Robotic pullback technique of a precurved cochlear-implant electrode array using real-time impedance sensing feedback

被引:1
|
作者
Riojas, Katherine E. [1 ]
Bruns, Trevor L. [1 ]
Granna, Josephine [1 ]
Webster, Robert J., III [1 ]
Labadie, Robert F. [2 ]
机构
[1] Vanderbilt Univ, Dept Mech Engn, Nashville, TN 37235 USA
[2] Med Univ South Carolina, Dept Otolaryngol, Charleston, SC 29425 USA
基金
美国国家科学基金会;
关键词
Cochlear implants; Impedance sensing; Robotic surgery; Otology; INSERTION; PROXIMITY;
D O I
10.1007/s11548-022-02772-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose During traditional insertion of cochlear implant (CI) electrode arrays (EAs), surgeons rely on limited tactile feedback and visualization of the EA entering the cochlea to control the insertion. One insertion approach for precurved EAs involves slightly overinserting the EA and then retracting it slightly to achieve closer hugging of the modiolus. In this work, we investigate whether electrical impedance sensing could be a valuable real-time feedback tool to advise this pullback technique. Methods Using a to-scale 3D-printed scala tympani model, a robotic insertion tool, and a custom impedance sensing system, we performed experiments to assess the bipolar insertion impedance profiles for a cochlear CI532/632 precurved EA. Four pairs of contacts from the 22 electrode contacts were chosen based on preliminary testing and monitored in real time to halt the robotic insertion once the closest modiolar position had been achieved but prior to when the angular insertion depth (AID) would be reduced. Results In this setting, the open-loop robotic insertion impedance profiles were very consistent between trials. The exit of each contact from the external stylet of this EA was clearly discernible on the impedance profile. In closed-loop experiments using the pullback technique, the average distance from the electrode contacts to the modiolus was reduced without greatly affecting the AID by using impedance feedback in real time to determine when to stop EA retraction. Conclusion Impedance sensing, and specifically the access resistance component of impedance, could be a valuable real-time feedback tool in the operating room during CI EA insertion. Future work should more thoroughly analyze the effects of more realistic operating room conditions and inter-patient variability on this technique.
引用
收藏
页码:413 / 421
页数:9
相关论文
共 50 条
  • [21] Transparent Thin Film Transistor Electrode Array for Real-Time Electrical Impedance Spectroscopy of Cell Cultures
    Cathcart, Grant A.
    Tixier-Mita, Agnes
    Ihida, Satoshi
    Shark, Faruk A.
    Toshiyoshi, Hiroshi
    2016 IEEE 11TH ANNUAL INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS (NEMS), 2016,
  • [22] Using Real-time Feedback To Improve Surgical Performance on a Robotic Tissue Dissection Task
    Laca, Jasper A.
    Kocielnik, Rafal
    Nguyen, Jessica H.
    You, Jonathan
    Tsang, Ryan
    Wong, Elyssa Y.
    Shtulman, Andrew
    Anandkumar, Anima
    Hung, Andrew J.
    EUROPEAN UROLOGY OPEN SCIENCE, 2022, 46 : 15 - 21
  • [23] Real-Time Electrical Load Emulator Using Optimal Feedback Control Technique
    Rao, Y. Srinivasa
    Chandorkar, Mukul C.
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2010, 57 (04) : 1217 - 1225
  • [24] Real-time monitoring of crystallization from solution by using an interdigitated array electrode sensor
    Tong, Jincheng
    Doumbia, Amadou
    Turner, Michael L.
    Casiraghi, Cinzia
    NANOSCALE HORIZONS, 2021, 6 (06) : 468 - 473
  • [25] Neural Adaptation and Perceptual Learning using a Portable Real-Time Cochlear Implant Simulator in Natural Environments
    Smalt, Christopher J.
    Talavage, Thomas M.
    Pisoni, David B.
    Svirsky, Mario A.
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 1145 - 1148
  • [26] Real-time feedback control of pH within microfluidics using integrated sensing and actuation
    Welch, David
    Christen, Jennifer Blain
    LAB ON A CHIP, 2014, 14 (06) : 1191 - 1197
  • [27] Algorithm for real-time detection of signal patterns using phase synchrony: an application to an electrode array
    Sadeghi, Saman
    MacKay, William A.
    van Dam, R. Michael
    Thompson, Michael
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2011, 22 (02)
  • [28] Real-Time Monitoring of Head and Neck Patient Position Using Pressure Sensing Technique
    Li, J.
    Yu, Y.
    Ahn, P.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [29] Biopsy Needle Integrated with Electrical Impedance Sensing Microelectrode Array towards Real-time Needle Guidance and Tissue Discrimination
    Jaeho Park
    Won-Mook Choi
    Kyuyoung Kim
    Won-Il Jeong
    Joon-Beom Seo
    Inkyu Park
    Scientific Reports, 8
  • [30] Biopsy Needle Integrated with Electrical Impedance Sensing Microelectrode Array towards Real-time Needle Guidance and Tissue Discrimination
    Park, Jaeho
    Choi, Won-Mook
    Kim, Kyuyoung
    Jeong, Won-Il
    Seo, Joon-Beom
    Park, Inkyu
    SCIENTIFIC REPORTS, 2018, 8