Reproducibility of transthoracic 3D echocardiography in the assessment of mitral valve area in patients with rheumatic mitral stenosis: real time versus ECG-gated 3D echocardiography

被引:2
|
作者
Bouchahda, Nidhal [1 ]
Jarraya, Marwa [1 ]
Kallala, Yessine [1 ]
Sassi, Ghada [1 ]
Boussaada, Mehdi [1 ]
Bader, Mouna [1 ]
Mahjoub, Marwen [1 ]
Haj, Hassen [3 ]
Zemni, Imen [2 ]
Betbout, Fethi [1 ]
Gamra, Habib [1 ]
Hassine, Majed [1 ]
Ben Messaoud, Mejdi [1 ]
机构
[1] Univ Monastir, Bourguiba Univ Hosp, Cardiol Dept A, Res Lab LR12 SP 16,Fattouma, Rue 1Er Juin 1955, Monastir 5000, Tunisia
[2] Univ Monastir, Fac Med, Dept prevent Med, Rue Avicenne, Monastir 5019, Tunisia
[3] TAHER SFAR Univ Hosp, Cardiol Dept, Mahdia 5100, Tunisia
来源
关键词
Mitral valve stenosis; Echocardiography; Four-Dimensional; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; EAE/ASE RECOMMENDATIONS; RECENT PUBLICATION; PRACTICAL GUIDE; STANDARD ERROR; RELIABILITY; VARIABILITY; INTERRATER;
D O I
10.1007/s10554-023-02939-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To assess reproducibility of Real time 3D echocardiography (RT3D) and ECG-gated 3D echocardiography (EG3D) when measuring the mitral valve area (MVA) in rheumatic mitral stenosis (MS). Methods: MVA was assessed by three operators in 68 MS patients using RT3D and EG3D. Reproducibility of each technique was determined by calculating the standard error of measurements (SEM). Results: SEM was similar between RT3D and EG3D. MVA variability was of 0.4 cm(2) or 30% of any RT3D or EG3D measured MVA. The minimal change in MVA above which two measurements should be considered to differ significantly for the same operator was of 0.4 cm(2) for RT3D and 0.5 cm(2) for EG3D. For two different operators making successive measurements, the minimum significant change was of 0.5 cm(2) for RT3D and 0.6 cm(2) for EG3D. The minimum significant difference when switching from RT3D to EG3D or vice versa is of 0.6 cm(2). Low temporal resolution of 6 Hz has the least variability when using RT3D (0.19 cm(2) vs. 0.26 cm(2), p = 0.009) but significantly underestimated MVA (1.3 +/- 0.4 cm(2) vs. 1.4 +/- 0.4 cm(2), p < 10- 3) when compared to EG3D. MVA variability was significantly higher in mild MS when compared to severe MS whether it is RT3D (0.23 cm(2) vs. 0.18 cm(2), p = 0.02) or EG3D (0.27 cm(2) vs. 0.16 cm(2), p < 0.001). Conclusion: RT3D and EG3D are equally reproducible in the assessment of MVA in patients with MS. Further measurements standardization is required to have a clinically acceptable estimations of the true 3D MVA and minimal detectable differences.
引用
收藏
页码:2419 / 2426
页数:8
相关论文
共 50 条
  • [31] Multiplanar visualization in 3D transthoracic echocardiography for precise delineation of mitral valve pathology
    Liang, David
    Paloma, Allan
    Kuppahally, Suman S.
    Miller, D. Craig
    Schnittger, Ingela
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2008, 25 (01): : 84 - 87
  • [32] Isolated anterior mitral valve leaflet cleft: The usefulness of 3D transthoracic echocardiography
    Hammad, Basma
    Hay, Mohamed Ayman Abdel
    EGYPTIAN HEART JOURNAL, 2016, 68 (04): : 283 - 285
  • [33] Qualitative and quantitative assessment of mitral regurgitation by real-time 3D echocardiography
    Kapetanakis, S
    Corrigan, N
    DeGuzman, J
    Owen, S
    Murray, O
    Monaghan, MJ
    HEART, 2004, 90 : 31 - 31
  • [34] MITRAL ANNULAR SIZE BY 3D TRANSTHORACIC ECHOCARDIOGRAPHY VERSUS CARDIAC COMPUTED TOMOGRAPHY
    Peters, Matthew
    Tanel, Emily
    Marzlin, Nathan
    Kroboth, Stacie
    Kanani, Jim
    Bajwa, Tanvir
    Allaqaband, Suhail
    Weiss, Eric
    Harland, Daniel
    Jain, Renuka
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 83 (13) : 1426 - 1426
  • [35] Direct planimetry of mitral valve regurgitation orifice area by real-time 3D transesophageal echocardiography
    Altiok, E.
    Hamada, S.
    Van Hall, S.
    Hanenberg, M.
    Grabskaya, E.
    Becker, M.
    Marx, N.
    Hoffmann, R.
    EUROPEAN HEART JOURNAL, 2010, 31 : 4 - 4
  • [36] Calcific extension towards the mitral valve causes non-rheumatic mitral stenosis in degenerative aortic stenosis: real-time 3D transoesophageal echocardiography study
    Iwataki, Mai
    Takeuchi, Masaaki
    Otani, Kyoko
    Kuwaki, Hiroshi
    Yoshitani, Hidetoshi
    Abe, Haruhiko
    Lang, Roberto M.
    Levine, Robert A.
    Otsuji, Yutaka
    OPEN HEART, 2014, 1 (01):
  • [37] Should mitral valve area assessment in patients with mitral stenosis be based on anatomical or on functional evaluation? A plea for 3D echocardiography as the new clinical standard
    Mannaerts, HFJ
    Kamp, O
    Visser, CA
    EUROPEAN HEART JOURNAL, 2004, 25 (23) : 2073 - 2074
  • [38] Mitral valve prolapse: role of 3D echocardiography in diagnosis
    Benenstein, Ricardo
    Saric, Muhamed
    CURRENT OPINION IN CARDIOLOGY, 2012, 27 (05) : 465 - 476
  • [39] Localizing Mitral Valve Perforations With 3D Transesophageal Echocardiography
    Bhave, Nicole M.
    Addetia, Karima
    Spencer, Kirk T.
    Weinert, Lynn
    Jeevanandam, Valluvan
    Lang, Roberto M.
    JACC-CARDIOVASCULAR IMAGING, 2013, 6 (03) : 407 - 410
  • [40] Cleft in the Anterior Mitral Valve Leaflet Assessed by Real-time 3D Echocardiography
    Bezgin, Tahir
    Dogan, Cem
    Karagoz, Ali
    Elveran, Ali
    Kaymaz, Cihangir
    INTERNATIONAL CARDIOVASCULAR RESEARCH JOURNAL, 2016, 10 (02) : 99 - 101