Diagnostic Accuracy of Dual-Energy CT Material Decomposition Technique for Assessing Bone Status Compared with Quantitative Computed Tomography

被引:7
|
作者
Wang, Xu [1 ]
Li, Beibei [1 ]
Tong, Xiaoyu [1 ]
Fan, Yong [1 ]
Wang, Shigeng [1 ]
Liu, Yijun [1 ]
Fang, Xin [1 ]
Liu, Lei [1 ]
机构
[1] Dalian Med Univ, Dept Radiol, Affiliated Hosp 1, Dalian 116014, Peoples R China
关键词
bone density; osteoporosis; quantitative computed tomography (QCT); dual-energy computed tomography (DECT); material decomposition; MINERAL DENSITY; CLINICAL-USE; OSTEOPOROSIS; DXA;
D O I
10.3390/diagnostics13101751
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: The purpose of this study was to evaluate the diagnostic accuracy when using various base material pairs (BMPs) in dual-energy computed tomography (DECT), and to establish corresponding diagnostic standards for assessing bone status through comparison with quantitative computed tomography (QCT). Methods: This prospective study enrolled a total of 469 patients who underwent both non-enhanced chest CT scans under conventional kVp and abdominal DECT. The bone densities of hydroxyapatite (water), hydroxyapatite (fat), hydroxyapatite (blood), calcium (water), and calcium (fat) (D-HAP (water), D-HAP (fat), D-HAP (blood), D-Ca (water), and D-Ca (fat)) in the trabecular bone of vertebral bodies (T11-L1) were measured, along with bone mineral density (BMD) via QCT. Intraclass correlation coefficient (ICC) analysis was used to assess the agreement of the measurements. Spearman's correlation test was performed to analyze the relationship between the DECT- and QCT-derived BMD. Receiver operator characteristic (ROC) curves were generated to determine the optimal diagnostic thresholds of various BMPs for diagnosing osteopenia and osteoporosis. Results: A total of 1371 vertebral bodies were measured, and QCT identified 393 with osteoporosis and 442 with osteopenia. Strong correlations were observed between D-HAP (water), D-HAP (fat), D-HAP (blood), D-Ca (water), and D-Ca (fat) and the QCT-derived BMD. D-HAP (water) showed the best predictive capability for osteopenia and osteoporosis. The area under the ROC curve, sensitivity, and specificity for identifying osteopenia were 0.956, 86.88%, and 88.91% with D-HAP (water) =107.4 mg/cm(3), respectively. The corresponding values for identifying osteoporosis were 0.999, 99.24%, and 99.53% with D-HAP (water)= 89.62 mg/cm(3), respectively. Conclusions: Bone density measurement using various BMPs in DECT enables the quantification of vertebral BMD and the diagnosis of osteoporosis, with D-HAP (water) having the highest diagnostic accuracy.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Assessing the Sensitivity of Dual-Energy Computed Tomography 3-Material Decomposition for the Detection of Gout
    Tse, Justin J.
    Kondro, Douglas A.
    Kuczynski, Michael T.
    Pauchard, Yves
    Veljkovic, Andrea
    Holdsworth, David W.
    Frasson, Viviane
    Manske, Sarah L.
    MacMullan, Paul
    Salat, Peter
    INVESTIGATIVE RADIOLOGY, 2022, 57 (09) : 613 - 619
  • [2] A Novel Methodology for Assessing Material Differentiation in Dual-Energy Computed Tomography
    Schaeffer, C.
    Leon, S.
    Arreola, M.
    MEDICAL PHYSICS, 2022, 49 (06) : E608 - E609
  • [3] Mineral quantitative characterization method based on basis material decomposition model by dual-energy computed tomography
    Zhi, Weijuan
    Zou, Jing
    Zhao, Jintao
    Xia, Xiaoqin
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2023, 31 (02) : 373 - 391
  • [4] ACCURACY OF VERTEBRAL MINERAL DETERMINATION BY DUAL-ENERGY QUANTITATIVE COMPUTED-TOMOGRAPHY
    REINBOLD, WD
    ADLER, CP
    KALENDER, WA
    LENTE, R
    SKELETAL RADIOLOGY, 1991, 20 (01) : 25 - 29
  • [5] Opportunistic screening for osteoporosis using enhanced images based on dual-energy computed tomography material decomposition: a comparison with quantitative computed tomography
    Tong, Xiaoyu
    Fang, Xin
    Wang, Shigeng
    Fan, Yong
    Wei, Wei
    Xiao, Qingzhu
    Chen, Anliang
    Liu, Yijun
    Liu, Lei
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (01) : 352 - 364
  • [6] Impact of Rod Arrangements On Deriving CT to Material Calibration Curve with Dual-Energy Computed Tomography Technique
    Wu, P.
    Chao, T.
    Tsai, Y.
    Wu, T.
    Hsu, W.
    Chiang, Y.
    Lee, C.
    MEDICAL PHYSICS, 2020, 47 (06) : E793 - E793
  • [7] Dual-energy computed tomography material decomposition improves prediction accuracy of hematoma expansion in traumatic intracranial hemorrhage
    Lee, Jungbin
    Park, Sung-Tae
    Hwang, Sun-Chul
    Kim, Jung Youn
    Lee, A. Leum
    Chang, Kee-Hyun
    PLOS ONE, 2023, 18 (07):
  • [8] Dual-Energy Computed Tomography Virtual Noncalcium Technique in Diagnosing Osteoporosis: Correlation With Quantitative Computed Tomography
    Liu, Zhenghua
    Zhang, Yuting
    Liu, Zhou
    Kong, Jiangtao
    Huang, Dageng
    Zhang, Xiaoyue
    Jiang, Yonghong
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2021, 45 (03) : 452 - 457
  • [9] Quantitative material analysis by dual-energy computed tomography for industrial NDT applications
    Nachtrab, F.
    Weis, S.
    Kessling, P.
    Sukowski, F.
    Hassler, U.
    Fuchs, T.
    Uhlmann, N.
    Hanke, R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 633 : S159 - S162
  • [10] Dual-energy CT of the bone marrow in multiple myeloma: diagnostic accuracy for quantitative differentiation of infiltration patterns
    Kosmala, Aleksander
    Weng, Andreas Max
    Krauss, Bernhard
    Knop, Stefan
    Bley, Thorsten Alexander
    Petritsch, Bernhard
    EUROPEAN RADIOLOGY, 2018, 28 (12) : 5083 - 5090