Optimal Sizing of a Photovoltaic/Battery Energy Storage System to Supply Electric Substation Auxiliary Systems under Contingency

被引:3
|
作者
Goncalves, Ailton [1 ]
Cavalcanti, Gustavo O. [1 ]
Feitosa, Marcilio A. F. [1 ]
Dias Filho, Roberto F. F. [1 ]
Pereira, Alex C. [2 ]
Jatoba, Eduardo B. [2 ]
de Melo Filho, Jose Bione [2 ]
Marinho, Manoel H. N. [1 ]
Converti, Attilio [3 ]
Gomez-Malagon, Luis A. [1 ]
机构
[1] Univ Pernambuco, Polytech Sch Pernambuco, Dept Syst Engn, Postgrad Program Syst Engn, BR-50720001 Recife, PE, Brazil
[2] Sao Francisco Hydroelect Co Chesf, BR-50761901 Recife, PE, Brazil
[3] Univ Genoa, Dept Civil Chem & Environm Engn, Pole Chem Engn, Via Opera Pia 15, I-16145 Genoa, Italy
关键词
auxiliary systems; battery management systems; microgrids; photovoltaic systems; substation; WIND HYBRID SYSTEM; PV-BATTERY SYSTEMS; MULTIOBJECTIVE OPTIMIZATION; DESIGN; CAPACITY;
D O I
10.3390/en16135165
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Electric substations (ESS) are important facilities that must operate even under contingency to guarantee the electrical system's performance. To achieve this goal, the Brazilian national electricity system operator establishes that alternating current (AC) auxiliary systems of ESS must have, at least, two power supplies, and in the case of failure of these sources, an emergency generator (EG) must at least supply energy to the essential loads. In order to improve the availability of auxiliary systems, a microgrid with other sources, such as photovoltaic (PV) systems and Battery Energy Storage Systems (BESS), can be an alternative. In this case, an economical optimization of the PV/BESS system must be addressed considering the costs associated with the installation and maintenance of equipment, and the gains from the credits generated by the photovoltaic system in the net metering scheme. In this paper, the size of the BESS system was determined to supply energy to the load of auxiliary systems of an ESS, as well as a PV system to achieve a null total cost. Furthermore, multi-objective optimization using the genetic algorithm technique was employed to optimize the size of the hybrid PV/BESS to minimize the investment cost and time when the demand was not met. Simulations under different scenarios of contingency were allowed to obtain the Pareto frontier for the optimal sizing of a PV/BESS system to supply energy to AC auxiliary systems in an ESS under contingency.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] Design Considerations of Ultracapacitor Stack for Optimal Sizing of Energy Storage Systems in Contingency Applications
    Roja, P.
    Venkatramanan, D.
    John, Vinod
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2020, 56 (06) : 6803 - 6814
  • [32] Effects of electric vehicles on energy sharing for optimal sizing of solar PV and battery energy storage
    Khanal, Siraj
    Khezri, Rahmat
    Mahmoudi, Amin
    Kahourzadeh, Solmaz
    Aki, Hirohisa
    RENEWABLE ENERGY, 2024, 237
  • [33] Optimal Sizing of Energy Storage for Regenerative Braking in Electric Railway Systems
    de la Torre, Sebastian
    Jose Sanchez-Racero, Antonio
    Antonio Aguado, Jose
    Reyes, Manuel
    Martinez, Oliver
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2015, 30 (03) : 1492 - 1500
  • [34] Optimal sizing of battery energy storage systems and reliability analysis under diverse regulatory frameworks in microgrids
    Gholami, Mohammadreza
    Muyeen, S. M.
    Mousavi, Soad Abokhamis
    ENERGY STRATEGY REVIEWS, 2024, 51
  • [35] Optimal sizing and operation of hybrid energy storage systems in co-phase traction power supply system considering battery degradation
    Gao, Shengfu
    Li, Qunzhan
    Huang, Xiaohong
    Ma, Qingan
    Liu, Wei
    Tang, Sida
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2023, 17 (09) : 2038 - 2054
  • [36] Auxiliary power supply system of passenger train based on photovoltaic and energy storage
    Ma Wei
    Wang Wei
    Hu Ruonan
    Wang Ziyi
    PROCEEDINGS OF THE 2016 IEEE 11TH CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA), 2016, : 784 - 788
  • [37] Optimal Sizing and Energy Management of Battery Energy Storage Systems for Hybrid Offshore Farms
    Varotto, Sofia
    Trovato, Vincenzo
    Kazemi-Robati, Ehsan
    Silva, Bernardo
    2024 IEEE 22ND MEDITERRANEAN ELECTROTECHNICAL CONFERENCE, MELECON 2024, 2024, : 390 - 395
  • [38] Optimal sizing of battery energy storage system for local multi-energy systems: The impact of the thermal vector
    Gluecker, Philipp
    Pesch, Thiemo
    Benigni, Andrea
    APPLIED ENERGY, 2024, 372
  • [39] Power system frequency stability using optimal sizing and placement of Battery Energy Storage System under uncertainty
    Alsharif, Hassan
    Jalili, Mahdi
    Hasan, Kazi N.
    JOURNAL OF ENERGY STORAGE, 2022, 50
  • [40] A Binary Search Algorithm based Optimal Sizing of Photovoltaic and Energy Storage Systems
    Debnath, Anjan
    Olowu, Temitayo O.
    Parvez, Imtiaz
    Sarwat, Arif
    2021 13TH ANNUAL IEEE GREEN TECHNOLOGIES CONFERENCE GREENTECH 2021, 2021, : 563 - 568