The influence of different versions of FLUKA and GEANT4 on the calculation of response functions of ionization chambers in clinical proton beams

被引:1
|
作者
Baumann, Kilian-Simon [1 ,2 ,3 ]
Derksen, Larissa [2 ]
Witt, Matthias [2 ,3 ]
Adeberg, Sebastian [1 ,3 ,4 ]
Zink, Klemens [1 ,2 ,3 ]
机构
[1] Univ Med Ctr Giessen Marburg, Dept Radiotherapy & Radiooncol, Marburg, Germany
[2] Univ Appl Sci, Inst Med Phys & Radiat Protect, Giessen, Germany
[3] Marburg Ion Beam Therapy Ctr MIT, Marburg, Germany
[4] Univ Ctr Tumorerkrankungen UCT Frankfurt Marburg, Frankfurt, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2023年 / 68卷 / 24期
关键词
proton reference dosimetry; proton therapy; response functions; Monte Carlo; FLUKA; Geant4; TOPAS; QUALITY CORRECTION FACTORS; MONTE-CARLO CALCULATION; SIMULATION; DOSIMETRY;
D O I
10.1088/1361-6560/ad0ad4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. To investigate the influence of different versions of the Monte Carlo codes geant4 and fluka on the calculation of overall response functions f(Q) of air-filled ionization chambers in clinical proton beams. Approach. f(Q) factors were calculated for six plane-parallel and four cylindrical ionization chambers with geant4 and fluka. These factors were compared to already published values that were derived using older versions of these codes. Main results. Differences in f(Q) factors calculated with different versions of the same Monte Carlo code can be up to similar to 1%. Especially for geant4, the updated version leads to a more pronounced dependence of f(Q) on proton energy and to smaller f(Q) factors for high energies. Significance. Different versions of the same Monte Carlo code can lead to differences in the calculation of f(Q) factors of up to similar to 1% without changing the simulation setup, transport parameters, ionization chamber geometry modeling, or employed physics lists. These findings support the statement that the dominant contributor to the overall uncertainty of Monte Carlo calculated f(Q) factors are type-B uncertainties.
引用
收藏
页数:11
相关论文
共 17 条
  • [1] Monte Carlo Calculation of Perturbation Correction Factors for AirFilled Ionization Chambers in Clinical Proton Beams Using TOPAS/GEANT4
    Baumann, K.
    Kaupa, S.
    Engenhart-Cabillic, R.
    Zink, K.
    MEDICAL PHYSICS, 2020, 47 (06) : E281 - E282
  • [2] Comparison of PENH, FLUKA and Geant4/TOPAS for radiation transport calculations in proton beams
    Baumann, K.
    Horst, F.
    Zink, K.
    Goma, C.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S148 - S148
  • [3] Comparison of penh, fluka, and Geant4/topas for absorbed dose calculations in air cavities representing ionization chambers in high-energy photon and proton beams
    Baumann, Kilian-Simon
    Horst, Felix
    Zink, Klemens
    Goma, Carles
    MEDICAL PHYSICS, 2019, 46 (10) : 4639 - 4653
  • [4] TOPAS/Geant4 configuration for ionization chamber calculations in proton beams
    Wulff, Joerg
    Baumann, Kilian-Simon
    Verbeek, Nico
    Baeumer, Christian
    Timmermann, Beate
    Zink, Klemens
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (11):
  • [5] Calculation of the Interference Factors of air-filled Ionization Chambers in clinical Proton Fields with the Monte Carlo Code Geant4 / TOPAS
    Baumann, K. -S
    Kaupa, S.
    Bach, C.
    Engenhart-Cabillic, R.
    Zink, K.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2020, 196 (SUPPL 1) : S207 - S208
  • [6] Fluence correction factors for graphite calorimetry in clinical proton beams using Geant4
    Shipley, D. R.
    Lourenco, A. M.
    Palmans, H.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S77 - S78
  • [7] Monte Carlo calculation of perturbation correction factors for air-filled ionization chambers in clinical proton beams using TOPAS/GEANT
    Baumann, Kilian-Simon
    Kaupa, Sina
    Bach, Constantin
    Engenhart-Cabillic, Rita
    Zink, Klemens
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2021, 31 (02): : 175 - 191
  • [8] Comparison of the Sensitive Volume Response of the Three Different Cylindrical Ionization Chambers with GEANT4 Simulations Using the Concept of Output Factor
    Ayrancioglu, Oguzhan
    Sisman, Gizem
    Kandemir, Recep
    Ayrancioglu, Ceren
    Akgungor, Kadir
    Alicikus, Lutfiye Zumre A. R. I. C. A. N.
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2024, 39 (01): : 27 - 38
  • [9] TOPAS/Geant4 configuration for ionization chamber calculations in proton beams (vol 63, 115013, 2018)
    Wulff, Joerg
    Baumann, Kilian-Simon
    Verbeek, Nico
    Baeumer, Christian
    Timmermann, Beate
    Zink, Klemens
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (06):
  • [10] Dose calculation accuracy of Gate/Geant4 on transverse dose profiles of proton pencil beams in water
    Resch, A.
    Carlino, A.
    Fuchs, H.
    Elia, A.
    Stock, M.
    Georg, D.
    Grevillot, L.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S970 - S971