Detectability and Volumetric Accuracy of Pulmonary Nodules in Low-Dose Photon-Counting Detector Computed Tomography: An Anthropomorphic Phantom Study

被引:3
|
作者
Hop, Joost F. [1 ]
Walstra, Anna N. H. [1 ]
Pelgrim, Gert-Jan [1 ]
Xie, Xueqian [2 ]
Panneman, Noor A. [1 ]
Schurink, Niels W. [3 ]
Faby, Sebastian [4 ]
van Straten, Marcel [5 ]
de Bock, Geertruida H. [6 ]
Vliegenthart, Rozemarijn [1 ]
Greuter, Marcel J. W. [1 ]
机构
[1] Univ Med Ctr Groningen, Dept Radiol, NL-9713 GZ Groningen, Netherlands
[2] Shanghai Jiao Tong Univ, Shanghai Gen Hosp, Dept Radiol, Sch Med, Shanghai 200080, Peoples R China
[3] Siemens Healthineers Nederland BV, Nl-2595 BN Den Hague, Netherlands
[4] Siemens Healthcare GmbH, Computed Tomog, D-91301 Forchheim, Germany
[5] Erasmus Univ, Med Ctr, Dept Radiol, NL-3015 GD Rotterdam, Netherlands
[6] Univ Med Ctr Groningen, Dept Epidemiol, NL-9713 GZ Groningen, Netherlands
关键词
computed tomography; X-ray; photon-counting detector; low-dose CT; lung cancer; imaging phantom; pulmonary nodules; dose reduction; LUNG-CANCER; CT; AGREEMENT;
D O I
10.3390/diagnostics13223448
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this phantom study was to assess the detectability and volumetric accuracy of pulmonary nodules on photon-counting detector CT (PCD-CT) at different low-dose levels compared to conventional energy-integrating detector CT (EID-CT). In-house fabricated artificial nodules of different shapes (spherical, lobulated, spiculated), sizes (2.5-10 mm and 5-1222 mm(3)), and densities (-330 HU and 100 HU) were randomly inserted into an anthropomorphic thorax phantom. The phantom was scanned with a low-dose chest protocol with PCD-CT and EID-CT, in which the dose with PCD-CT was lowered from 100% to 10% with respect to the EID-CT reference dose. Two blinded observers independently assessed the CT examinations of the nodules. A third observer measured the nodule volumes using commercial software. The influence of the scanner type, dose, observer, physical nodule volume, shape, and density on the detectability and volumetric accuracy was assessed by a multivariable regression analysis. In 120 CT examinations, 642 nodules were present. Observer 1 and 2 detected 367 (57%) and 289 nodules (45%), respectively. With PCD-CT and EID-CT, the nodule detectability was similar. The physical nodule volumes were underestimated by 20% (range 8-52%) with PCD-CT and 24% (range 9-52%) with EID-CT. With PCD-CT, no significant decrease in the detectability and volumetric accuracy was found at dose reductions down to 10% of the reference dose (p > 0.05). The detectability and volumetric accuracy were significantly influenced by the observer, nodule volume, and a spiculated nodule shape (p < 0.05), but not by dose, CT scanner type, and nodule density (p > 0.05). Low-dose PCD-CT demonstrates potential to detect and assess the volumes of pulmonary nodules, even with a radiation dose reduction of up to 90%.
引用
收藏
页数:13
相关论文
共 50 条
  • [11] Subsolid Pulmonary Nodules in Low-Dose Computed Tomography
    Hekmat, K.
    Bruns, C. J.
    CHIRURG, 2018, 89 (12): : 1008 - 1008
  • [12] Sensitivity and accuracy of volumetry of pulmonary nodules on low-dose 16- and 64-row multi-detector CT: an anthropomorphic phantom study
    Xueqian Xie
    Yingru Zhao
    Roland A. Snijder
    Peter M. A. van Ooijen
    Pim A. de Jong
    Matthijs Oudkerk
    Geertruida H. de Bock
    Rozemarijn Vliegenthart
    Marcel J. W. Greuter
    European Radiology, 2013, 23 : 139 - 147
  • [13] Sensitivity and accuracy of volumetry of pulmonary nodules on low-dose 16-and 64-row multi-detector CT: an anthropomorphic phantom study
    Xie, Xueqian
    Zhao, Yingru
    Snijder, Roland A.
    van Ooijen, Peter M. A.
    de Jong, Pim A.
    Oudkerk, Matthijs
    de Bock, Geertruida H.
    Vliegenthart, Rozemarijn
    Greuter, Marcel J. W.
    EUROPEAN RADIOLOGY, 2013, 23 (01) : 139 - 147
  • [14] Photon-counting computed tomography of coronary and peripheral artery stents: a phantom study
    Thomas Stein
    Jana Taron
    Niklas Verloh
    Michael Doppler
    Alexander Rau
    Muhammad Taha Hagar
    Sebastian Faby
    Dimos Baltas
    Dirk Westermann
    Isabelle Ayx
    Stefan O. Schönberg
    Konstantin Nikolaou
    Christopher L. Schlett
    Fabian Bamberg
    Jakob Weiss
    Scientific Reports, 13
  • [15] Photon-counting computed tomography of coronary and peripheral artery stents: a phantom study
    Stein, Thomas
    Taron, Jana
    Verloh, Niklas
    Doppler, Michael
    Rau, Alexander
    Hagar, Muhammad Taha
    Faby, Sebastian
    Baltas, Dimos
    Westermann, Dirk
    Ayx, Isabelle
    Schoenberg, Stefan O.
    Nikolaou, Konstantin
    Schlett, Christopher L.
    Bamberg, Fabian
    Weiss, Jakob
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [16] Accuracy of Pulmonary Nodule Volumetry at Different Exposure Parameters in Low-Dose Computed Tomography: A Phantom Study
    Liu, Jieke
    Qing, Haomiao
    Luo, Hongbing
    He, Changjiu
    Wang, Chunhua
    Ren, Jing
    Zhou, Peng
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2019, 43 (06) : 926 - 930
  • [17] Virtual Noncontrast Imaging of the Liver Using Photon-Counting Detector Computed Tomography A Systematic Phantom and Patient Study
    Sartoretti, Thomas
    Mergen, Victor
    Higashigaito, Kai
    Eberhard, Matthias
    Alkadhi, Hatem
    Euler, Andre
    INVESTIGATIVE RADIOLOGY, 2022, 57 (07) : 488 - 493
  • [18] Photon-Counting Computed Tomography for the Diagnosis of Pulmonary Embolism
    Kumar, Pratik
    JOURNAL OF MEDICAL PHYSICS, 2023, 48 (01) : 100 - 101
  • [19] Microstructural Imaging of Bone by Photon-Counting Detector Computed Tomography
    Burghardt, Andrew
    Korajac, Aida
    Strassl, Andreas
    Sadoughi, Saghi
    Kazakia, Galateia
    Patsch, Janina
    JOURNAL OF BONE AND MINERAL RESEARCH, 2023, 38 : 342 - 343
  • [20] Image quality of opportunistic breast examinations in photon-counting computed tomography: A phantom study
    Sawall, S.
    Baader, E.
    Wolf, J.
    Maier, J.
    Schlemmer, H. -P.
    Schoenberg, S. O.
    Sechopoulos, I.
    Kachelriess, M.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2024, 122