou, Liyun
    Shen, Jiahui
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [22] Accuracy analysis of pedicle screw placement in posterior scoliosis surgery - Comparison between conventional fluoroscopic and computer-assisted technique
    Kotani, Yoshihisa
    Abumi, Kuniyoshi
    Ito, Manabu
    Takahata, Masahiko
    Sudo, Hideki
    Ohshima, Shigeki
    Minami, Akio
    SPINE, 2007, 32 (14) : 1543 - 1550
  • [23] Clinical Pedicle Screw Accuracy and Deviation From Planning in Robot-Guided Spine Surgery
    van Dijk, Joris D.
    van den Ende, Roy P. J.
    Stramigioli, Stefano
    Koechling, Matthias
    Hoess, Norbert
    SPINE, 2015, 40 (17) : E986 - E991
  • [24] Accuracy of robot-guided versus freehand fluoroscopy-assisted pedicle screw insertion in thoracolumbar spinal surgery
    Molliqaj, Granit
    Schatlo, Bawarjan
    Alaid, Awad
    Solomiichuk, Volodymyr
    Rohde, Veit
    Schaller, Karl
    Tessitore, Enrico
    NEUROSURGICAL FOCUS, 2017, 42 (05)
  • [25] Validation of Freehand Cervical Pedicle Screw Placement in Subaxial Spine Using the "Burcev Technique": A Cadaveric Study
    Jain, Mantu
    Sahu, Rabi N.
    Gaikwad, Manisha R.
    Panda, Sashikanta
    Tirpude, Amit
    Bag, Nerbadyswari D.
    JOURNAL OF NEUROSCIENCES IN RURAL PRACTICE, 2021, 12 (03) : 555 - 559
  • [26] Safety and accuracy of freehand versus navigated C2 pars or pedicle screw placement
    Hlubek, Randall J.
    Bohl, Michael A.
    Cole, Tyler S.
    Morgan, Clinton D.
    Xu, David S.
    Chang, Steve W.
    Turner, Jay D.
    Kakarla, U. Kumar
    SPINE JOURNAL, 2018, 18 (08): : 1374 - 1381
  • [27] The Accuracy and Safety of a Pedicle Screw Using the Freehand Technique in Minimally Invasive Scoliosis Surgery
    Nam, Yunjin
    Chang, Dong-Gune
    Kim, Hong Jin
    Ha Kim, Young
    Lee, Sangmin
    Yang, Jae Hyuk
    Suh, Seung Woo
    NEUROSPINE, 2023, 20 (01) : 240 - 247
  • [28] Safety and risk factors of TINAVI robot-assisted percutaneous pedicle screw placement in spinal surgery
    Zhang, Ren-Jie
    Zhou, Lu-Ping
    Zhang, Lai
    Zhang, Hua-Qing
    Zhang, Jian-Xiang
    Shen, Cai-Liang
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [29] Safety and risk factors of TINAVI robot-assisted percutaneous pedicle screw placement in spinal surgery
    Ren-Jie Zhang
    Lu-Ping Zhou
    Lai Zhang
    Hua-Qing Zhang
    Jian-Xiang Zhang
    Cai-Liang Shen
    Journal of Orthopaedic Surgery and Research, 17
  • [30] Pedicle screw accuracy in clinical utilization of minimally invasive navigated robot-assisted spine surgery
    Arnold B. Vardiman
    David J. Wallace
    Neil R. Crawford
    Jessica R. Riggleman
    Leigh A. Ahrendtsen
    Charles G. Ledonio
    Journal of Robotic Surgery, 2020, 14 : 409 - 413