Reproducibility of transthoracic 3D echocardiography in the assessment of mitral valve area in patients with rheumatic mitral stenosis: real time versus ECG-gated 3D echocardiography

被引:2
|
作者
Bouchahda, Nidhal [1 ]
Jarraya, Marwa [1 ]
Kallala, Yessine [1 ]
Sassi, Ghada [1 ]
Boussaada, Mehdi [1 ]
Bader, Mouna [1 ]
Mahjoub, Marwen [1 ]
Haj, Hassen [3 ]
Zemni, Imen [2 ]
Betbout, Fethi [1 ]
Gamra, Habib [1 ]
Hassine, Majed [1 ]
Ben Messaoud, Mejdi [1 ]
机构
[1] Univ Monastir, Bourguiba Univ Hosp, Cardiol Dept A, Res Lab LR12 SP 16,Fattouma, Rue 1Er Juin 1955, Monastir 5000, Tunisia
[2] Univ Monastir, Fac Med, Dept prevent Med, Rue Avicenne, Monastir 5019, Tunisia
[3] TAHER SFAR Univ Hosp, Cardiol Dept, Mahdia 5100, Tunisia
来源
关键词
Mitral valve stenosis; Echocardiography; Four-Dimensional; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; EAE/ASE RECOMMENDATIONS; RECENT PUBLICATION; PRACTICAL GUIDE; STANDARD ERROR; RELIABILITY; VARIABILITY; INTERRATER;
D O I
10.1007/s10554-023-02939-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To assess reproducibility of Real time 3D echocardiography (RT3D) and ECG-gated 3D echocardiography (EG3D) when measuring the mitral valve area (MVA) in rheumatic mitral stenosis (MS). Methods: MVA was assessed by three operators in 68 MS patients using RT3D and EG3D. Reproducibility of each technique was determined by calculating the standard error of measurements (SEM). Results: SEM was similar between RT3D and EG3D. MVA variability was of 0.4 cm(2) or 30% of any RT3D or EG3D measured MVA. The minimal change in MVA above which two measurements should be considered to differ significantly for the same operator was of 0.4 cm(2) for RT3D and 0.5 cm(2) for EG3D. For two different operators making successive measurements, the minimum significant change was of 0.5 cm(2) for RT3D and 0.6 cm(2) for EG3D. The minimum significant difference when switching from RT3D to EG3D or vice versa is of 0.6 cm(2). Low temporal resolution of 6 Hz has the least variability when using RT3D (0.19 cm(2) vs. 0.26 cm(2), p = 0.009) but significantly underestimated MVA (1.3 +/- 0.4 cm(2) vs. 1.4 +/- 0.4 cm(2), p < 10- 3) when compared to EG3D. MVA variability was significantly higher in mild MS when compared to severe MS whether it is RT3D (0.23 cm(2) vs. 0.18 cm(2), p = 0.02) or EG3D (0.27 cm(2) vs. 0.16 cm(2), p < 0.001). Conclusion: RT3D and EG3D are equally reproducible in the assessment of MVA in patients with MS. Further measurements standardization is required to have a clinically acceptable estimations of the true 3D MVA and minimal detectable differences.
引用
收藏
页码:2419 / 2426
页数:8
相关论文
共 50 条
  • [11] Role of real time 3D echocardiography in the assessment of mitral valve area during pecutaneous balloon mitral valvuloplasty
    Cordeiro, P
    Zamorano, J
    de Isla, LP
    Gutierrez-Chico, JL
    Almería, C
    Rodrigo, JL
    Hernández-Antolín, R
    Macaya, C
    EUROPEAN HEART JOURNAL, 2004, 25 : 270 - 270
  • [12] Mitral valve rheumatic multiple fenestrations: usefulness of 3D real-time echocardiography
    D'Aloia, Antonio
    Vizzardi, Enrico
    Rovetta, Riccardo
    Bugatti, Silvia
    Bonadei, Ivano
    Curnis, Antonio
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2015, 16 : S98 - S99
  • [13] 3D quantitation of mitral valve coaptation by novel software system with transthoracic real-time 3D echocardiography
    Tsukiji, Miwako
    Watanabe, Nozomi
    Yamaura, Yasuko
    Okahashi, Noriko
    Okura, Hiroyuki
    Ogasawara, Yasuo
    Yoshida, Kiyoshi
    CIRCULATION, 2006, 114 (18) : 716 - 717
  • [14] STUDYING THE ROLE OF 3D TRANSTHORACIC ECHOCARDIOGRAPHY FOR THE EVALUATION OF RHEUMATIC MITRAL STENOSIS COMPARE TO 2D TRANSESOPHAGEAL ECHOCARDIOGRAPHY
    Phan Thai Hao
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (09) : 1601 - 1601
  • [15] Mitral valve regurgitation and 3D echocardiography
    Zakkar, Mustafa
    Patni, Ravi
    Punjabi, Prakash P.
    FUTURE CARDIOLOGY, 2010, 6 (02) : 231 - 242
  • [16] 3D echocardiography in mitral valve prolapse
    Mantegazza, Valentina
    Gripari, Paola
    Tamborini, Gloria
    Muratori, Manuela
    Fusini, Laura
    Ali, Sarah Ghulam
    Garlasche, Anna
    Pepi, Mauro
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 9
  • [17] Fully Automatic Assessment of Mitral Valve Morphology from 3D Transthoracic Echocardiography
    Pedrosa, Joao
    Queiros, Sandro
    Vilaca, Joao
    Badano, Luigi
    D'hooge, Jan
    2018 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2018,
  • [18] MEASUREMENT OF THREE-DIMENSIONAL (3D) MITRAL VALVE AREA IN PATIENTS WITH MITRAL ANNULAR CALCIFICATION BY TRANSTHORACIC ECHOCARDIOGRAPHY
    Gupta, Aashish
    Okor, Ivana
    Kachur, Sergey
    Kadakia, Rikin
    Stone, Michael
    Morris, Jessica
    Morin, Daniel
    Gilliland, Yvonne
    Pressman, Gregg
    Qamruddin, Salima
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 77 (18) : 1348 - 1348
  • [19] Advances in 3D echocardiography for mitral valve
    Qamruddin, Salima
    Naqvi, Tasneem Z.
    EXPERT REVIEW OF CARDIOVASCULAR THERAPY, 2011, 9 (11) : 1431 - 1443
  • [20] Assessment of the mitral valve annulus by 3D echocardiography in children
    Cardin, C.
    Arnaudis, B.
    Hascoet, S.
    Amadieu, R.
    Seguela, P. E.
    Dulac, Y.
    Leobon, B.
    Acar, P.
    EUROPEAN HEART JOURNAL, 2010, 31 : 184 - 184