Reproducibility of non-contrast enhanced multi breath-hold ultrashort echo time functional lung MRI

被引:0
|
作者
Metz, C. [1 ,3 ,4 ,5 ]
Weng, A. M. [1 ]
Heidenreich, J. F. [1 ]
Slawig, A. [1 ]
Benkert, T. [2 ]
Koestler, H. [1 ]
Veldhoen, S. [1 ,3 ,4 ,5 ]
机构
[1] Univ Hosp Wurzburg, Dept Diagnost & Intervent Radiol, Wurzburg, Germany
[2] Siemens Healthcare GmbH, MR Applicat Predev, Erlangen, Germany
[3] Charite, Augustenburger Pl 1, D-13353 Berlin, Germany
[4] Free Univ Berlin, Augustenburger Pl 1, D-13353 Berlin, Germany
[5] Humboldt Univ, Pediat Radiol, Augustenburger Pl 1, D-13353 Berlin, Germany
关键词
Functional lung MRI; Ultrashort echo time; UTE; Stack-of-spirals; Fractional ventilation; Reproducibility; VENTILATION ASSESSMENT; FOURIER DECOMPOSITION; TIDAL VOLUME; RECONSTRUCTION; PERFUSION; STANDARD;
D O I
10.1016/j.mri.2023.01.020
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the intraindividual reproducibility of functional lung imaging using non-contrast enhanced multi breath-hold 3D-UTE MRI.Methods: Ten healthy volunteers underwent non-contrast enhanced 3D-UTE MRI at three time points for same -day and different-day measurements employing a stack-of-spirals trajectory at 3 T. At each time point, inspi-ratory and expiratory breathing states were acquired for tidal and deep breathing, each within a single breath -hold. For functional image analysis, fractional ventilation (FV) was calculated pixelwise after image registration from the MR signal change. To decouple FV from breathing depth, the individual lung volume was used for volume adjustment (rFV). Reproducibility evaluation was performed in eight lung segments. Statistical analyses included two way mixed intraclass correlation (ICC), sign-test, Friedman-test and modified Bland-Altman analyses.Results: FV from tidal breathing showed an ICC of 0.81, a bias of 1.3% and an interval of confidence (CI) ranging from-67.1 to 69.6%. FV from deep breathing was higher reproducible with an ICC of 0.92 (bias,-0.2%; CI,-34.2 to 33.7%). Following volume adjustment, reproducibility of rFV for tidal breathing improved (ICC, 0,86; bias, 2.0%; CI,-34.3 to 38.3%), whereas it did not bear significant benefits for deep breathing (ICC, 0.89; bias, 2.8%; CI,-24.9 to 30.5%). Reproducibility was independent from the examination day. Conclusion: Non-contrast-enhanced multi breath-hold 3D-UTE MRI allows for highly reproducible ventilation imaging.
引用
收藏
页码:149 / 154
页数:6
相关论文
共 50 条
  • [41] Patency of coronary bypass grafts:: Assessment with breath-hold contrast-enhanced MR angiography -: Value of a non-electrocardiographically triggered technique
    Wintersperger, BJ
    Engelmann, MG
    von Smekal, A
    Knez, A
    Penzkofer, HV
    Höfling, B
    Laub, G
    Reiser, MF
    RADIOLOGY, 1998, 208 (02) : 345 - 351
  • [42] CHILDREN - Functional Lung Imaging using non-contrast-enhanced dynamic MRI
    Lorenz, Judith
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2024, 196 (10): : 1016 - 1016
  • [43] Non-contrast-enhanced 3D MR portography within a breath-hold using compressed sensing acceleration: A prospective noninferiority study
    Ono, Ayako
    Arizono, Shigeki
    Fujimoto, Koji
    Akasaka, Thai
    Yamashita, Rikiya
    Furuta, Akihiro
    Isoda, Hiroyoshi
    Togashi, Kaori
    MAGNETIC RESONANCE IMAGING, 2017, 43 : 42 - 47
  • [44] Comparison of diagnostic performance for pulmonary nodule detection between free-breathing spiral ultrashort echo time and free-breathing radial volumetric interpolated breath-hold examination
    Jiang, Yehai
    Pu, Doudou
    Zhang, Xuyang
    Ren, Zhanli
    Yu, Nan
    BMC MEDICAL IMAGING, 2025, 25 (01):
  • [45] Contrast-enhanced MRI of the menisci of the knee using ultrashort echo time (UTE) pulse sequences: imaging of the red and white zones
    Gatehouse, PD
    He, T
    Puri, BK
    Thomas, RD
    Resnick, D
    Bydder, GM
    BRITISH JOURNAL OF RADIOLOGY, 2004, 77 (920): : 641 - 647
  • [46] Analysis of artefacts and detail resolution of lung MRI with breath-hold T1-weighted gradient-echo and T2-weighted fast spin-echo sequences with respiratory triggering
    Biederer, J
    Reuter, M
    Both, M
    Muhle, C
    Grimm, J
    Graessner, J
    Heller, M
    EUROPEAN RADIOLOGY, 2002, 12 (02) : 378 - 384
  • [47] Analysis of artefacts and detail resolution of lung MRI with breath-hold T1-weighted gradient-echo and T2-weighted fast spin-echo sequences with respiratory triggering
    J. Biederer
    M. Reuter
    M. Both
    C. Muhle
    J. Grimm
    J. Graessner
    M. Heller
    European Radiology, 2002, 12 : 378 - 384
  • [48] Breath-hold contrast-enhanced three-dimensional MR angiography of the abdomen: Time-resolved imaging versus single-phase imaging
    Van Hoe, L
    De Jaegere, T
    Bosmans, H
    Stockx, L
    Vanbeckevoort, D
    Oyen, R
    Fagard, R
    Marchal, G
    RADIOLOGY, 2000, 214 (01) : 149 - 156
  • [49] MR Imaging of the chest using a contrast-enhanced breath-hold modified three-dimensional gradient-echo technique: Comparison with two-dimensional gradient-echo technique and multidetector CT
    Karabulut, N
    Martin, DR
    Yang, M
    Tallaksen, RJ
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (05) : 1225 - 1233
  • [50] Comparative evaluation of TEE, conventional MRI and contrast-enhanced 3D breath-hold MRA in the post-operative follow-up of dissecting aneurysms
    Ernesto Di Cesare
    Aldo Victor Giordano
    Gabriella Cerone
    Francesco De Remigis
    Giuseppe D'Eusanio
    Carlo Masciocchi
    The International Journal of Cardiac Imaging, 2000, 16 : 135 - 147