DFT and electrochemical determination of Hg2+ and Pb2+ in water using polyaniline-quinoxaline composite modified GCE electrode

被引:4
|
作者
Maheshwaran, Muniyasamy [1 ]
Kumar, Konda Kannan Satheesh [1 ]
机构
[1] Gandhigram Rural Inst Deemed Univ, Dept Chem, Gandhigram 624302, TN, India
关键词
Polyaniline-quinoxaline; Composite; DFT study; Electrochemical sensor; Heavy metal ions; Electrolytic system; GRAPHENE OXIDE; ION; PERFORMANCE; SENSOR; CU2+; CD2+; NANOCOMPOSITE;
D O I
10.1016/j.molliq.2024.124317
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In this study, we designed and synthesized a new class of donor-acceptor conjugated polymers containing the polyaniline-quinoxaline [Acenaptho [1, 2 -b] quinoxalin-9-amine] (PAni-QUA) composite, and we subsequently utilized it as an electrochemical sensor to detect Hg2+ and Pb2+ ions with good selectivity and sensitivity. Energy dispersive X-ray analysis spectroscopy (EDAX), scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FT-IR), and UV-Vis spectroscopy (UV-Vis) were employed to analyze the structural and morphological characteristics of the resulting composite. The electrochemical characteristics of the electrode modifiers were analyzed using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Several sensitivity-influencing factors, including chemical and electrochemical parameters like pH and the impact of the supporting electrolyte medium, were also identified to improve the efficiency of the developed sensor. In the presence of different hazardous metal ion species, the interference ability of the proposed sensor was also examined. They were also used to conduct individual and simultaneous sensing studies of various metal ions in different supportive electrolyte media utilizing the differential pulse voltammetry technique (DPV). The PAni-QUA composite modified GCE sensor shows remarkable selectivity and sensitivity towards Hg2+ and Pb2+ ions over the other heavy metal ions in 1 to 20 mu M ranges, respectively. The detection limits (3 sigma/m) were 1.28 nM and 5.91 nM for Hg2+ and Pb2+ ions. Density Functional Theory (DFT) was used in the present study to accomplish the adsorption mechanism of the suggested sensors. The DFT calculation demonstrated that the PAniQUA composite was formed with a lower band gap energy than QUA and DD PAni. These results showed that the suggested sensor (PAni-QUA) had the lowest detection limit in the acetate buffer medium compared to the specified electrolyte media. Based on these findings, it is possible to use this technology to identify harmful metal ions (Hg2+ and Pb2+) with high sensitivity in real water samples.
引用
收藏
页数:18
相关论文
共 50 条
  • [31] Simultaneous electrochemical determination of Pb2+ and Cd2+ ions in food samples by a silver nanoparticle/COF composite modified glassy carbon electrode
    Sarvestani, Mohammad Reza Jalali
    Madrakian, Tayyebeh
    Afkhami, Abbas
    JOURNAL OF FOOD MEASUREMENT AND CHARACTERIZATION, 2023, 17 (04) : 3505 - 3514
  • [32] Simultaneous electrochemical determination of Pb2+ and Cd2+ ions in food samples by a silver nanoparticle/COF composite modified glassy carbon electrode
    Mohammad Reza Jalali Sarvestani
    Tayyebeh Madrakian
    Abbas Afkhami
    Journal of Food Measurement and Characterization, 2023, 17 : 3505 - 3514
  • [33] Simultaneous electrochemical sensing of heavy metal ions (Zn2+, Cd2+, Pb2+, and Hg2+) in food samples using a covalent organic framework/ carbon black modified glassy carbon electrode
    Karazan, Zahra Mirzaei
    Roushani, Mahmoud
    Hoseini, S. Jafar
    FOOD CHEMISTRY, 2024, 442
  • [34] Simultaneous electrochemical sensing of heavy metal ions (Zn2+, Cd2+, Pb2+, and Hg2+) in food samples using a covalent organic framework/carbon black modified glassy carbon electrode
    Department of Chemistry, Faculty of Sciences, Ilam University, Ilam
    P. O. BOX. 69315-516, Iran
    不详
    7194684795, Iran
    Food Chem.,
  • [35] Electrochemical Redox of Hg2+ Mediated by Activated Carbon Modified Glassy Carbon Electrode
    Radhi, M. M.
    Tan, W. T.
    Ab Rahman, M. Z. B.
    Kassim, A. B.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2010, 5 (05): : 615 - 629
  • [36] A new electrochemical sensor based on carboimidazole grafted reduced graphene oxide for simultaneous detection of Hg2+ and Pb2+
    Xing, Huakun
    Xu, Jingkun
    Zhu, Xiaofei
    Duan, Xuemin
    Lu, Limin
    Zuo, Yinxiu
    Zhang, Youshan
    Wang, Wenmin
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 782 : 250 - 255
  • [37] COFBTLP-1/three-dimensional macroporous carbon electrode for simultaneous electrochemical detection of Cd2+, Pb2+, Cu2+ and Hg2+
    Han, Jiajia
    Yu, Jingguo
    Guo, Yufei
    Wang, Li
    Song, Yonghai
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 321 (321):
  • [38] Water Soluble Cationic Porphyrin Sensor for Detection of Hg2+, Pb2+, Cd2+, and Cu2+
    Zamadar, Matibur
    Orr, Christopher
    Uherek, Miranda
    JOURNAL OF SENSORS, 2016, 2016
  • [39] Practical, highly sensitive, and regenerable evanescent-wave biosensor for detection of Hg2+ and Pb2+ in water
    Han, Shitong
    Zhou, Xiaohong
    Tang, Yunfei
    He, Miao
    Zhang, Xinyu
    Shi, Hanchang
    Xiang, Yu
    BIOSENSORS & BIOELECTRONICS, 2016, 80 : 265 - 272
  • [40] Azido chelating fiber: synthesis, characterization and adsorption performances towards Hg2+ and Pb2+ from water
    Zhang, Like
    Wang, Yanan
    Huang, Jiajia
    Yuan, Siguo
    POLYMERS FOR ADVANCED TECHNOLOGIES, 2017, 28 (11) : 1418 - 1427