Thermal Calibration of Triaxial Accelerometer for Tilt Measurement

被引:7
|
作者
Yuan, Bo [1 ]
Tang, Zhifeng [2 ]
Zhang, Pengfei [2 ]
Lv, Fuzai [3 ]
机构
[1] Zhejiang Univ, Polytech Inst, Hangzhou 310027, Peoples R China
[2] Zhejiang Univ, Coll Biomed Engn & Instrument Sci, Hangzhou 310027, Peoples R China
[3] Zhejiang Univ, Sch Mech Engn, State Key Lab Fluid Power & Mechatron Syst, 38 Zheda Rd, Hangzhou 310027, Peoples R China
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
MEMS; triaxial accelerometer; error analysis; thermal drift; calibration; temperature compensation; tilt measurement; OPTIMIZATION; ACCURACY;
D O I
10.3390/s23042105
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The application of MEMS accelerometers used to measure inclination is constrained by their temperature dependence, and each accelerometer needs to be calibrated individually to increase stability and accuracy. This paper presents a calibration and thermal compensation method for triaxial accelerometers that aims to minimize cost and processing time while maintaining high accuracy. First, the number of positions to perform the calibration procedure is optimized based on the Levenberg-Marquardt algorithm, and then, based on this optimized calibration number, thermal compensation is performed based on the least squares method, which is necessary for environments with large temperature variations, since calibration parameters change at different temperatures. The calibration procedures and algorithms were experimentally validated on marketed accelerometers. Based on the optimized calibration method, the calibrated results achieved nearly 100 times improvement. Thermal drift calibration experiments on the triaxial accelerometer show that the thermal compensation scheme in this paper can effectively reduce drift in the temperature range of -40 degrees C to 60 degrees C. The temperature drifts of x- and y-axes are reduced from -13.2 and 11.8 mg to -0.9 and -1.1 mg, respectively. The z-axis temperature drift is reduced from -17.9 to 1.8 mg. We have conducted various experiments on the proposed calibration method and demonstrated its capacity to calibrate the sensor frame error model (SFEM) parameters. This research proposes a new low-cost and efficient strategy for increasing the practical applicability of triaxial accelerometers.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Calibration of triaxial MEMS vector field measurement system
    Zhang Xiaoming
    Chen Guobin
    Li Jie
    Liu Jun
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2014, 8 (06) : 601 - 609
  • [32] Online auto-calibration of triaxial accelerometer with time-variant model structures
    Ye, L.
    Argha, A.
    Celler, B. G.
    Nguyen, H. T.
    Su, S. W.
    SENSORS AND ACTUATORS A-PHYSICAL, 2017, 266 : 294 - 307
  • [33] In-Field Calibration of Triaxial Accelerometer Based on Beetle Swarm Antenna Search Algorithm
    Wang, Pengfei
    Gao, Yanbin
    Wu, Menghao
    Zhang, Fan
    Li, Guangchun
    SENSORS, 2020, 20 (03)
  • [34] Accelerometer Triad Calibration for Pole Tilt Compensation Using Variance Based Sensitivity Analysis
    Thalmann, Tomas
    Zechner, Manuel
    Neuner, Hans
    SENSORS, 2020, 20 (05)
  • [35] Tilt meter as a tilt-independent accelerometer
    Giazotto, A.
    PHYSICS LETTERS A, 2012, 376 (05) : 667 - 670
  • [36] TRIAXIAL ACCELEROMETER SYSTEM OF AE
    CHAMPION, KS
    MARCOS, FA
    TRANSACTIONS-AMERICAN GEOPHYSICAL UNION, 1973, 54 (04): : 208 - 208
  • [37] Surface micromachined triaxial accelerometer
    Reichenbach, R
    Schubert, D
    Gerlach, G
    TECHNISCHES MESSEN, 2003, 70 (05): : 225 - 232
  • [38] Triaxial Bragg grating accelerometer
    Morikawa, SRK
    Ribeiro, AS
    Regazzi, RD
    Valente, LCG
    Braga, AMB
    OFS 2002: 15TH OPTICAL FIBER SENSORS CONFERENCE TECHNICAL DIGEST, 2002, : 95 - 98
  • [39] Design of a triaxial piezoelectric accelerometer
    Huang, PS
    Ren, TL
    Lou, QW
    Liu, JS
    Liu, LT
    Li, ZJ
    INTEGRATED FERROELECTRICS, 2003, 56 : 1115 - 1122
  • [40] Measurement of Motion Activity during Ambulatory Using Pulse Oximeter and Triaxial Accelerometer
    Lee, Young-Dong
    Jung, Sang-Joong
    Seo, Yong-Su
    Chung, Wan-Young
    THIRD 2008 INTERNATIONAL CONFERENCE ON CONVERGENCE AND HYBRID INFORMATION TECHNOLOGY, VOL 1, PROCEEDINGS, 2008, : 436 - +