Thermal Calibration of Triaxial Accelerometer for Tilt Measurement

被引:7
|
作者
Yuan, Bo [1 ]
Tang, Zhifeng [2 ]
Zhang, Pengfei [2 ]
Lv, Fuzai [3 ]
机构
[1] Zhejiang Univ, Polytech Inst, Hangzhou 310027, Peoples R China
[2] Zhejiang Univ, Coll Biomed Engn & Instrument Sci, Hangzhou 310027, Peoples R China
[3] Zhejiang Univ, Sch Mech Engn, State Key Lab Fluid Power & Mechatron Syst, 38 Zheda Rd, Hangzhou 310027, Peoples R China
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
MEMS; triaxial accelerometer; error analysis; thermal drift; calibration; temperature compensation; tilt measurement; OPTIMIZATION; ACCURACY;
D O I
10.3390/s23042105
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The application of MEMS accelerometers used to measure inclination is constrained by their temperature dependence, and each accelerometer needs to be calibrated individually to increase stability and accuracy. This paper presents a calibration and thermal compensation method for triaxial accelerometers that aims to minimize cost and processing time while maintaining high accuracy. First, the number of positions to perform the calibration procedure is optimized based on the Levenberg-Marquardt algorithm, and then, based on this optimized calibration number, thermal compensation is performed based on the least squares method, which is necessary for environments with large temperature variations, since calibration parameters change at different temperatures. The calibration procedures and algorithms were experimentally validated on marketed accelerometers. Based on the optimized calibration method, the calibrated results achieved nearly 100 times improvement. Thermal drift calibration experiments on the triaxial accelerometer show that the thermal compensation scheme in this paper can effectively reduce drift in the temperature range of -40 degrees C to 60 degrees C. The temperature drifts of x- and y-axes are reduced from -13.2 and 11.8 mg to -0.9 and -1.1 mg, respectively. The z-axis temperature drift is reduced from -17.9 to 1.8 mg. We have conducted various experiments on the proposed calibration method and demonstrated its capacity to calibrate the sensor frame error model (SFEM) parameters. This research proposes a new low-cost and efficient strategy for increasing the practical applicability of triaxial accelerometers.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Design and measurement of a piezoresistive triaxial accelerometer based on MEMS technology
    Du Chunhui
    He Changde
    Yu Jiaqi
    Ge Xiaoyang
    Zhang Yongping
    Zhang Wendong
    JOURNAL OF SEMICONDUCTORS, 2012, 33 (10)
  • [22] Design and measurement of a piezoresistive triaxial accelerometer based on MEMS technology
    杜春晖
    何常德
    于佳琪
    葛晓洋
    张永平
    张文栋
    半导体学报, 2012, 33 (10) : 48 - 52
  • [23] The displacement measurement of a shaker in an accelerometer calibration system
    Peng, GS
    Wu, CM
    Huang, YJ
    SECOND INTERNATIONAL CONFERENCE ON VIBRATION MEASUREMENTS BY LASER TECHNIQUES: ADVANCES AND APPLICATIONS, 1996, 2868 : 285 - 289
  • [24] Maximum Likelihood Approach for Low-cost MEMS Triaxial Accelerometer Calibration
    Lu, Xin
    Liu, Zhong
    He, Jingbo
    2016 8TH INTERNATIONAL CONFERENCE ON INTELLIGENT HUMAN-MACHINE SYSTEMS AND CYBERNETICS (IHMSC), VOL. 1, 2016, : 179 - 182
  • [25] Development of a tilt measurement unit using microelectromechanical system accelerometer
    Miskam, A.
    Korakkottil, S.
    Zaidi, M.
    Sidek, O.
    Journal of Applied Sciences, 2009, 9 (13) : 2451 - 2456
  • [26] TRIAXIAL ACCELEROMETER SYSTEM
    WESTLUND, CD
    SMITH, RL
    INSTRUMENTS & CONTROL SYSTEMS, 1972, 45 (09): : 80 - &
  • [27] TRIAXIAL BRIDGE ACCELEROMETER
    WESTLUND, CD
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1971, 42 (05): : 698 - &
  • [28] ON THE DESIGN OF A TRIAXIAL ACCELEROMETER
    LOTTERS, JC
    OLTHUIS, W
    VELTINK, PH
    BERGVELD, P
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 1995, 5 (02) : 128 - 131
  • [29] A piezoelectric triaxial accelerometer
    Scheeper, P
    Gullov, JO
    Kofoed, LM
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 1996, 6 (01) : 131 - 133
  • [30] In Vivo Measurement of Humeral Elevation Angles and Exposure Using a Triaxial Accelerometer
    Amasay, Tal
    Latteri, Michael
    Karduna, Andrew R.
    HUMAN FACTORS, 2010, 52 (06) : 616 - 626