Influence of intraoral conditions on the accuracy of digital and conventional implant impression techniques for two-implant-supported fixed dental prostheses

被引:9
|
作者
Ma, Yun [1 ,2 ]
Guo, Yong-qing [3 ,4 ]
Jiang, Lei [1 ,2 ,3 ,4 ]
Yu, Hao [1 ,2 ,3 ,4 ,5 ,6 ]
机构
[1] Fujian Med Univ, Fujian Key Lab Oral Dis, Fuzhou, Peoples R China
[2] Fujian Med Univ, Sch & Hosp Stomatol, Fujian Prov Engn Res Ctr Oral Biomat & Stomatol Ke, Fujian Coll & Univ, Fuzhou, Peoples R China
[3] Fujian Med Univ, Dept Prosthodont, Fuzhou, Peoples R China
[4] Fujian Med Univ, Res Ctr Dent Esthet & Biomech, Fuzhou, Peoples R China
[5] Nagasaki Univ, Grad Sch Biomed Sci, Dept Appl Prosthodont, Nagasaki, Japan
[6] Fujian Med Univ, Sch & Hosp Stomatol, Dept Prosthodont, Yangqiao Zhong Rd 246, Fuzhou, Peoples R China
关键词
Accuracy; Intraoral conditions; Dental implant; Dental impression technique; Intraoral scanner; IN-VIVO PRECISION; 3-DIMENSIONAL ACCURACY; IMPACT; VITRO;
D O I
10.2186/jpr.JPR_D_22_00242
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To compare the trueness and precision of different impression techniques for two-implant-supported fixed dental prostheses between extraoral and intraoral conditions at different locations.Methods: Six volunteers participated in this study. A resin block with two parallel analogs was fabricated as an implant site simulator (ISS). The ISS was bonded to a molded ethylene vinyl acetate sheet to create a reference model. For each participant, four reference models were prepared based on the locations of the ISSs: maxillary posterior/anterior region (MaxP/MaxA) and mandibular posterior/anterior region (ManP/ManA). Five impressions were taken extraorally using the open-tray (conventional implant impression technique, CIT) and intraoral scanning (digital implant impression technique, DIT) techniques. The reference models were positioned in the participants' mouths, and impressions were obtained intraorally using the CIT and DIT. The interanalog distance (d) and angulation (theta) were measured to calculate trueness (Delta d, Delta theta) and precision (dP, theta P). Two-way ANOVA and t tests were performed (alpha=0.05).Results: For the DIT, under intraoral conditions, the Delta d and Delta theta in MaxP and Delta theta in ManP were significantly higher than those under extraoral conditions. For the CIT, under intraoral conditions, the Delta d and Delta theta in ManA and ManP and Delta theta in MaxP were significantly lower than those under extraoral conditions. No significant differences in the dP and theta P of either DIT or CIT were observed between the two conditions.Conclusions: Intraoral conditions affected the trueness of DIT and CIT in different regions but had no influence on precision.
引用
收藏
页码:633 / 640
页数:8
相关论文
共 50 条
  • [41] Conventional and digital impressions for complete-arch implant-supported fixed prostheses: time, implant quantity effect and patient satisfaction
    Pereira, Ana Larisse Carneiro
    Medeiros, Vitoria Ramos
    Campos, Maria de Fatima Trindade Pinto
    de Medeiros, Annie Karoline Bezerra
    Yilmaz, Burak
    Carreiro, Adriana da Fonte Porto
    JOURNAL OF ADVANCED PROSTHODONTICS, 2022, 14 (04): : 212 - 222
  • [42] Accuracy of photogrammetry, intraoral scanning, and conventional impression techniques for complete-arch implant rehabilitation: an in vitro comparative study
    Ma, Bowen
    Yue, Xinxin
    Sun, Yujie
    Peng, Lingyan
    Geng, Wei
    BMC ORAL HEALTH, 2021, 21 (01)
  • [43] Accuracy of photogrammetry, intraoral scanning, and conventional impression techniques for complete-arch implant rehabilitation: an in vitro comparative study
    Bowen Ma
    Xinxin Yue
    Yujie Sun
    Lingyan Peng
    Wei Geng
    BMC Oral Health, 21
  • [44] Accuracy of Conventional and Digital Impressions for Full-Arch Implant-Supported Prostheses: An In Vitro Study
    Drancourt, Noemie
    Auduc, Chantal
    Mouget, Aymeric
    Mouminoux, Jean
    Auroy, Pascal
    Veyrune, Jean-Luc
    El Osta, Nada
    Nicolas, Emmanuel
    JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (05):
  • [45] Accuracy of digital impressions for three- unit and four-unit implant supported fixed dental prostheses using a novel device
    Kao, Tzu-Yung
    Hsieh, Min-Chieh
    Liao, Chi -Chun
    Chang, Chih-Ling
    JOURNAL OF DENTAL SCIENCES, 2023, 18 (02) : 702 - 708
  • [46] Accuracy of digital and conventional dental implant impressions for fixed partial dentures: A comparative clinical study
    Gedrimiene, Agne
    Adaskevicius, Rimas
    Rutkunas, Vygandas
    JOURNAL OF ADVANCED PROSTHODONTICS, 2019, 11 (05): : 271 - 279
  • [47] Comparison of the Clinical Accuracy of Digital and Conventional Dental Implant Impressions
    Rutkunas, Vygandas
    Gedrimiene, Agne
    Adaskevicius, Rimas
    Husain, Nadin Al-Haj
    Ozcan, Mutlu
    EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2020, 28 (04): : 173 - 181
  • [48] A Clinical Comparative Study of 3-Dimensional Accuracy between Digital and Conventional Implant Impression Techniques
    Alsharbaty, Mohammed Hussein M.
    Alikhasi, Marzieh
    Zarrati, Simindokht
    Shamshiri, Ahmed Reza
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (04): : E902 - E908
  • [49] Digital Evaluation of the Dimensional Accuracy of Four Different Implant Impression Techniques
    Ozcelik, T. B.
    Ozcan, I.
    Ozan, O.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2018, 21 (10) : 1247 - 1253
  • [50] Static and Fatigue Loading of Veneered Implant-Supported Fixed Dental Prostheses
    Rayyan, Mohammad M.
    Abdallah, Jihad
    Segaan, Lucette G.
    Bonfante, Estevam A.
    Osman, Essam
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2020, 29 (08): : 679 - 685