Load bearing capacity of 3-unit screw-retained implant-supported fixed dental prostheses with a mesial and distal cantilever on a single implant: A comparative in vitro study

被引:3
|
作者
Molinero-Mourelle, Pedro [1 ]
Abou-Ayash, Samir [1 ]
Bragger, Urs [1 ]
Schimmel, Martin [1 ,2 ]
Ozcan, Mutlu [3 ]
Yilmaz, Burak [1 ,4 ,5 ]
Buser, Ramona [1 ]
Al-Haj Husain, Nadin [1 ,3 ]
机构
[1] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Freiburgstr 7, CH-3010 Bern, Switzerland
[2] Univ Geneva, Div Gerodontol & Removable Prosthodont, Geneva, Switzerland
[3] Univ Zurich, Ctr Dent Med, Clin Masticatory Disorders & Dent Biomat, Zurich, Switzerland
[4] Univ Bern, Sch Dent Med, Dept Restorat Prevent & Pediat Dent, Bern, Switzerland
[5] Ohio State Univ, Coll Dent, Div Restorat & Prosthet Dent, Columbus, OH USA
关键词
Dental implant; Dental restoration failure; Fatigue; Implant-supported dental prosthesis; Load-bearing capacity; Prosthodontics; Screw-retained; PARTIAL DENTURES; MECHANICAL STABILITY; COMPLICATION RATES; CLINICAL-OUTCOMES; FLEXURAL STRENGTH; ABUTMENT DESIGN; ANTERIOR REGION; ZIRCONIA; CROWNS; SURVIVAL;
D O I
10.1016/j.jmbbm.2024.106395
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objectives: To assess the mechanical durability of monolithic zirconia implant-supported fixed dental prostheses (iFDP) design on one implant, with a distal and a mesial extension cantilever bonded to a titanium base compared to established designs on two implants. Materials and methods: Roxolid Tissue level (TL), and tissue level x (TLX) implants were used to manufacture screw-retained 3-unit iFDPs (n = 60, n = 10 per group), with following configurations (X: Cantilever; I: Implant, T: Test group, C: Control group): T1: X-I-X (TL); T2: X-I-X (TLX); T3: I-I-X (TL); T4: I-I-X (TLX); C1: I-X-I (TL); C2: I-X-I (TLX). The iFDPs were thermomechanically aged and subsequently loaded until fracture using a universal testing machine. The failure load at first crack (F-initial) and at catastrophic fracture (F-max) were measured and statistical evaluation was performed using two-way ANOVA and Tukey's post-hoc tests. Results: The mean values ranged between 190 +/- 73 and 510 +/- 459 N for F-initial groups, and between 468 +/- 76 and 1579 +/- 249 N for F-max, respectively. Regarding F-initial, neither the implant type, nor the iFDP configuration significantly influenced measured failure loads (all p > 0.05). The choice of implant type did not show any significant effect (p > 0.05), while reconstruction design significantly affected F-max data (I-I-X-a < X-I-X-b < I-X-I (c)) (p < 0.05). The mesial and distal extension groups (X-I-X) showed fractures only at the cantilever extension site, while the distal extension group (I-I-X) showed one abutment and one connector fracture at the implant/reconstruction interface. Conclusion: Results suggest that iFDPs with I-X-I design can be recommended regardless of tested implant type followed by the mesial and distal extension design on one implant abutment (X-I-X).
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Screw-retained ceramic-veneered/monolithic zirconia partial implant-supported fixed dental prostheses: A 5 to 10-year retrospective study on survival and complications
    Zhang, Yifan
    Luo, Jia
    Di, Ping
    Chen, Bo
    Li, Jianhui
    Yu, Ziyang
    Lin, Ye
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024, 33 (03): : 221 - 230
  • [22] Retention Forces of Implant-Supported Single Crowns and Fixed Dental Prostheses after Cementation: An In-Vitro Study
    Bishti, Shaza
    Siouri, Jousef
    Wolfart, Stefan
    Tuna, Taskin
    ORAL, 2022, 2 (01): : 29 - 40
  • [23] A 3-year prospective cohort study on mandibular anterior cantilever restorations associated with screw-retained implant-supported prosthesis: An in vivo study
    Nelluri, Vizaikumar Vasudha
    Roseme, Kandathilparambil Maria L.
    Gedela, Rajani Kumar
    THE JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2021, 21 (02) : 150 - 160
  • [24] Oral and Periodontal Risk Factors of Prosthetic Success for 3-Unit Natural Tooth-Supported Bridges versus Implant-Supported Fixed Dental Prostheses
    Cristea, Ioana
    Agop-Forna, Doriana
    Martu, Maria-Alexandra
    Dascalu, Cristina
    Topoliceanu, Claudiu
    Torok, Roland
    Torok, Bianca
    Bardis, Dimitrios
    Bardi, Panagiota Moulavasili
    Forna, Norina
    DIAGNOSTICS, 2023, 13 (05)
  • [25] An in vitro study on compensation of mismatch of screw versus cement-retained implant supported fixed prostheses
    Pietrabissa, R
    Gionso, L
    Quaglini, V
    Di Martino, E
    Simion, M
    CLINICAL ORAL IMPLANTS RESEARCH, 2000, 11 (05) : 448 - 457
  • [26] Acoustic resonance frequency analysis for evaluating prosthetic screw stability in splinted implant-supported fixed dental prostheses: An in vitro study
    Guo, Jiaer
    Wang, Xiaolu
    Liu, Zhixin
    Zhou, Jianying
    Wang, Lin
    JOURNAL OF PROSTHETIC DENTISTRY, 2025, 133 (02):
  • [27] Survival and complications of implant-supported cantilever fixed dental prostheses with zirconia and metal frameworks: A retrospective cohort study
    Horsch, Laura
    Kronsteiner, Dorothea
    Rammelsberg, Peter
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2022, 24 (05) : 621 - 629
  • [28] The prosthetic screw loosening of two-implant supported screw-retained fixed dental prostheses in the posterior region: A retrospective evaluation and finite element analysis
    Chen, Jianyu
    Wang, Lin
    Yang, Lijia
    Zhang, Xiao
    Huang, Baoxin
    Li, Jingping
    JOURNAL OF BIOMECHANICS, 2021, 122
  • [29] Biomechanics of 3-implant-supported and 4-implant-supported mandibular screw-retained prostheses: A 3D finite element analysis study
    Elsayyad, Ahmed A.
    Abbas, Nadia A.
    AbdelNabi, Nouran M.
    Osman, Reham B.
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (01): : 68.e1 - 68.e10
  • [30] Clinical Evaluation of Immediate Loading of Electroeroded Screw-Retained Titanium Fixed Prostheses Supported by Tilted Implant: A Multicenter Retrospective Study
    Acocella, Alessandro
    Ercoli, Carlo
    Geminiani, Alessandro
    Feng, Changyong
    Billi, Mauro
    Acocella, Gabriele
    Giannini, Domenico
    Sacco, Roberto
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2012, 14 : e98 - e108