A single-lead ECG based cardiotoxicity detection in patients on polychemotherapy

被引:1
|
作者
Mesitskaya, Dinara F. [2 ]
Fashafsha, Zaki Z. A. [1 ,4 ]
Poltavskaya, Maria G. [2 ]
Andreev, Denis A. [2 ]
Levshina, Anna R. [2 ]
Sultygova, Elizaveta A. [1 ]
Gognieva, Daria [1 ,2 ]
Chomakhidze, Petr [1 ,2 ]
Kuznetsova, Natalia [1 ]
Suvorov, Alexander [1 ]
Marina, Sekacheva [1 ,3 ]
Poddubskaya, Elena [2 ]
Novikova, Alena [2 ]
Bykova, Aleksandra [2 ]
Kopylov, Philipp [1 ,2 ]
机构
[1] Sechenov First Moscow State Med Univ, World Class Res Ctr Digital Biodesign & Personaliz, Moscow, Russia
[2] IM Sechenov First Moscow State Med Univ, Sechenov Univ, Dept Cardiol Funct & Ultrasound Diagnost NV Sklifo, Moscow, Russia
[3] IM Sechenov First Moscow State Med Univ, Inst Personalized Oncol, Ctr Digital Biodesign & Personalized Healthcare, Moscow, Russia
[4] St Bolshaya Pirogovskaya 6,Bldg 1, Moscow 119435, Russia
来源
IJC HEART & VASCULATURE | 2024年 / 50卷
关键词
Single-lead electrocardiogram; Chemotherapy; Cardiotoxicity; Left ventricular diastolic dysfunction; Atrial fibrillation; QTc prolongation;
D O I
10.1016/j.ijcha.2024.101336
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Anti -cancer treatment can be fraught with cardiovascular complications, which is the most common cause of death among oncological survivors. Without appropriate cardiomonitoring during anti -cancer treatment, it becomes challenging to detect early signs of cardiovascular complications. In order to achieve higher survival rates, it is necessary to monitor oncological patients outpatiently after anti -cancer treatment administration. In this regard, we aim to evaluate the efficacy of single -lead ECG remote monitoring to detect cardiotoxicity in cancer patients with minimal cardiovascular diseases after the first cycle of polychemotherapy. Materials and methods: The study included patients 162 patients over 18 years old with first diagnosed different types of solid tumors, planed for adjuvant (within 8 weeks after surgery) or neoadjuvant polychemotherapy. All patients were monitored, outpatiently, during 14-21 days (depending on the regimen of polychemotherapy) after polychemotherapy administration using single -lead ECG. Results: QTc > 500 mc prolongation was detected in 8 patients (6.6 %), first -diagnosed arial fibrillation was detected in 11 patients (9 %) in period after chemotherapy administration. Moreover, left ventricular diastolic dysfunction using single -lead ECG after polychemotherapy was detected in 49 (40.1 %) patients with sensitivity 80 %, specificity 95 %, AUC 0.88 (95 % CI, 0.82-0.93). Conclusions: The side effects of cancer treatment may cause life -threatening risks. Early identification of cardiotoxicity plays a vital role in the solution of this problem. Using portable devices to detect early cardiotoxicity is a simple, convenient and affordable screening method, that can be used for promptly observation of patients.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Derivation of Respiratory Signals from Single-lead ECG
    Zhao, Yanna
    Zhao, Jie
    Li, Qun
    FBIE: 2008 INTERNATIONAL SEMINAR ON FUTURE BIOMEDICAL INFORMATION ENGINEERING, PROCEEDINGS, 2008, : 15 - 18
  • [22] Automated Detection of Obstructive Sleep Apnoea by Single-lead ECG through ELM Classification
    Sadr, Nadi
    de Chazal, Philip
    2014 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), VOL 41, 2014, 41 : 909 - 912
  • [23] Single-lead ECG based autonomic nervous system assessment for meditation monitoring
    Chanki Park
    Inchan Youn
    Sungmin Han
    Scientific Reports, 12 (1)
  • [24] Single-Lead Fetal ECG Extraction Based on a Parallel Marginalized Particle Filter
    Zhao, Zhidong
    Tong, Huiling
    Deng, Yanjun
    Xu, Wen
    Zhang, Yefei
    Ye, Haihui
    SENSORS, 2017, 17 (06)
  • [25] Single-lead ECG based autonomic nervous system assessment for meditation monitoring
    Park, Chanki
    Youn, Inchan
    Han, Sungmin
    SCIENTIFIC REPORTS, 2022, 12 (01):
  • [26] Arrhythmia Detection in Single-lead ECG by Combining Beat and Rhythm-level Information
    Pathangay, Vinod
    Rath, Satish Prasad
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 3236 - 3239
  • [27] Efficient wavelet-based ECG processing for single-lead FHR extraction
    Castillo, E.
    Morales, D. P.
    Botella, G.
    Garcia, A.
    Parrilla, L.
    Palma, A. J.
    DIGITAL SIGNAL PROCESSING, 2013, 23 (06) : 1897 - 1909
  • [28] ONLINE SEIZURE DETECTION IN ADULTS WITH TEMPORAL LOBE EPILEPSY USING SINGLE-LEAD ECG
    De Cooman, T.
    Carrette, E.
    Boon, P.
    Meurs, A.
    Van Huffel, S.
    2014 PROCEEDINGS OF THE 22ND EUROPEAN SIGNAL PROCESSING CONFERENCE (EUSIPCO), 2014, : 1532 - 1536
  • [29] A QRS Detection and R Point Recognition Method for Wearable Single-Lead ECG Devices
    Chen, Chieh-Li
    Chuang, Chun-Te
    SENSORS, 2017, 17 (09)
  • [30] Detection of Sleep Apnea from Single-Lead ECG: Comparison of Deep Learning Algorithms