Load bearing capacity of 3-unit screw-retained implant-supported fixed dental prostheses with a mesial and distal cantilever on a single implant: A comparative in vitro study

被引:3
|
作者
Molinero-Mourelle, Pedro [1 ]
Abou-Ayash, Samir [1 ]
Bragger, Urs [1 ]
Schimmel, Martin [1 ,2 ]
Ozcan, Mutlu [3 ]
Yilmaz, Burak [1 ,4 ,5 ]
Buser, Ramona [1 ]
Al-Haj Husain, Nadin [1 ,3 ]
机构
[1] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Freiburgstr 7, CH-3010 Bern, Switzerland
[2] Univ Geneva, Div Gerodontol & Removable Prosthodont, Geneva, Switzerland
[3] Univ Zurich, Ctr Dent Med, Clin Masticatory Disorders & Dent Biomat, Zurich, Switzerland
[4] Univ Bern, Sch Dent Med, Dept Restorat Prevent & Pediat Dent, Bern, Switzerland
[5] Ohio State Univ, Coll Dent, Div Restorat & Prosthet Dent, Columbus, OH USA
关键词
Dental implant; Dental restoration failure; Fatigue; Implant-supported dental prosthesis; Load-bearing capacity; Prosthodontics; Screw-retained; PARTIAL DENTURES; MECHANICAL STABILITY; COMPLICATION RATES; CLINICAL-OUTCOMES; FLEXURAL STRENGTH; ABUTMENT DESIGN; ANTERIOR REGION; ZIRCONIA; CROWNS; SURVIVAL;
D O I
10.1016/j.jmbbm.2024.106395
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objectives: To assess the mechanical durability of monolithic zirconia implant-supported fixed dental prostheses (iFDP) design on one implant, with a distal and a mesial extension cantilever bonded to a titanium base compared to established designs on two implants. Materials and methods: Roxolid Tissue level (TL), and tissue level x (TLX) implants were used to manufacture screw-retained 3-unit iFDPs (n = 60, n = 10 per group), with following configurations (X: Cantilever; I: Implant, T: Test group, C: Control group): T1: X-I-X (TL); T2: X-I-X (TLX); T3: I-I-X (TL); T4: I-I-X (TLX); C1: I-X-I (TL); C2: I-X-I (TLX). The iFDPs were thermomechanically aged and subsequently loaded until fracture using a universal testing machine. The failure load at first crack (F-initial) and at catastrophic fracture (F-max) were measured and statistical evaluation was performed using two-way ANOVA and Tukey's post-hoc tests. Results: The mean values ranged between 190 +/- 73 and 510 +/- 459 N for F-initial groups, and between 468 +/- 76 and 1579 +/- 249 N for F-max, respectively. Regarding F-initial, neither the implant type, nor the iFDP configuration significantly influenced measured failure loads (all p > 0.05). The choice of implant type did not show any significant effect (p > 0.05), while reconstruction design significantly affected F-max data (I-I-X-a < X-I-X-b < I-X-I (c)) (p < 0.05). The mesial and distal extension groups (X-I-X) showed fractures only at the cantilever extension site, while the distal extension group (I-I-X) showed one abutment and one connector fracture at the implant/reconstruction interface. Conclusion: Results suggest that iFDPs with I-X-I design can be recommended regardless of tested implant type followed by the mesial and distal extension design on one implant abutment (X-I-X).
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Complication and Failure Rates with Implant-Supported Fixed Dental Prostheses and Single Crowns: A 10-Year Retrospective Study
    Wittneben, Julia-Gabriela
    Buser, Daniel
    Salvi, Giovanni E.
    Buergin, Walter
    Hicklin, Stefan
    Braegger, Urs
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2014, 16 (03) : 356 - 364
  • [42] Analysis of implant-supported cantilever fixed partial denture: An in vitro comparative study on vertical misfit, stress distribution, and cantilever fracture strength
    Peixoto, Raniel Fernandes
    Tonin, Bruna Santos Honorio
    Pinto-Fiamengui, Livia Maria Sales
    Freitas-Pontes, Karina Mattes
    Regis, Romulo Rocha
    de Mattos, Maria da Gloria Chiarello
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024, 33 (06): : 584 - 592
  • [43] Evaluation and comparison of vertical marginal fit of three different types of multiunit screw-retained framework fabricated for an implant-supported prosthesis - An in vitro study
    Singh, Mahima
    Yadav, Bhupender Kumar
    Phukela, Sumit Singh
    Ritwal, Pankaj
    Nagpal, Abhishek
    Saluja, Pulin
    THE JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2022, 22 (03) : 240 - 248
  • [44] Five-year randomized controlled clinical study comparing cemented and screw-retained zirconia-based implant-supported single crowns
    Kraus, Riccardo D.
    Espuelas, Catharina
    Hammerle, Christoph H. F.
    Jung, Ronald E.
    Sailer, Irena
    Thoma, Daniel S.
    CLINICAL ORAL IMPLANTS RESEARCH, 2022, 33 (05) : 537 - 547
  • [45] A Retrospective Analysis of Mandibular Bone Height Changes Associated with 81 Screw-Retained Implant-Supported Prostheses with Distal Cantilevers: A Long-Term Follow-up Analysis
    Dhima, Matilda
    Balshi, Thomas
    Wolfinger, Glenn
    Petropoulos, Vicki C.
    Balshi, Stephen
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (03) : 854 - 859
  • [46] Clinical performance of posterior monolithic zirconia implant-supported fixed dental prostheses with angulated screw channels: A 3-year prospective cohort study
    Di Fiore, Adolfo
    Granata, Stefano
    Monaco, Carlo
    Stellini, Edoardo
    Yilmaz, Burak
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 129 (04): : 566 - 572
  • [47] Accuracy of photogrammetric imaging versus conventional impressions for complete arch implant-supported fixed dental prostheses: A comparative clinical study
    Zhang, Yi-Jie
    Qian, Shu-Jiao
    Lai, Hong-Chang
    Shi, Jun-Yu
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 130 (02): : 212 - 218
  • [48] Full arch digital scanning systems performances for implant-supported fixed dental prostheses: a comparative study of 8 intraoral scanners
    Di Fiore, Adolfo
    Meneghello, Roberto
    Graiff, Lorenzo
    Savio, Gianpaolo
    Vigolo, Paolo
    Monaco, Carlo
    Stellini, Edoardo
    JOURNAL OF PROSTHODONTIC RESEARCH, 2019, 63 (04) : 396 - 403
  • [49] VERTICAL LOAD DISTRIBUTION ON A 3-UNIT PROSTHESIS SUPPORTED BY A NATURAL TOOTH AND A SINGLE BRANEMARK IMPLANT - AN IN-VIVO STUDY
    RANGERT, B
    GUNNE, J
    GLANTZ, PO
    SVENSSON, A
    CLINICAL ORAL IMPLANTS RESEARCH, 1995, 6 (01) : 40 - 46
  • [50] Comparative Evaluation of Load-Bearing Capacity and Fracture Analysis of PEEK and Zirconia Three-Unit Fixed Dental Prostheses: An In Vitro Study
    Jain, Radhika A.
    Gupta, Rekha
    Verma, Mahesh
    Nanda, Aditi
    Gill, Shubhra
    Mehra, Rashmi
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2022, 35 (02) : 225 - 232