Diagnostic Accuracy of Dual-Energy CT Material Decomposition Technique for Assessing Bone Status Compared with Quantitative Computed Tomography

被引:7
|
作者
Wang, Xu [1 ]
Li, Beibei [1 ]
Tong, Xiaoyu [1 ]
Fan, Yong [1 ]
Wang, Shigeng [1 ]
Liu, Yijun [1 ]
Fang, Xin [1 ]
Liu, Lei [1 ]
机构
[1] Dalian Med Univ, Dept Radiol, Affiliated Hosp 1, Dalian 116014, Peoples R China
关键词
bone density; osteoporosis; quantitative computed tomography (QCT); dual-energy computed tomography (DECT); material decomposition; MINERAL DENSITY; CLINICAL-USE; OSTEOPOROSIS; DXA;
D O I
10.3390/diagnostics13101751
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: The purpose of this study was to evaluate the diagnostic accuracy when using various base material pairs (BMPs) in dual-energy computed tomography (DECT), and to establish corresponding diagnostic standards for assessing bone status through comparison with quantitative computed tomography (QCT). Methods: This prospective study enrolled a total of 469 patients who underwent both non-enhanced chest CT scans under conventional kVp and abdominal DECT. The bone densities of hydroxyapatite (water), hydroxyapatite (fat), hydroxyapatite (blood), calcium (water), and calcium (fat) (D-HAP (water), D-HAP (fat), D-HAP (blood), D-Ca (water), and D-Ca (fat)) in the trabecular bone of vertebral bodies (T11-L1) were measured, along with bone mineral density (BMD) via QCT. Intraclass correlation coefficient (ICC) analysis was used to assess the agreement of the measurements. Spearman's correlation test was performed to analyze the relationship between the DECT- and QCT-derived BMD. Receiver operator characteristic (ROC) curves were generated to determine the optimal diagnostic thresholds of various BMPs for diagnosing osteopenia and osteoporosis. Results: A total of 1371 vertebral bodies were measured, and QCT identified 393 with osteoporosis and 442 with osteopenia. Strong correlations were observed between D-HAP (water), D-HAP (fat), D-HAP (blood), D-Ca (water), and D-Ca (fat) and the QCT-derived BMD. D-HAP (water) showed the best predictive capability for osteopenia and osteoporosis. The area under the ROC curve, sensitivity, and specificity for identifying osteopenia were 0.956, 86.88%, and 88.91% with D-HAP (water) =107.4 mg/cm(3), respectively. The corresponding values for identifying osteoporosis were 0.999, 99.24%, and 99.53% with D-HAP (water)= 89.62 mg/cm(3), respectively. Conclusions: Bone density measurement using various BMPs in DECT enables the quantification of vertebral BMD and the diagnosis of osteoporosis, with D-HAP (water) having the highest diagnostic accuracy.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Diagnostic accuracy of dual-energy computed tomography in bone marrow edema with vertebral compression fractures: A meta-analysis
    Yang, Pei
    Wu, Guangyao
    Chang, Xiaodan
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 99 : 124 - 129
  • [22] Spectral computed tomography for quantitative decomposition of vulnerable plaques using a dual-energy technique: a Monte Carlo simulation study
    Jo, B. D.
    Park, S. -J.
    Kim, H. M.
    Kim, D. H.
    Kim, H. -J.
    JOURNAL OF INSTRUMENTATION, 2016, 11
  • [23] Dual-energy computed tomography compared with ultrasound in the diagnosis of gout
    Gruber, Michael
    Bodner, Gerd
    Rath, Eva
    Supp, Gabriela
    Weber, Michael
    Schueller-Weidekamm, Claudia
    RHEUMATOLOGY, 2014, 53 (01) : 173 - 179
  • [24] Noise Suppression in Material Decomposition for Dual-Energy CT
    Dong, X.
    Petrongolo, M.
    Wang, T.
    Zhu, L.
    MEDICAL PHYSICS, 2014, 41 (06) : 541 - 541
  • [25] A Hybrid Projection Decomposition Algorithm for Dual-Energy Computed Tomography
    Li, Lei
    Wang, Linyuan
    Xi, Xiaoqi
    Yan, Bin
    Sun, Yanmin
    2016 12TH INTERNATIONAL CONFERENCE ON NATURAL COMPUTATION, FUZZY SYSTEMS AND KNOWLEDGE DISCOVERY (ICNC-FSKD), 2016, : 1352 - 1356
  • [26] Performance evaluation of quantitative material decomposition in slow kVp switching dual-energy CT
    Ma, Chenchen
    Su, Ting
    Zhu, Jiongtao
    Zhang, Xin
    Zheng, Hairong
    Liang, Dong
    Wang, Na
    Zhang, Yunxin
    Ge, Yongshuai
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2024, 32 (01) : 69 - 85
  • [27] Diagnostic accuracy of dual-energy computed tomography angiography in the differentiation of benign and malignant pelvic masses
    Ren, Zhen
    Jiang, Bo
    Wu, Xiong
    Zhang, Zhibang
    Chen, Hongliang
    Cai, Haiyi
    Fu, Chun
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 150
  • [28] Accuracy and applicability of dual-energy computed tomography in quantifying vertebral bone marrow adipose tissue compared with magnetic resonance imaging
    Liu, Zhenghua
    Huang, Dageng
    Zhang, Yuting
    Chang, Rong
    Zhang, Xiaoyue
    Jiang, Yonghong
    Ma, Xiaowen
    INSIGHTS INTO IMAGING, 2022, 13 (01)
  • [29] Accuracy and applicability of dual-energy computed tomography in quantifying vertebral bone marrow adipose tissue compared with magnetic resonance imaging
    Zhenghua Liu
    Dageng Huang
    Yuting Zhang
    Rong Chang
    Xiaoyue Zhang
    Yonghong Jiang
    Xiaowen Ma
    Insights into Imaging, 13
  • [30] Improvement with the Multi-material Decomposition Framework in Dual-energy Computed Tomography: A Phantom Study
    Lee, Haenghwa
    Kim, Hee-Joung
    Lee, Donghoon
    Kim, Dohyeon
    Choi, Seungyeon
    Lee, Minjae
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2020, 77 (06) : 515 - 523