Influence of intraoral conditions on the accuracy of digital and conventional implant impression techniques for two-implant-supported fixed dental prostheses

被引:9
|
作者
Ma, Yun [1 ,2 ]
Guo, Yong-qing [3 ,4 ]
Jiang, Lei [1 ,2 ,3 ,4 ]
Yu, Hao [1 ,2 ,3 ,4 ,5 ,6 ]
机构
[1] Fujian Med Univ, Fujian Key Lab Oral Dis, Fuzhou, Peoples R China
[2] Fujian Med Univ, Sch & Hosp Stomatol, Fujian Prov Engn Res Ctr Oral Biomat & Stomatol Ke, Fujian Coll & Univ, Fuzhou, Peoples R China
[3] Fujian Med Univ, Dept Prosthodont, Fuzhou, Peoples R China
[4] Fujian Med Univ, Res Ctr Dent Esthet & Biomech, Fuzhou, Peoples R China
[5] Nagasaki Univ, Grad Sch Biomed Sci, Dept Appl Prosthodont, Nagasaki, Japan
[6] Fujian Med Univ, Sch & Hosp Stomatol, Dept Prosthodont, Yangqiao Zhong Rd 246, Fuzhou, Peoples R China
关键词
Accuracy; Intraoral conditions; Dental implant; Dental impression technique; Intraoral scanner; IN-VIVO PRECISION; 3-DIMENSIONAL ACCURACY; IMPACT; VITRO;
D O I
10.2186/jpr.JPR_D_22_00242
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To compare the trueness and precision of different impression techniques for two-implant-supported fixed dental prostheses between extraoral and intraoral conditions at different locations.Methods: Six volunteers participated in this study. A resin block with two parallel analogs was fabricated as an implant site simulator (ISS). The ISS was bonded to a molded ethylene vinyl acetate sheet to create a reference model. For each participant, four reference models were prepared based on the locations of the ISSs: maxillary posterior/anterior region (MaxP/MaxA) and mandibular posterior/anterior region (ManP/ManA). Five impressions were taken extraorally using the open-tray (conventional implant impression technique, CIT) and intraoral scanning (digital implant impression technique, DIT) techniques. The reference models were positioned in the participants' mouths, and impressions were obtained intraorally using the CIT and DIT. The interanalog distance (d) and angulation (theta) were measured to calculate trueness (Delta d, Delta theta) and precision (dP, theta P). Two-way ANOVA and t tests were performed (alpha=0.05).Results: For the DIT, under intraoral conditions, the Delta d and Delta theta in MaxP and Delta theta in ManP were significantly higher than those under extraoral conditions. For the CIT, under intraoral conditions, the Delta d and Delta theta in ManA and ManP and Delta theta in MaxP were significantly lower than those under extraoral conditions. No significant differences in the dP and theta P of either DIT or CIT were observed between the two conditions.Conclusions: Intraoral conditions affected the trueness of DIT and CIT in different regions but had no influence on precision.
引用
收藏
页码:633 / 640
页数:8
相关论文
共 50 条
  • [31] Effect of Splinted and Nonsplinted Impression Techniques on the Accuracy of Fit of Fixed Implant Prostheses in Edentulous Patients: A Comparative Study
    Papaspyridakos, Panos
    Lal, Kunal
    White, George Shelby
    Weber, Hans-Peter
    Gallucci, German O.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2011, 26 (06) : 1267 - 1272
  • [32] Accuracy of photogrammetric imaging versus conventional impressions for complete arch implant-supported fixed dental prostheses: A comparative clinical study
    Zhang, Yi-Jie
    Qian, Shu-Jiao
    Lai, Hong-Chang
    Shi, Jun-Yu
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 130 (02): : 212 - 218
  • [33] Merging intraoral scans and CBCT: a novel technique for improving the accuracy of 3D digital models for implant-supported complete-arch fixed dental prostheses
    Gomez-Polo, Miguel
    Ballesteros, Juan
    Perales-Padilla, Pedro
    Perales-Pulido, Pedro
    Revilla-Leon, Marta
    Ortega, Rocio
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2021, 24 (02) : 117 - 123
  • [34] A guide for selecting the intraoral scan extension when fabricating tooth- and implant-supported fixed dental prostheses
    Revilla-Leon, Marta
    Gomez-Polo, Miguel
    Kois, John C.
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2024, 36 (01) : 85 - 93
  • [35] Intraoral scanning for implant-supported complete-arch fixed dental prostheses (ISCFDPs): Four clinical reports
    Nagai, Toshiki
    Liu, Weiqing
    Yang, Chao-Chieh
    Polido, Waldemar D.
    Morton, Dean
    Lin, Wei-Shao
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024,
  • [36] In vitro comparison of trueness of 10 intraoral scanners for implant-supported complete-arch fixed dental prostheses
    Bilmenoglu, Caglar
    Cilingir, Altug
    Geckili, Onur
    Bilhan, Hakan
    Bilgin, Tayfun
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (06): : 755 - 760
  • [37] Fracture behavior of all-ceramic, implant-supported, and tooth-implant-supported fixed dental prostheses
    Alkharrat, Abdul Rahman
    Schmitter, Marc
    Rues, Stefan
    Rammelsberg, Peter
    CLINICAL ORAL INVESTIGATIONS, 2018, 22 (04) : 1663 - 1673
  • [38] Accuracy of Digital Dental Implants Impression Taking with Intraoral Scanners Compared with Conventional Impression Techniques: A Systematic Review of In Vitro Studies
    Albanchez-Gonzalez, Maria Isabel
    Brinkmann, Jorge Cortes-Breton
    Pelaez-Rico, Jesus
    Lopez-Suarez, Carlos
    Rodriguez-Alonso, Veronica
    Suarez-Garcia, Maria Jesus
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (04)
  • [39] Fracture behavior of all-ceramic, implant-supported, and tooth–implant-supported fixed dental prostheses
    Abdul Rahman Alkharrat
    Marc Schmitter
    Stefan Rues
    Peter Rammelsberg
    Clinical Oral Investigations, 2018, 22 : 1663 - 1673
  • [40] Short-term complications of implant-supported and combined tooth-implant-supported fixed dental prostheses
    Rammelsberg, Peter
    Schwarz, Stefanie
    Schroeder, Christin
    Bermejo, Justo L.
    Gabbert, Olaf
    CLINICAL ORAL IMPLANTS RESEARCH, 2013, 24 (07) : 758 - 762