Improved accuracy of the biodistribution and internal radiation dosimetry of 13N-ammonia using a total-body PET/CT scanner

被引:5
|
作者
Yu, Xiaofeng [1 ]
Sun, Hongyan [2 ]
Xu, Lian [1 ]
Han, Yuan [1 ]
Wang, Cheng [1 ]
Li, Lianghua [1 ]
Ng, YeeLing [2 ]
Shi, Fuxiao [2 ]
Qiu, Ju [1 ]
Huang, Gang [1 ]
Zhou, Yun [2 ]
Chen, Yumei [1 ,3 ]
Liu, Jianjun [1 ,3 ]
机构
[1] Shanghai Jiao Tong Univ, Renji Hosp, Sch Med, Dept Nucl Med, Shanghai, Peoples R China
[2] United Imaging Healthcare, Cent Res Inst, Shanghai, Peoples R China
[3] Shanghai Jiao Tong Univ, Renji Hosp, Sch Med, Dept Nucl Med, 160 Pujian Rd, Shanghai 200127, Peoples R China
基金
中国国家自然科学基金;
关键词
13N-ammonia; biodistribution; internal radiation dose; total-body PET; CT; uEXPLORER;
D O I
10.1002/mp.16450
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundConventional short-axis PET typically utilizes multi-bed multi-pass acquisition to produce quantitative whole-body dynamic images and cannot record all the uptake information simultaneously, resulting in errors when fitting the time-activity curves (TACs) and calculating radiation doses. PurposeThe aim of this study is to evaluate the N-13-ammonia biodistribution and the internal radiation doses using a 194 cm long total-body PET/CT scanner (uEXPLORER), and make a comparison with the previous short-axis PET results. MethodsTen subjects (age 40-74 years) received N-13-NH3 injection (418.1-670.81 MBq) and were under a dynamic scan for about 60 min with using a 3-dimensional whole-body protocol. ROIs were drawn visually on 11 major organs (brain, thyroid, gallbladder, heart wall, kidneys, liver, pancreas, spleen, lungs, bone marrow, and urinary bladder content) for each subject. TACs were generated using Pmod and the absorbed radiation doses were calculated using Olinda 2.2. To compare with the conventional PET/CT, five points were sampled on uEXPLORER's TACs to mimic the result of a short-axis PET/CT (15 cm axial FOV, consisted of 9 or 10 bed positions). Then the TACs were obtained using the multi-exponential fitting method, and the residence time and radiation dose were also calculated and compared with uEXPLORER. ResultsThe highest absorbed organ doses were the pancreas, thyroid, spleen, heart wall, and kidneys for the male. For the female, the first five highest absorbed organ dose coefficients were the pancreas, heart wall, spleen, lungs, and kidneys. The lowest absorbed dose was found in red marrow both for male and female. The simulated short-axis PET can fit TACs well for the gradually-changed uptake organs but typically underestimated for the rapid-uptake organs during the first-10 min, resulting in errors in the calculated radiation dose. ConclusionuEXPLORER PET/CT can measure N-13-ammonia's TACs simultaneously in all organs of the whole body, which can provide more accurate biodistribution and radiation dose estimation compared with the conventional short-axis scanners.
引用
收藏
页码:5865 / 5874
页数:10
相关论文
共 50 条
  • [41] Coupling of 11C-acetate and 13N-ammonia for measurement of myocardial blood flow in normal rats using the Sherbrooke PET scanner
    Bentourkia, A
    Croteau, E
    Langlois, R
    Aliaga, A
    Rousseau, J
    Cadorette, J
    Bénard, F
    Lesur, O
    Lecomte, R
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1147 - 1150
  • [42] Myocardial blood flow measurements with 13N-ammonia in rats using a Small Animal PET scanner at Rest and Stress:: Impact of anesthesia.
    Croteau, E
    Bénard, F
    Bentourkia, M
    Rousseau, J
    Paquette, M
    Lecomte, R
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 88P - 88P
  • [43] Reproducibility and Accuracy of Quantitative Myocardial Blood Flow Assessment with 82Rb PET: Comparison with 13N-Ammonia PET
    El Fakhri, Georges
    Kardan, Arash
    Sitek, Arkadiusz
    Dorbala, Sharmila
    Abi-Hatem, Nathalie
    Lahoud, Youmna
    Fischman, Alan
    Coughlan, Martha
    Yasuda, Tsunehiro
    Di Carli, Marcelo F.
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (07) : 1062 - 1071
  • [44] Validation of a Monte Carlo model of the uEXPLORER total-body PET scanner using GATE code
    EL Katib, Mahmoud
    Chakir, El Mahjoub
    Sebihi, Rajaa
    Saikouk, Hind
    Nhila, Oussama
    RADIATION PHYSICS AND CHEMISTRY, 2023, 210
  • [45] Accurate modeling and performance evaluation of a total-body pet scanner using Monte Carlo simulations
    Rezaei, Hadi
    Sheikhzadeh, Peyman
    Ghafarian, Pardis
    Zaidi, Habib
    Ay, Mohammad Reza
    MEDICAL PHYSICS, 2023, 50 (11) : 6815 - 6827
  • [46] Utility of Dynamic Perfusion PET Using 13N-Ammonia in Diagnosis of Asymptomatic Recurrence of Fibrosarcoma
    Harisankar, Chidambaram Natrajan Balasubramanian
    Mittal, Bhagwant Rai
    Watts, Ankit
    Bhattacharya, Anish
    Sen, Ramesh
    CLINICAL NUCLEAR MEDICINE, 2011, 36 (02) : 150 - 151
  • [47] Quantification of myocardial blood flow using 13N-ammonia and PET:: Comparison of tracer models
    Choi, Y
    Huang, SC
    Hawkins, RA
    Kim, JY
    Kim, BT
    Hoh, CK
    Chen, K
    Phelps, ME
    Schelbert, HR
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (06) : 1045 - 1055
  • [48] Absolute myocardial blood flow evaluation with 13N-ammonia and 3D PET-CT
    Leccisotti, L.
    Indovina, L.
    Paraggio, L.
    Calcagni, M. L.
    Giordano, A.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2011, 13 (0A) : A80 - A80
  • [49] Quantitative analysis of myocardial perfusion in patients with systemic lupus erythematosus assessed with 13N-ammonia PET/CT
    Alexanderson, Erick
    Martinez Aguilar, Myriam
    Jordan Rios, Antonio
    Magana Bailon, Elisa
    Maury Ordaz, Sergio
    Juarez Orozco, Luis
    Hernandez, Salvador
    Guizar, Carlos
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [50] 13N-ammonia PET/CT can predict progression free survival in patients with suspected recurrent glioma
    Khangembam, B. C.
    Sharma, P.
    Bal, C. S.
    Kumar, R.
    Bandohpadhyaya, G. P.
    Malhotra, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S142 - S142