Calculation of the Interference Factors of air-filled Ionization Chambers in clinical Proton Fields with the Monte Carlo Code Geant4 / TOPAS

被引:0
|
作者
Baumann, K. -S [1 ,2 ]
Kaupa, S. [2 ]
Bach, C. [2 ]
Engenhart-Cabillic, R. [1 ,3 ]
Zink, K. [1 ,2 ,3 ,4 ]
机构
[1] Univ Klinikum Giessen & Marburg, Klin Strahlentherapie & Radioonkol, Marburg, Germany
[2] Tech Hsch Mittelhessen, Inst Med Phys & Strahlenschutz, Giessen, Germany
[3] Marburger Ionenstrahl Therapiezentrum, Marburg, Germany
[4] Frankfurt Inst Adv Studies FIAS, Frankfurt, Germany
关键词
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
P49-11-jD
引用
收藏
页码:S207 / S208
页数:2
相关论文
共 34 条
  • [1] Monte Carlo calculation of perturbation correction factors for air-filled ionization chambers in clinical proton beams using TOPAS/GEANT
    Baumann, Kilian-Simon
    Kaupa, Sina
    Bach, Constantin
    Engenhart-Cabillic, Rita
    Zink, Klemens
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2021, 31 (02): : 175 - 191
  • [2] Monte Carlo Calculation of Perturbation Correction Factors for AirFilled Ionization Chambers in Clinical Proton Beams Using TOPAS/GEANT4
    Baumann, K.
    Kaupa, S.
    Engenhart-Cabillic, R.
    Zink, K.
    MEDICAL PHYSICS, 2020, 47 (06) : E281 - E282
  • [3] An Overview of Monte Carlo calculated fQ Factors of air-filled Ionization Chambers in clinical Proton Fields
    Baumann, K.
    Goma, C.
    Wulff, J.
    Kretschmer, J.
    Zink, K.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2022, 198 (SUPPL 1) : S173 - S173
  • [4] Monte Carlo calculated radiation quality correction factors for air-filled ionization chambers in modulated proton fields
    Baumann, Kilian-Simon
    Derksen, Larissa
    Flatten, Veronika
    Witt, Matthias
    Engenhart-Cabillic, Rita
    Zink, Klemens
    STRAHLENTHERAPIE UND ONKOLOGIE, 2023, 199 : S45 - S46
  • [5] Monte Carlo calculation of beam quality correction factors in proton beams using TOPAS/GEANT4
    Baumann, Kilian-Simon
    Kaupa, Sina
    Bach, Constantin
    Engenhart-Cabillic, Rita
    Zink, Klemens
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (05):
  • [6] Monte Carlo calculation of beam quality correction factors in proton beams using TOPAS/GEANT4 (vol 65, 055015, 2020)
    Baumann, Kilian-Simon
    Kaupa, Sina
    Bach, Constantin
    Engenhart-Cabillic, Rita
    Zink, Klemens
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (11):
  • [7] The influence of different versions of FLUKA and GEANT4 on the calculation of response functions of ionization chambers in clinical proton beams
    Baumann, Kilian-Simon
    Derksen, Larissa
    Witt, Matthias
    Adeberg, Sebastian
    Zink, Klemens
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (24):
  • [8] Calculation of extrapolation curves in the 4π(LS)β-γ coincidence technique with the Monte Carlo code Geant4
    Bobin, C.
    Thiam, C.
    Bouchard, J.
    APPLIED RADIATION AND ISOTOPES, 2016, 109 : 319 - 324
  • [9] Benchmarking a GATE/Geant4 Monte Carlo model for proton beams in magnetic fields
    Padilla-Cabal, Fatima
    Alejandro Fragoso, Jose
    Resch, Andreas Franz
    Georg, Dietmar
    Fuchs, Hermann
    MEDICAL PHYSICS, 2020, 47 (01) : 223 - 233
  • [10] A Geant4/TOPAS Monte Carlo System for Validating Proton Therapy Treatment Plan Calculations at Mayo Clinic
    Tseung, H. Wan Chan
    Beltran, C.
    MEDICAL PHYSICS, 2013, 40 (06)