Indium Kα radiation from a MetalJet X-ray source: comparison of the Eiger2 CdTe and Photon III detectors

被引:5
|
作者
Ruth, Paul Niklas [1 ]
Graw, Nico [1 ]
Ernemann, Tobias [1 ]
Herbst-Irmer, Regine [1 ]
Stalke, Dietmar [1 ]
机构
[1] Georg August Univ Gottingen, Inst Anorgan Chem, Tammannstr 4, D-37077 Gottingen, Lower Saxony, Germany
关键词
In radiation; independent-atom model; multipole model; Hirshfeld atom refinement; MetalJet; detectors; EMPIRICAL CORRECTION; ELECTRON-DENSITY; CONTAMINATION; CARBIDES;
D O I
10.1107/S1600576723007215
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The MetalJet source makes available new K alpha radiation wavelengths for use in X-ray diffraction experiments. The purpose of this paper is to demonstrate the application of indium K alpha radiation in independent-atom model refinement, as well as approaches using aspherical atomic form factors. The results vary greatly depending on the detector employed, as the energy cut-off of the Eiger2 CdTe provides a solution to a unique energy contamination problem of the MetalJet In radiation, which the Photon III detector cannot provide.
引用
收藏
页码:1322 / 1329
页数:8
相关论文
共 50 条
  • [21] Applications with a brighter X-ray source and new detectors from Agilent
    Gal, Z.
    Skarzynski, T.
    White, F.
    Presly, O.
    Jones, A.
    Kucharczyk, D.
    Meyer, M.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2014, 70 : C1734 - C1734
  • [22] Photon-counting energy-resolving CdTe detectors for high-flux x-ray imaging
    Barber, William C.
    Nygard, Einar
    Wessel, Jan C.
    Malakhov, Nail
    Hartsough, Neal E.
    Gandhi, Thulasi
    Wawrzyniak, Gregor
    Iwanczyk, Jan S.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3953 - 3955
  • [23] Measurement of K series of X-ray fluorescence spectra of Ce and Gd by high energy X-ray from synchrotron radiation source
    Harada, Masaaki
    Shoji, Masahiko
    Kawata, Hiroshi
    Sakurai, Kenji
    BUNSEKI KAGAKU, 2006, 55 (06) : 433 - 439
  • [24] LiF detectors application for detection of X-ray radiation from plasma
    Bakshaev, YL
    PLASMA DEVICES AND OPERATIONS, 1999, 7 (02): : 157 - 161
  • [25] SYNCHROTRON RADIATION AS A PHOTON SOURCE FOR PHOTOELECTRON SPECTROMETRY IN THE SOFT X-RAY RANGE.
    Wuilleumier, F.
    Adam, M.Y.
    Dhez, P.
    Sandner, N.
    Mehlhorn, W.
    Schmidt, V.
    Japanese journal of applied physics, 1978, 17 Suppl 17-2 : 44 - 49
  • [26] Experiment for X-ray photon correlation spectroscopy - Coherence of soft X-ray radiation from the undulator of KEK
    Itoh, M
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 1999, 38 : 638 - 641
  • [27] Single photon counting X-ray imaging with Si and CdTe single chip pixel detectors and multichip pixel modules
    Löcker, M
    Fischer, P
    Krimmel, S
    Krüger, H
    Lindner, M
    Nakazawa, K
    Takahashi, T
    Wermes, N
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (04) : 1717 - 1723
  • [28] A new method for the growth of CdTe crystals for RT X-ray photon detectors in the 1-100 keV range
    Lovergine, N
    Mancini, AM
    Cola, A
    Prete, P
    Mazzer, M
    Quaranta, F
    Tapfer, L
    SENSORS AND MICROSYSTEMS, 2000, : 416 - 421
  • [29] Electric Field and Current Transport Mechanisms in Schottky CdTe X-ray Detectors under Perturbing Optical Radiation
    Cola, Adriano
    Farella, Isabella
    SENSORS, 2013, 13 (07): : 9414 - 9434
  • [30] Metrology of a mirror at the Advanced Photon Source: comparison between optical and x-ray measurements
    Assoufid, L
    Lang, J
    Wang, J
    Srajer, G
    ADVANCES IN MIRROR TECHNOLOGY FOR SYNCHROTRON X-RAY AND LASER APPLICATIONS, 1998, 3447 : 109 - 116