Pedicle screw accuracy in clinical utilization of minimally invasive navigated robot-assisted spine surgery

被引:0
|
作者
Arnold B. Vardiman
David J. Wallace
Neil R. Crawford
Jessica R. Riggleman
Leigh A. Ahrendtsen
Charles G. Ledonio
机构
[1] University of Texas Health San Antonio,Department of Neurosurgery
[2] A Division of Globus Medical,Musculoskeletal Education and Research Center (MERC)
[3] Inc,undefined
来源
关键词
Robotic-navigated; Pedicle screw placement accuracy; Minimally invasive surgery; Robotic-assisted spine surgery;
D O I
暂无
中图分类号
学科分类号
摘要
In the emerging field of robot-assisted spine surgery, the radiographic evaluation of pedicle screw accuracy in clinical application is an area of high interest. This study describes the pedicle screw accuracy of the first 56 consecutive cases in which navigated robotic assistance was used in a private practice clinical setting. A retrospective, Institutional Review Board-exempt review of the first 56 navigated robot-assisted spine surgery cases was performed. Pedicle screw malposition, reposition, and return to operating room (OR) rates were collected. A CT-based Gertzbein and Robbins system (GRS) was used to classify pedicle screw accuracy. In the first 56 robotic cases, 356 total pedicle screws were placed. Eight screws were placed without the robot due to surgeon discretion. Of the 348 pedicle screws inserted by navigated robotic guidance, only 2.6% (9/348) were repositioned, resulting in a 97.4% (339/348) successful screw placement rate. The average age was 64, and 48% were female. Average body mass index was 31 kg/m2. Based on the GRS CT-based grading, 97.7% (340/348) were graded A or B, 1.7% (6/348) screws were graded C, and only 0.6% (2/348) of screws were graded D. Two complications, explantation of interbody and vacuum-assisted wound closure, were reported as requiring a return to the OR, but these were not related to robotic guidance or pedicle screws. This study demonstrated a high level of accuracy (97.7%) in the first 56 cases using navigated, robot-assisted surgery based on the GRS. There were two non-screw-related complications requiring return to the operating room.
引用
收藏
页码:409 / 413
页数:4
相关论文
共 50 条
  • [1] Pedicle screw accuracy in clinical utilization of minimally invasive navigated robot-assisted spine surgery
    Vardiman, Arnold B.
    Wallace, David J.
    Crawford, Neil R.
    Riggleman, Jessica R.
    Ahrendtsen, Leigh A.
    Ledonio, Charles
    JOURNAL OF ROBOTIC SURGERY, 2020, 14 (03) : 409 - 413
  • [2] Navigated robotic assistance improves pedicle screw accuracy in minimally invasive surgery of the lumbosacral spine: 600 pedicle screws in a single institution
    Wallace, David J.
    Vardiman, Arnold B.
    Booher, Grant A.
    Crawford, Neil R.
    Riggleman, Jessica R.
    Greeley, Samantha L.
    Ledonio, Charles G.
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2020, 16 (01):
  • [3] Does the accuracy of pedicle screw placement differ between the attending surgeon and resident in navigated robotic-assisted minimally invasive spine surgery?
    Vardiman, Arnold B.
    Wallace, David J.
    Booher, Grant A.
    Crawford, Neil R.
    Riggleman, Jessica R.
    Greeley, Samantha L.
    Ledonio, Charles G.
    JOURNAL OF ROBOTIC SURGERY, 2020, 14 (04) : 567 - 572
  • [4] Does the accuracy of pedicle screw placement differ between the attending surgeon and resident in navigated robotic-assisted minimally invasive spine surgery?
    Arnold B. Vardiman
    David J. Wallace
    Grant A. Booher
    Neil R. Crawford
    Jessica R. Riggleman
    Samantha L. Greeley
    Charles G. Ledonio
    Journal of Robotic Surgery, 2020, 14 : 567 - 572
  • [5] Ultrasound-Based Robot-Assisted Drilling for Minimally Invasive Pedicle Screw Placement
    Li, Ruixuan
    Davoodi, Ayoob
    Timmermans, Maikel
    Van Assche, Kaat
    Taylan, Orcun
    Scheys, Lennart
    Tummers, Matthias
    Borghesan, Gianni
    Poorten, Emmanuel Vander
    IEEE TRANSACTIONS ON MEDICAL ROBOTICS AND BIONICS, 2024, 6 (03): : 818 - 828
  • [6] Experiments on robot-assisted navigated drilling and milling of bones for pedicle screw placement
    Ortmaier, T.
    Weiss, H.
    Doebele, S.
    Schreiber, U.
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2006, 2 (04): : 350 - 363
  • [7] Minimally invasive versus conventional fixation of tracer in robot-assisted pedicle screw insertion surgery: a randomized control trial
    Li Yongqi
    Zhang Dehua
    Wu Hongzi
    Zhang Ke
    Yang Rui
    Fang Zhou
    Wang Shaobo
    Liao Yi
    BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)
  • [8] Minimally invasive versus conventional fixation of tracer in robot-assisted pedicle screw insertion surgery: a randomized control trial
    Li Yongqi
    Zhang Dehua
    Wu Hongzi
    Zhang Ke
    Yang Rui
    Fang Zhou
    Wang Shaobo
    Liao Yi
    BMC Musculoskeletal Disorders, 21
  • [9] Factors Affecting the Accuracy of Pedicle Screw Placement in Robot-Assisted Surgery A Multicenter Study
    Toossi, Nader
    Vardiman, Arnold B.
    Benech, Carlo A.
    Kanaly, Charles W.
    Maltenfort, Mitchell G.
    Backes, Danielle M.
    Bucklen, Brandon
    SPINE, 2022, 47 (23) : 1613 - 1619
  • [10] Haptics for Robot-Assisted Minimally Invasive Surgery
    Okamura, A. M.
    Verner, L. N.
    Reiley, C. E.
    Mahvash, M.
    ROBOTICS RESEARCH, 2010, 66 : 361 - 372