Patient skin dose measurement and risk of deterministic effect during fluoroscopy cardiac procedures

被引:1
|
作者
Nana, Ruth Njantang [1 ,2 ]
Inkoom, Stephen [3 ,4 ]
Moyo, Maurice Ndontchueng [1 ,2 ]
Mvoufo, Fokou [1 ,2 ]
Hasford, Francis [3 ,5 ]
Owusu-Manteaw, Philip [4 ]
Motapon, Ousmanou [1 ,6 ]
机构
[1] Univ Douala, Postgrad Sch Fundamental & Appl Sci, Fundamental Phys Lab, POB 24157, Douala, Cameroon
[2] Natl Radiat Protect Agcy NRPA, POB 5331, Akwa, Douala, Cameroon
[3] Univ Ghana, Sch Nucl & Allied Sci, POB AE 1, Accra, Ghana
[4] Ghana Atom Energy Commiss, Radat Protect Inst, POB LG80, Legon, Accra, Ghana
[5] Ghana Atom Energy Commiss, Radiol & Med Sci Res Inst, POB LG80, Legon, Accra, Ghana
[6] Univ Maroua, Fac Sci, POB 814, Maroua, Cameroon
关键词
BACKSCATTER FACTORS;
D O I
10.1093/rpd/ncad206
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study aimed at assessing patient's peak skin doses (PSD) during fluoroscopy cardiac procedures and proposed a look up table to enhance patient's dose management. Perspex phantom and thermoluminescent dosemeters (TLD) were irradiated for different dose levels with X-ray equipment (Philips Azurion 7). It was found that PSD measures were higher than the kerma at the interventional reference point [K (IRP)] reported with factors 1.55, 1.75 and 2.88 for anterior posterior (AP0(o)), left anterior oblique (LAO45(o)) and right anterior oblique (RAO45(o)), respectively. The equations describing the correlation between the PSD measured kerma area product and cumulative air kerma were found with R-square values of 0.98 and 0.99, respectively. The statistical analysis shows a strong linear correlation between PSD and K (IRP) (P-value = 0.05). It was also found that 27% of the patients population considered in this work, received a skin dose higher than the threshold of deterministic effect of 2 Gy and a look up table with the equation of fitness were proposed to be implemented in the facility for K (IRP) higher than 500 mGy.
引用
收藏
页码:2053 / 2060
页数:8
相关论文
共 50 条
  • [1] Patient skin dose in cardiac interventional procedures: Conventional fluoroscopy versus pulsed fluoroscopy
    Chida, Koichi
    Fuda, Kenji
    Saito, Haruo
    Takai, Yoshihiro
    Takahashi, Shoki
    Yamada, Shogo
    Kohzuki, Masahiro
    Zuguchi, Masayuki
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2007, 69 (01) : 115 - 121
  • [2] Patient's skin dose estimation and investigation of factors for dose reduction in fluoroscopy guided procedures
    Nana, Ruth Njantang
    Gyekye, Prince Kwabena
    Inkoom, Stephen
    Hasford, Francis
    Fokou, Mvoufo
    Ndontchueng, Maurice Moyo
    Motapon, Ousmanou
    HEALTH AND TECHNOLOGY, 2024, 14 (03) : 487 - 494
  • [3] Patient’s skin dose estimation and investigation of factors for dose reduction in fluoroscopy guided procedures
    Ruth Njantang Nana
    Prince Kwabena Gyekye
    Stephen Inkoom
    Francis Hasford
    Mvoufo Fokou
    Maurice Moyo Ndontchueng
    Ousmanou Motapon
    Health and Technology, 2024, 14 : 487 - 494
  • [4] Radiation Peak Skin Dose to Risk Stratify Electrophysiological Procedures for Deterministic Skin Damage
    J.R. Paisey
    A.M. Yue
    A. White
    A. Moss
    J.M. Morgan
    P.R. Roberts
    The International Journal of Cardiovascular Imaging, 2004, 20 : 285 - 288
  • [5] Radiation peak skin dose to risk stratify electrophysiological procedures for deterministic skin damage
    Paisey, JR
    Yue, AM
    White, A
    Moss, A
    Morgan, JM
    Roberts, PR
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2004, 20 (04): : 285 - 288
  • [6] Lowering fluoroscopy pulse rates to reduce radiation dose during cardiac procedures
    Crowhurst, James
    Whitby, Mark
    JOURNAL OF MEDICAL RADIATION SCIENCES, 2018, 65 (04): : 247 - 249
  • [7] Patient radiation dose during CT fluoroscopy guided percutaneous interventional procedures
    Daly, BD
    Regits, W
    Pham, CN
    White, DE
    Hartman, EM
    Westerman, BR
    RADIOLOGY, 1999, 213P : 285 - 285
  • [8] Patient Skin Reactions From Interventional Fluoroscopy Procedures
    Balter, Stephen
    Miller, Donald L.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 202 (04) : W335 - W342
  • [9] Direct measurement of a patient's entrance skin dose during pediatric cardiac catheterization
    Sun, Lue
    Mizuno, Yusuke
    Iwamoto, Mari
    Goto, Takahisa
    Koguchi, Yasuhiro
    Miyamoto, Yuka
    Tsuboi, Koji
    Chida, Koichi
    Moritake, Takashi
    JOURNAL OF RADIATION RESEARCH, 2014, 55 (06) : 1122 - 1130
  • [10] Management of patient dose during fluoroscopy
    Archer, BR