Radiologists' performance in reading digital breast tomosynthesis with and without synthesized views for cancer detection

被引:0
|
作者
Trieu, Phuong Dung [1 ]
Noakes, Jennie [1 ,2 ]
Li, Tong [1 ]
Borecky, Natacha [1 ,3 ]
Brennan, Patrick C. [1 ]
Barron, Melissa L. [1 ]
Lewis, Sarah J. [1 ]
机构
[1] Univ Sydney, Fac Med & Hlth, Discipline Med Imaging Sci, Camperdown, NSW, Australia
[2] BreastScreen New South Wales, Level 6,Community Serv Bldg,Herbert St, St Leonards, NSW, Australia
[3] BreastScreen New South Wales North Coast, POB 1098, Lismore, NSW, Australia
来源
BRITISH JOURNAL OF RADIOLOGY | 2023年 / 96卷 / 1145期
关键词
RECONSTRUCTED PROJECTION IMAGES; MAMMOGRAPHY; POPULATION; DBT;
D O I
10.1259/bjr.20220704
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The study aims to evaluate the diagnostic efficacy of radiologists and radiology trainees in digital breast tomosynthesis (DBT) alone vs DBT plus synthe-sized view (SV) for an understanding of the adequacy of DBT images to identify cancer lesions.Methods: Fifty -five observers (30 radiologists and 25 radiology trainees) participated in reading a set of 35 cases (15 cancer) with 28 readers reading DBT and 27 readers reading DBT plus SV. Two groups of readers had similar experience in interpreting mammograms. The performances of participants in each reading mode were compared with the ground truth and calculated in term of specificity, sensitivity, and ROC AUC. The cancer detection rate in various levels of breast density, lesion types and lesion sizes between 'DBT' and 'DBT + SV' were also analyzed. The difference in diagnostic accuracy of readers between two reading modes was assessed using Man-Whitney U test. p < 0.05 indicated a significant result.Results: There was no significant difference in specificity (0.67-vs-0.65; p = 0.69), sensitivity (0.77-vs-0.71; p = 0.09), ROC AUC (0.77-vs-0.73; p = 0.19) of radiologists reading DBT plus SV compared with radiologists reading DBT. Similar result was found in radiology trainees with no significant difference in specificity (0.70-vs-0.63; p = 0.29), sensitivity (0.44-vs-0.55; p = 0.19), ROC AUC (0.59-vs-0.62; p = 0.60) between two reading modes. Radiologists and trainees obtained similar results in two reading modes for cancer detection rate with different levels of breast density, cancer types and sizes of lesions (p > 0.05).Conclusion: Findings show that the diagnostic perfor-mances of radiologists and radiology trainees in DBT alone and DBT plus SV were equivalent in identifying cancer and normal cases. Advances in knowledge: DBT alone had equivalent diag-nostic accuracy as DBT plus SV which could imply the consideration of using DBT as a sole modality without SV.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] A COMPARISON OF DIGITAL BREAST TOMOSYNTHESIS AND FULL FIELD DIGITAL MAMMOGRAPHY IN THE DETECTION OF BREAST CANCER
    Moradzadeh, A.
    Bassett, L. W.
    JOURNAL OF INVESTIGATIVE MEDICINE, 2013, 61 (01) : 128 - 128
  • [22] Comparison of Digital Breast Tomosynthesis and Digital Mammography for Detection of Breast Cancer in Kuwaiti Women
    Asbeutah, Akram M.
    Karmani, Nouralhuda
    Asbeutah, AbdulAziz A.
    Echreshzadeh, Yasmin A.
    AlMajran, Abdullah A.
    Al-Khalifah, Khalid H.
    MEDICAL PRINCIPLES AND PRACTICE, 2019, 28 (01) : 10 - 15
  • [23] Breast cancer screening with digital breast tomosynthesis: Is independent double reading still required?
    Weigel, Stefanie
    Hense, Hans-Werner
    Weyer-Elberich, Veronika
    Gerss, Joachim
    Heindel, Walter
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2024, 196 (08): : 834 - 842
  • [24] Patterns in the Use and Perception of Digital Breast Tomosynthesis: A Survey of Korean Breast Radiologists
    Chae, Eun Young
    Cha, Joo Hee
    Shin, Hee Jung
    Choi, Woo Jung
    Kim, Jihye
    Kim, Sun Mi
    Kim, Hak Hee
    JOURNAL OF THE KOREAN SOCIETY OF RADIOLOGY, 2022, 83 (06): : 1327 - 1341
  • [25] Breast cancer detection: radiologists' performance using mammography with and without automated whole-breast ultrasound
    Kelly, Kevin M.
    Dean, Judy
    Lee, Sung-Jae
    Comulada, W. Scott
    EUROPEAN RADIOLOGY, 2010, 20 (11) : 2557 - 2564
  • [26] Breast cancer detection: radiologists’ performance using mammography with and without automated whole-breast ultrasound
    Kevin M. Kelly
    Judy Dean
    Sung-Jae Lee
    W. Scott Comulada
    European Radiology, 2010, 20 : 2557 - 2564
  • [27] Utilizing Digital Breast Tomosynthesis Projection Views Correlation for Microcalcification Enhancement for Detection Purposes
    Baddar, Wissam J.
    Kim, Eun Joon
    Kim, Dae Hoe
    Ro, Yong Man
    MEDICAL IMAGING 2015: COMPUTER-AIDED DIAGNOSIS, 2015, 9414
  • [28] Detection of masses in digital breast tomosynthesis mammography: Effects of the number of projection views and dose
    Chan, Heang-Ping
    Wei, Jun
    Zhang, Yiheng
    Sahiner, Berkman
    Hadjiiski, Lubomir
    Helvie, Mark A.
    DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2008, 5116 : 279 - 285
  • [29] Synthesized Mammography: The New Standard of Care When Screening for Breast Cancer with Digital Breast Tomosynthesis?
    Ambinder, Emily B.
    Harvey, Susan C.
    Panigrahi, Babita
    Li, Ximin
    Woods, Ryan W.
    ACADEMIC RADIOLOGY, 2018, 25 (08) : 973 - 976
  • [30] Improved detection with digital breast tomosynthesis
    Focusing on industry and technology trends, Brooklyn, NY, United States
    Sci. Comput., 2007, 4 (27-29):