Free-breathing simultaneous water-fat separation and T1 mapping of the whole liver (SWALI) with isotropic resolution using 3D golden-angle radial trajectory

被引:6
|
作者
Wang, Yajie [1 ]
Qi, Haikun [2 ]
Wang, Yishi [3 ]
Xiao, Ming [4 ,5 ]
Xiang, Canhong [5 ]
Dong, Jiahong [5 ]
Chen, Huijun [1 ]
机构
[1] Tsinghua Univ, Ctr Biomed Imaging Res, Sch Med, Dept Biomed Engn, Beijing 100084, Peoples R China
[2] ShanghaiTech Univ, Sch Biomed Engn, Shanghai, Peoples R China
[3] Philips Healthcare, Beijing, Peoples R China
[4] Shandong Univ, Dept Hepatobiliary Surg, Hosp 2, Jinan, Peoples R China
[5] Tsinghua Univ, Beijing Tsinghua Changgung Hosp, Hepatopancreato Biliary Ctr, Sch Clin Med, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
Water-fat separation; fat fraction (FF); T1; mapping; liver; INVERSION-RECOVERY MOLLI; QUANTIFICATION; T-1; PROTON; RECONSTRUCTION; MRI;
D O I
10.21037/qims-22-748
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Conventional liver T1 mapping techniques are typically performed under breath-holding conditions; they have limited slice coverage and often rely on multiple acquisitions. Furthermore, liver fat affects the accuracy of T1 quantification. Therefore, we aim to propose a free-breathing technique for simultaneous water-fat separation and T1 mapping of the whole liver (SWALI) in a single scan.Methods: The proposed SWALI sequence included an inversion recovery (IR) preparation pulse followed by a series of multiecho three-dimensional (3D) golden-angle radial acquisitions. For each echo time (TE), a series of images containing a mix of water and fat were reconstructed using a sliding window method. For each inversion time (TI), water and fat were separated, and then water and fat T1 estimation was conducted. The fat fraction (FF) was calculated based on the last TI image. The FF and water T1 quantification accuracy were compared with the gold standard sequences in the phantom. The in vivo feasibility was tested in 9 healthy volunteers, 2 patients with fatty liver, and 3 patients with hepatocellular carcinoma (HCC). The reproducibility was evaluated in the patients with fatty liver and in the healthy volunteers.Results: The mean FF and the mean water T1 values obtained by the SWALI sequence showed good agreements with chemical shift-encoded magnetic resonance imaging (CSE-MRI; r=0.998; P<0.001) and fat-suppressed (FS) IR-spin echo (SE; r=0.997; P<0.001) in the phantom. For the patients with fatty liver and the healthy volunteers, the SWALI sequence showed no significant difference with CSE-MRI in FF quantification (P=0.53). In T1 quantification, comparable T1 values were obtained with the SWALI sequence and modified Look-Locker inversion recovery (MOLLI; P=0.10) in healthy volunteers, while the water T1 estimated by the SWALI sequence was significantly lower than the water-fat compound T1 estimated by MOLLI (P<0.001) in patients with fatty liver. In the reproducibility study, the intraclass correlation coefficients (ICCs) for the estimated FF and water T1 were 0.997 and 0.943, respectively. Water T1 of the patients with HCC calculated using the SWALI sequence showed a significant reduction after the contrast administration (P<0.001). Conclusions: Free-breathing water-fat separation and T1 mapping of the whole liver with 2.5 mm isotropic spatial resolution were achieved simultaneously using the SWALI sequence in a 5-min scan.
引用
收藏
页码:912 / 923
页数:12
相关论文
共 38 条
  • [1] Simultaneous whole-liver water T1 and T2 mapping with isotropic resolution during free-breathing
    Stelter, Jonathan
    Weiss, Kilian
    Steinhelfer, Lisa
    Spieker, Veronika
    Moquillaza, Elizabeth Huaroc
    Zhang, Weitong
    Makowski, Marcus R.
    Schnabel, Julia A.
    Kainz, Bernhard
    Braren, Rickmer F.
    Karampinos, Dimitrios C.
    NMR IN BIOMEDICINE, 2024, 37 (12)
  • [2] Free-breathing 3D whole-heart joint T1/T2 mapping and water/fat imaging at 0.55 T
    Si, Dongyue
    Crabb, Michael G.
    Kunze, Karl P.
    Littlewood, Simon J.
    Prieto, Claudia
    Botnar, Rene M.
    MAGNETIC RESONANCE IN MEDICINE, 2024, 92 (04) : 1511 - 1524
  • [3] Accelerated free-breathing whole-heart 3D T2 mapping with high isotropic resolution
    Bustin, Aurelien
    Milotta, Giorgia
    Ismail, Tevfik F.
    Neji, Radhouene
    Botnar, Rene M.
    Prieto, Claudia
    MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (03) : 988 - 1002
  • [4] Accelerated 3D free-breathing high-resolution myocardial T1ρ mapping at 3 Tesla
    Qi, Haikun
    Lv, Zhenfeng
    Hu, Junpu
    Xu, Jian
    Botnar, Rene
    Prieto, Claudia
    Hu, Peng
    MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (06) : 2520 - 2531
  • [5] 3D B1+corrected simultaneous myocardial T1 and T1ρ mapping with subject-specific respiratory motion correction and water-fat separation
    Qi, Haikun
    Lv, Zhenfeng
    Diao, Jiameng
    Tao, Xiaofeng
    Hu, Junpu
    Xu, Jian
    Botnar, Rene
    Prieto, Claudia
    Hu, Peng
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (02) : 751 - 760
  • [6] 3D B1+corrected simultaneous myocardial T1 and T1ρ mapping with subject-specific respiratory motion correction and water-fat separation
    Qi, Haikun
    Lv, Zhenfeng
    Diao, Jiameng
    Tao, Xiaofeng
    Hu, Junpu
    Xu, Jian
    Botnar, Rene
    Prieto, Claudia
    Hu, Peng
    MAGNETIC RESONANCE IN MEDICINE, 2024,
  • [7] Free-running 3D whole heart myocardial T1 mapping with isotropic spatial resolution
    Qi, Haikun
    Jaubert, Olivier
    Bustin, Aurelien
    Cruz, Gastao
    Chen, Huijun
    Botnar, Rene
    Prieto, Claudia
    MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (04) : 1331 - 1342
  • [8] Free-breathing liver fat quantification using a multiecho 3D stack-of-radial technique
    Armstrong, Tess
    Dregely, Isabel
    Stemmer, Alto
    Han, Fei
    Natsuaki, Yutaka
    Sung, Kyunghyun
    Wu, Holden H.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (01) : 370 - 382
  • [9] Projection-based respiratory-resolved left ventricular volume measurements in patients using free-breathing double golden-angle 3D radial acquisition
    Karen Holst
    Alexander Fyrdahl
    Kenneth Caidahl
    Martin Ugander
    Andreas Sigfridsson
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2019, 32 : 331 - 341
  • [10] Projection-based respiratory-resolved left ventricular volume measurements in patients using free-breathing double golden-angle 3D radial acquisition
    Holst, Karen
    Fyrdahl, Alexander
    Caidahl, Kenneth
    Ugander, Martin
    Sigfridsson, Andreas
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2019, 32 (03) : 331 - 341