Diagnostic Accuracy of Dual-Energy CT Material Decomposition Technique for Assessing Bone Status Compared with Quantitative Computed Tomography

被引:7
|
作者
Wang, Xu [1 ]
Li, Beibei [1 ]
Tong, Xiaoyu [1 ]
Fan, Yong [1 ]
Wang, Shigeng [1 ]
Liu, Yijun [1 ]
Fang, Xin [1 ]
Liu, Lei [1 ]
机构
[1] Dalian Med Univ, Dept Radiol, Affiliated Hosp 1, Dalian 116014, Peoples R China
关键词
bone density; osteoporosis; quantitative computed tomography (QCT); dual-energy computed tomography (DECT); material decomposition; MINERAL DENSITY; CLINICAL-USE; OSTEOPOROSIS; DXA;
D O I
10.3390/diagnostics13101751
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: The purpose of this study was to evaluate the diagnostic accuracy when using various base material pairs (BMPs) in dual-energy computed tomography (DECT), and to establish corresponding diagnostic standards for assessing bone status through comparison with quantitative computed tomography (QCT). Methods: This prospective study enrolled a total of 469 patients who underwent both non-enhanced chest CT scans under conventional kVp and abdominal DECT. The bone densities of hydroxyapatite (water), hydroxyapatite (fat), hydroxyapatite (blood), calcium (water), and calcium (fat) (D-HAP (water), D-HAP (fat), D-HAP (blood), D-Ca (water), and D-Ca (fat)) in the trabecular bone of vertebral bodies (T11-L1) were measured, along with bone mineral density (BMD) via QCT. Intraclass correlation coefficient (ICC) analysis was used to assess the agreement of the measurements. Spearman's correlation test was performed to analyze the relationship between the DECT- and QCT-derived BMD. Receiver operator characteristic (ROC) curves were generated to determine the optimal diagnostic thresholds of various BMPs for diagnosing osteopenia and osteoporosis. Results: A total of 1371 vertebral bodies were measured, and QCT identified 393 with osteoporosis and 442 with osteopenia. Strong correlations were observed between D-HAP (water), D-HAP (fat), D-HAP (blood), D-Ca (water), and D-Ca (fat) and the QCT-derived BMD. D-HAP (water) showed the best predictive capability for osteopenia and osteoporosis. The area under the ROC curve, sensitivity, and specificity for identifying osteopenia were 0.956, 86.88%, and 88.91% with D-HAP (water) =107.4 mg/cm(3), respectively. The corresponding values for identifying osteoporosis were 0.999, 99.24%, and 99.53% with D-HAP (water)= 89.62 mg/cm(3), respectively. Conclusions: Bone density measurement using various BMPs in DECT enables the quantification of vertebral BMD and the diagnosis of osteoporosis, with D-HAP (water) having the highest diagnostic accuracy.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Material decomposition using dual-energy CT with unsupervised learning
    Chang, Hui-Yu
    Liu, Chi-Kuang
    Huang, Hsuan-Ming
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2023, 46 (04) : 1607 - 1617
  • [42] A comparison of material decomposition techniques for dual-energy CT colonography
    Nasirudin, Radin A.
    Tachibana, Rie
    Naeppi, Janne J.
    Mei, Kai
    Kopp, Felix K.
    Rummeny, Ernst J.
    Yoshida, Hiroyuki
    Noel, Peter B.
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [43] Material decomposition using dual-energy CT with unsupervised learning
    Hui-Yu Chang
    Chi-Kuang Liu
    Hsuan-Ming Huang
    Physical and Engineering Sciences in Medicine, 2023, 46 : 1607 - 1617
  • [44] Dual-Energy CT Material Decomposition in Pediatric Thoracic Oncology
    Siegel, Marilyn J.
    Bhalla, Sanjeev
    Cullinane, Mike
    RADIOLOGY-IMAGING CANCER, 2021, 3 (01):
  • [45] Iterative Reconstruction for Quantitative Tissue Decomposition in Dual-Energy CT
    Magnusson, Maria
    Malusek, Alexandr
    Muhammad, Arif
    Carlsson, Gudrun Alm
    IMAGE ANALYSIS: 17TH SCANDINAVIAN CONFERENCE, SCIA 2011, 2011, 6688 : 479 - 488
  • [46] Diagnostic Imaging Performance of Dual-Energy Computed Tomography Compared with Conventional Computed Tomography and Magnetic Resonance Imaging for Uterine Cervical Cancer
    Shibuki, Saki
    Saida, Tsukasa
    Mori, Kensaku
    Ishiguro, Toshitaka
    Amano, Taishi
    Yoshida, Miki
    Miyata, Mariko
    Satoh, Toyomi
    Nakajima, Takahito
    INDIAN JOURNAL OF RADIOLOGY AND IMAGING, 2024, 34 (04): : 661 - 669
  • [47] Calibration-Free Material Decomposition for Dual-Energy CT
    Zhao, W.
    Xing, L.
    Zhang, Q.
    Xiong, G.
    Min, J.
    MEDICAL PHYSICS, 2016, 43 (06) : 3396 - 3396
  • [48] EVALUATION OF BONE MINERAL STATUS WITH DUAL-ENERGY X-RAY ABSORPTIOMETRY AND QUANTITATIVE COMPUTED TOMOGRAPHY IN CHRONIC RENAL DISEASE
    Alan, Aydan Mutis
    Sezer, Zehra
    Dincer, Mevlut Tamer
    Oz, Ahmet
    Karaca, Cebrail
    Alagoz, Selma
    Guzel, Elif
    Gonen, Mustafa Sait
    Seyahi, Nurhan
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2023, 38 : I634 - I635
  • [49] Penalized-likelihood sinogram decomposition for dual-energy computed tomography
    La Riviere, Patrick J.
    Vargas, Phillip
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4432 - 4435
  • [50] Dual-energy material decomposition for cone-beam computed tomography in image-guided radiotherapy
    Skaarup, Mikkel
    Edmund, Jens M.
    Dorn, Sabrina
    Kachelriess, Marc
    Vogeliu, Ivan R.
    ACTA ONCOLOGICA, 2019, 58 (10) : 1483 - 1488