A single-lead ECG based cardiotoxicity detection in patients on polychemotherapy

被引:1
|
作者
Mesitskaya, Dinara F. [2 ]
Fashafsha, Zaki Z. A. [1 ,4 ]
Poltavskaya, Maria G. [2 ]
Andreev, Denis A. [2 ]
Levshina, Anna R. [2 ]
Sultygova, Elizaveta A. [1 ]
Gognieva, Daria [1 ,2 ]
Chomakhidze, Petr [1 ,2 ]
Kuznetsova, Natalia [1 ]
Suvorov, Alexander [1 ]
Marina, Sekacheva [1 ,3 ]
Poddubskaya, Elena [2 ]
Novikova, Alena [2 ]
Bykova, Aleksandra [2 ]
Kopylov, Philipp [1 ,2 ]
机构
[1] Sechenov First Moscow State Med Univ, World Class Res Ctr Digital Biodesign & Personaliz, Moscow, Russia
[2] IM Sechenov First Moscow State Med Univ, Sechenov Univ, Dept Cardiol Funct & Ultrasound Diagnost NV Sklifo, Moscow, Russia
[3] IM Sechenov First Moscow State Med Univ, Inst Personalized Oncol, Ctr Digital Biodesign & Personalized Healthcare, Moscow, Russia
[4] St Bolshaya Pirogovskaya 6,Bldg 1, Moscow 119435, Russia
来源
IJC HEART & VASCULATURE | 2024年 / 50卷
关键词
Single-lead electrocardiogram; Chemotherapy; Cardiotoxicity; Left ventricular diastolic dysfunction; Atrial fibrillation; QTc prolongation;
D O I
10.1016/j.ijcha.2024.101336
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Anti -cancer treatment can be fraught with cardiovascular complications, which is the most common cause of death among oncological survivors. Without appropriate cardiomonitoring during anti -cancer treatment, it becomes challenging to detect early signs of cardiovascular complications. In order to achieve higher survival rates, it is necessary to monitor oncological patients outpatiently after anti -cancer treatment administration. In this regard, we aim to evaluate the efficacy of single -lead ECG remote monitoring to detect cardiotoxicity in cancer patients with minimal cardiovascular diseases after the first cycle of polychemotherapy. Materials and methods: The study included patients 162 patients over 18 years old with first diagnosed different types of solid tumors, planed for adjuvant (within 8 weeks after surgery) or neoadjuvant polychemotherapy. All patients were monitored, outpatiently, during 14-21 days (depending on the regimen of polychemotherapy) after polychemotherapy administration using single -lead ECG. Results: QTc > 500 mc prolongation was detected in 8 patients (6.6 %), first -diagnosed arial fibrillation was detected in 11 patients (9 %) in period after chemotherapy administration. Moreover, left ventricular diastolic dysfunction using single -lead ECG after polychemotherapy was detected in 49 (40.1 %) patients with sensitivity 80 %, specificity 95 %, AUC 0.88 (95 % CI, 0.82-0.93). Conclusions: The side effects of cancer treatment may cause life -threatening risks. Early identification of cardiotoxicity plays a vital role in the solution of this problem. Using portable devices to detect early cardiotoxicity is a simple, convenient and affordable screening method, that can be used for promptly observation of patients.
引用
收藏
页数:8
相关论文
共 50 条
  • [11] Six-lead device superior to single-lead smartwatch ECG in atrial fibrillation detection
    Scholten, Josca
    Jansen, Ward P. J.
    Horsthuis, Thomas
    Mahes, Anuska D.
    Winter, Michiel M.
    Zwinderman, Aeilko H.
    Keijer, Jan T.
    Minneboo, Madelon
    de Groot, Joris R.
    Bokma, Jouke P.
    AMERICAN HEART JOURNAL, 2022, 253 : 53 - 58
  • [12] KLT-based quality controlled compression of single-lead ECG
    Blanchett, T
    Kember, GC
    Fenton, GA
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1998, 45 (07) : 942 - 945
  • [13] A Novel Algorithm for the Automatic Detection of Sleep Apnea From Single-Lead ECG
    Varon, Carolina
    Caicedo, Alexander
    Testelmans, Dries
    Buyse, Bertien
    Van Huffel, Sabine
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2015, 62 (09) : 2269 - 2278
  • [14] FEASIBILITY OF SINGLE-ARM SINGLE-LEAD ECG BIOMETRICS
    Raj, Peter Sam
    Hatzinakos, Dimitrios
    2014 PROCEEDINGS OF THE 22ND EUROPEAN SIGNAL PROCESSING CONFERENCE (EUSIPCO), 2014, : 2525 - 2529
  • [15] A Sleep Apnea Detection Methodology Based on SE-ResNeXt Model Using Single-Lead ECG
    Vu, Tran Anh
    Phuong, Do Thi Thu
    Huy, Hoang Quang
    Kien, Nguyen Phan
    Huong, Pham Thi Viet
    JOURNAL OF BIOMIMETICS BIOMATERIALS AND BIOMEDICAL ENGINEERING, 2024, 64 : 85 - 93
  • [16] A NOVEL APPROACH OSA DETECTION USING SINGLE-LEAD ECG SCALOGRAM BASED ON DEEP NEURAL NETWORK
    Singh, Sinam Ajitkumar
    Majumder, Swanirbhar
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2019, 19 (04)
  • [17] Real-Time CNN Based ST Depression Episode Detection Using Single-Lead ECG
    Tiryaki, Erhan
    Sonawane, Akshay
    Tamil, Lakshman
    PROCEEDINGS OF THE 2021 TWENTY SECOND INTERNATIONAL SYMPOSIUM ON QUALITY ELECTRONIC DESIGN (ISQED 2021), 2021, : 566 - 570
  • [18] Sleep Apnea Detection from Single-Lead ECG Using Features Based on ECG-Derived Respiration (EDR) Signals
    Janbakhshi, P.
    Shamsollahi, M. B.
    IRBM, 2018, 39 (03) : 206 - 218
  • [19] Clinical relevance of the single-lead ECG of the Apple Watch
    Pepplinkhuizen, S.
    Hoeksema, W. F.
    Van der Stuijt, W.
    Smeding, L.
    Wilde, A. A. M.
    Knops, R. E.
    EUROPEAN HEART JOURNAL, 2022, 43 : 2803 - 2803
  • [20] Feature Extraction for Heartbeat Classification in Single-Lead ECG
    Bogatinovski, J.
    Kocev, D.
    Rashkovska, A.
    2019 42ND INTERNATIONAL CONVENTION ON INFORMATION AND COMMUNICATION TECHNOLOGY, ELECTRONICS AND MICROELECTRONICS (MIPRO), 2019, : 320 - 325