DFT and electrochemical determination of Hg2+ and Pb2+ in water using polyaniline-quinoxaline composite modified GCE electrode

被引:4
|
作者
Maheshwaran, Muniyasamy [1 ]
Kumar, Konda Kannan Satheesh [1 ]
机构
[1] Gandhigram Rural Inst Deemed Univ, Dept Chem, Gandhigram 624302, TN, India
关键词
Polyaniline-quinoxaline; Composite; DFT study; Electrochemical sensor; Heavy metal ions; Electrolytic system; GRAPHENE OXIDE; ION; PERFORMANCE; SENSOR; CU2+; CD2+; NANOCOMPOSITE;
D O I
10.1016/j.molliq.2024.124317
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In this study, we designed and synthesized a new class of donor-acceptor conjugated polymers containing the polyaniline-quinoxaline [Acenaptho [1, 2 -b] quinoxalin-9-amine] (PAni-QUA) composite, and we subsequently utilized it as an electrochemical sensor to detect Hg2+ and Pb2+ ions with good selectivity and sensitivity. Energy dispersive X-ray analysis spectroscopy (EDAX), scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FT-IR), and UV-Vis spectroscopy (UV-Vis) were employed to analyze the structural and morphological characteristics of the resulting composite. The electrochemical characteristics of the electrode modifiers were analyzed using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Several sensitivity-influencing factors, including chemical and electrochemical parameters like pH and the impact of the supporting electrolyte medium, were also identified to improve the efficiency of the developed sensor. In the presence of different hazardous metal ion species, the interference ability of the proposed sensor was also examined. They were also used to conduct individual and simultaneous sensing studies of various metal ions in different supportive electrolyte media utilizing the differential pulse voltammetry technique (DPV). The PAni-QUA composite modified GCE sensor shows remarkable selectivity and sensitivity towards Hg2+ and Pb2+ ions over the other heavy metal ions in 1 to 20 mu M ranges, respectively. The detection limits (3 sigma/m) were 1.28 nM and 5.91 nM for Hg2+ and Pb2+ ions. Density Functional Theory (DFT) was used in the present study to accomplish the adsorption mechanism of the suggested sensors. The DFT calculation demonstrated that the PAniQUA composite was formed with a lower band gap energy than QUA and DD PAni. These results showed that the suggested sensor (PAni-QUA) had the lowest detection limit in the acetate buffer medium compared to the specified electrolyte media. Based on these findings, it is possible to use this technology to identify harmful metal ions (Hg2+ and Pb2+) with high sensitivity in real water samples.
引用
收藏
页数:18
相关论文
共 50 条
  • [21] Electrochemical determination of Hg2+ in sakura shrimp and drinking water using f-CNF/TeO2 composite
    Narasimha Murthy Umesh
    Sea-Fue Wang
    Karuppasamy Kohila Rani
    Wei-Chih Pan
    Journal of Materials Science: Materials in Electronics, 2020, 31 : 12973 - 12982
  • [22] Simultaneous Determination of Cd2+, Pb2+, Cu2+ and Hg2+ at a Carbon Paste Electrode Modified with Ionic Liquid-functionalized Ordered Mesoporous Silica
    Zhang, Penghui
    Dong, Sheying
    Gu, Guangzhe
    Huang, Tinglin
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2010, 31 (10): : 2949 - 2954
  • [23] Determination of Pb2+ in water using poly(pyrrole thiourea) electrode coupled with an electrochemical flow analysis device
    Lai, Zhiwei
    Zhang, Guiyun
    Chen, Xi
    ELECTROANALYSIS, 2024, 36 (05)
  • [24] Simultaneous detection of Pb2+, Cu2+ and Hg2+ by differential pulse voltammetry at an indium tin oxide glass electrode modified by hydroxyapatite
    Sun, Mingxu
    Li, Ziheng
    Wu, Shuang
    Gu, Yuwei
    Li, Yuying
    ELECTROCHIMICA ACTA, 2018, 283 : 1223 - 1230
  • [25] Fluorescent detection of Hg2+ and Pb2+ using GeneFinder™ and an integrated functional nucleic acid
    Zhan, Shenshan
    Xu, Hanchu
    Zhang, Dongwei
    Xia, Bing
    Zhan, Xuejia
    Wang, Lumei
    Lv, Jing
    Zhou, Pei
    BIOSENSORS & BIOELECTRONICS, 2015, 72 : 95 - 99
  • [26] Electrochemical evaluation of Cd2+ and Hg2+ ions in water using ZnO/Cu2ONPs/PANI modified SPCE electrode
    Okpara, Enyioma C.
    Fayemi, Omolola E.
    Sherif, El-Sayed M.
    Ganesh, Pattan S.
    Swamy, B. E. Kumara
    Ebenso, Eno E.
    SENSING AND BIO-SENSING RESEARCH, 2022, 35
  • [27] Solvothermal method synthesized SnS nanoplates composites for electrochemical sensing of toxic ions Hg2+ and Pb2+
    Talapatadur, Vijaya
    Hegde, S. S.
    Basavaraju, N.
    Ramesh, K.
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2025, 22 (01) : 231 - 242
  • [28] Determination of Hg2+ on poly(vinylferrocenium) (PVF+)-modified platinum electrode
    Celebi, Mutlu Soenmez
    Ozyoruk, Haluk
    Yildiz, Attila
    Abaci, Serdar
    TALANTA, 2009, 78 (02) : 405 - 409
  • [29] Electrochemical determination of Pb2+ and Cd2+ with a poly(pyrrole-1-carboxylic acid) modified electrode
    Poudel, Abiral
    Sunder, Govind Sharma Shyam
    Rohanifar, Ahmad
    Adhikari, Sandhya R.
    Kirchhoff, Jon
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2022, 911
  • [30] Determination of Cd2+ and Pb2+ on glassy carbon electrode modified by electrochemical reduction of aromatic diazonium salts
    Fan, Lishuang
    Chen, Jiuan
    Zhu, Shuyun
    Wang, Min
    Xu, Guobao
    ELECTROCHEMISTRY COMMUNICATIONS, 2009, 11 (09) : 1823 - 1825