Optimal Sizing of a Photovoltaic/Battery Energy Storage System to Supply Electric Substation Auxiliary Systems under Contingency

被引:3
|
作者
Goncalves, Ailton [1 ]
Cavalcanti, Gustavo O. [1 ]
Feitosa, Marcilio A. F. [1 ]
Dias Filho, Roberto F. F. [1 ]
Pereira, Alex C. [2 ]
Jatoba, Eduardo B. [2 ]
de Melo Filho, Jose Bione [2 ]
Marinho, Manoel H. N. [1 ]
Converti, Attilio [3 ]
Gomez-Malagon, Luis A. [1 ]
机构
[1] Univ Pernambuco, Polytech Sch Pernambuco, Dept Syst Engn, Postgrad Program Syst Engn, BR-50720001 Recife, PE, Brazil
[2] Sao Francisco Hydroelect Co Chesf, BR-50761901 Recife, PE, Brazil
[3] Univ Genoa, Dept Civil Chem & Environm Engn, Pole Chem Engn, Via Opera Pia 15, I-16145 Genoa, Italy
关键词
auxiliary systems; battery management systems; microgrids; photovoltaic systems; substation; WIND HYBRID SYSTEM; PV-BATTERY SYSTEMS; MULTIOBJECTIVE OPTIMIZATION; DESIGN; CAPACITY;
D O I
10.3390/en16135165
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Electric substations (ESS) are important facilities that must operate even under contingency to guarantee the electrical system's performance. To achieve this goal, the Brazilian national electricity system operator establishes that alternating current (AC) auxiliary systems of ESS must have, at least, two power supplies, and in the case of failure of these sources, an emergency generator (EG) must at least supply energy to the essential loads. In order to improve the availability of auxiliary systems, a microgrid with other sources, such as photovoltaic (PV) systems and Battery Energy Storage Systems (BESS), can be an alternative. In this case, an economical optimization of the PV/BESS system must be addressed considering the costs associated with the installation and maintenance of equipment, and the gains from the credits generated by the photovoltaic system in the net metering scheme. In this paper, the size of the BESS system was determined to supply energy to the load of auxiliary systems of an ESS, as well as a PV system to achieve a null total cost. Furthermore, multi-objective optimization using the genetic algorithm technique was employed to optimize the size of the hybrid PV/BESS to minimize the investment cost and time when the demand was not met. Simulations under different scenarios of contingency were allowed to obtain the Pareto frontier for the optimal sizing of a PV/BESS system to supply energy to AC auxiliary systems in an ESS under contingency.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] Comparative Analysis of Battery Energy Storage Systems for Mobile Substation and Grid Storage System
    Singh, Prashant
    Anwer, Naqui
    Dattaroy, Arkabrata
    Bhattacharya, Avik
    2022 22ND NATIONAL POWER SYSTEMS CONFERENCE, NPSC, 2022,
  • [42] Multiobjective Optimal Sizing of Hybrid Energy Storage System for Electric Vehicles
    Zhang, Lei
    Hu, Xiaosong
    Wang, Zhenpo
    Sun, Fengchun
    Deng, Junjun
    Dorrell, David. G.
    IEEE TRANSACTIONS ON VEHICULAR TECHNOLOGY, 2018, 67 (02) : 1027 - 1035
  • [43] Optimal Sizing of Battery Energy Storage System (BESS) for Peak Shaving Under Malaysian Electricity Tariff
    Subramani, Gopinath
    Ramachandaramurthy, Vigna K.
    Vijyakumar, Kanendra Naidu
    ADVANCED SCIENCE LETTERS, 2018, 24 (03) : 1861 - 1865
  • [44] A universal optimal sizing for hybrid energy storage system of electric vehicles
    Nguyen-Minh, Tien
    Nguy, Bao-Huy
    Vo-Duy, Thanh
    Ta, Minh C.
    Trovao, Joao Pedro F.
    Antunes, Carlos Henggeler
    JOURNAL OF ENERGY STORAGE, 2024, 92
  • [45] Optimal Sizing and Control of Battery Energy Storage Systems for Hybrid Turboelectric Aircraft
    Sergent, Aaronn
    Ramunno, Michael
    D'Arpino, Matilde
    Canova, Marcello
    Perullo, Christopher
    Sergent, Aaronn (darpino.2@osu.edu), 1600, SAE International (02): : 1266 - 1278
  • [46] Optimal Sizing of Battery/Supercapacitor Hybrid Energy Storage Systems for Frequency Regulation
    Baek, Min-Kyu
    Roh, Jae-Hyung
    Park, Jong-Bae
    Jeong, Woo-Cheol
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2022, 17 (01) : 111 - 120
  • [47] Electric System Cascade Extended Analysis for optimal sizing of an autonomous hybrid CSP/PV/wind system with Battery Energy Storage System and thermal energy storage
    Chennaif, Mohammed
    Zahboune, Hassan
    Elhafyani, Mohammed
    Zouggar, Smail
    ENERGY, 2021, 227
  • [48] Optimal Sizing of Battery/Supercapacitor Hybrid Energy Storage Systems for Frequency Regulation
    Min-Kyu Baek
    Jae-Hyung Roh
    Jong-Bae Park
    Woo-Cheol Jeong
    Journal of Electrical Engineering & Technology, 2022, 17 : 111 - 120
  • [49] Algorithm for optimal sizing of energy storage system paired with photovoltaic generation considering lithium-ion battery degradation
    Shin H.
    Transactions of the Korean Institute of Electrical Engineers, 2019, 68 (06): : 701 - 709
  • [50] Optimal electric bus scheduling method under hybrid energy supply mode of photovoltaic-energy storage system-power grid
    Bie, Yiming
    Qin, Wei
    Wu, Jiabin
    APPLIED ENERGY, 2024, 372