Free-breathing simultaneous water-fat separation and T1 mapping of the whole liver (SWALI) with isotropic resolution using 3D golden-angle radial trajectory

被引:6
|
作者
Wang, Yajie [1 ]
Qi, Haikun [2 ]
Wang, Yishi [3 ]
Xiao, Ming [4 ,5 ]
Xiang, Canhong [5 ]
Dong, Jiahong [5 ]
Chen, Huijun [1 ]
机构
[1] Tsinghua Univ, Ctr Biomed Imaging Res, Sch Med, Dept Biomed Engn, Beijing 100084, Peoples R China
[2] ShanghaiTech Univ, Sch Biomed Engn, Shanghai, Peoples R China
[3] Philips Healthcare, Beijing, Peoples R China
[4] Shandong Univ, Dept Hepatobiliary Surg, Hosp 2, Jinan, Peoples R China
[5] Tsinghua Univ, Beijing Tsinghua Changgung Hosp, Hepatopancreato Biliary Ctr, Sch Clin Med, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
Water-fat separation; fat fraction (FF); T1; mapping; liver; INVERSION-RECOVERY MOLLI; QUANTIFICATION; T-1; PROTON; RECONSTRUCTION; MRI;
D O I
10.21037/qims-22-748
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Conventional liver T1 mapping techniques are typically performed under breath-holding conditions; they have limited slice coverage and often rely on multiple acquisitions. Furthermore, liver fat affects the accuracy of T1 quantification. Therefore, we aim to propose a free-breathing technique for simultaneous water-fat separation and T1 mapping of the whole liver (SWALI) in a single scan.Methods: The proposed SWALI sequence included an inversion recovery (IR) preparation pulse followed by a series of multiecho three-dimensional (3D) golden-angle radial acquisitions. For each echo time (TE), a series of images containing a mix of water and fat were reconstructed using a sliding window method. For each inversion time (TI), water and fat were separated, and then water and fat T1 estimation was conducted. The fat fraction (FF) was calculated based on the last TI image. The FF and water T1 quantification accuracy were compared with the gold standard sequences in the phantom. The in vivo feasibility was tested in 9 healthy volunteers, 2 patients with fatty liver, and 3 patients with hepatocellular carcinoma (HCC). The reproducibility was evaluated in the patients with fatty liver and in the healthy volunteers.Results: The mean FF and the mean water T1 values obtained by the SWALI sequence showed good agreements with chemical shift-encoded magnetic resonance imaging (CSE-MRI; r=0.998; P<0.001) and fat-suppressed (FS) IR-spin echo (SE; r=0.997; P<0.001) in the phantom. For the patients with fatty liver and the healthy volunteers, the SWALI sequence showed no significant difference with CSE-MRI in FF quantification (P=0.53). In T1 quantification, comparable T1 values were obtained with the SWALI sequence and modified Look-Locker inversion recovery (MOLLI; P=0.10) in healthy volunteers, while the water T1 estimated by the SWALI sequence was significantly lower than the water-fat compound T1 estimated by MOLLI (P<0.001) in patients with fatty liver. In the reproducibility study, the intraclass correlation coefficients (ICCs) for the estimated FF and water T1 were 0.997 and 0.943, respectively. Water T1 of the patients with HCC calculated using the SWALI sequence showed a significant reduction after the contrast administration (P<0.001). Conclusions: Free-breathing water-fat separation and T1 mapping of the whole liver with 2.5 mm isotropic spatial resolution were achieved simultaneously using the SWALI sequence in a 5-min scan.
引用
收藏
页码:912 / 923
页数:12
相关论文
共 38 条
  • [11] 3D whole-heart isotropic-resolution motion-compensated joint T1/T2mapping and water/fat imaging
    Milotta, Giorgia
    Bustin, Aurelien
    Jaubert, Olivier
    Neji, Radhouene
    Prieto, Claudia
    Botnar, Rene M.
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (06) : 3009 - 3026
  • [12] Free-running simultaneous myocardial T1/T2 mapping and cine imaging with 3D whole-heart coverage and isotropic spatial resolution
    Qi, Haikun
    Bustin, Aurelien
    Cruz, Gastao
    Jaubert, Olivier
    Chen, Huijun
    Botnar, Rene M.
    Prieto, Claudia
    MAGNETIC RESONANCE IMAGING, 2019, 63 : 159 - 169
  • [13] 3D joint T1/T1ρ/T2 mapping and water-fat imaging for contrast-agent free myocardial tissue characterization at 1.5T
    Crabb, Michael G.
    Kunze, Karl P.
    Littlewood, Simon J.
    Tripp, Donovan
    Fotaki, Anastasia
    Prieto, Claudia
    Botnar, Rene M.
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (06) : 2297 - 2310
  • [14] Accelerated free-breathing 3D T1 cardiovascular magnetic resonance using multicoil compressed sensing
    Iyer, Srikant Kamesh
    Moon, Brianna
    Hwuang, Eileen
    Han, Yuchi
    Solomon, Michael
    Litt, Harold
    Witschey, Walter R.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2019, 21 (1)
  • [15] Accelerated free-breathing 3D T1ρ cardiovascular magnetic resonance using multicoil compressed sensing
    Srikant Kamesh Iyer
    Brianna Moon
    Eileen Hwuang
    Yuchi Han
    Michael Solomon
    Harold Litt
    Walter R. Witschey
    Journal of Cardiovascular Magnetic Resonance, 21
  • [16] Free-Breathing Quantitative Dynamic Contrast-Enhanced Magnetic Resonance Imaging in a Rat Liver Tumor Model Using Dynamic Radial T1 Mapping
    Braren, Rickmer
    Curcic, Jelena
    Remmele, Stefanie
    Altomonte, Jennifer
    Ebert, Oliver
    Rummeny, Ernst J.
    Steingoetter, Andreas
    INVESTIGATIVE RADIOLOGY, 2011, 46 (10) : 624 - 631
  • [17] Clinical Evaluation of Free-Breathing Contrast-Enhanced T1w MRI of the Liver using Pseudo Golden Angle Radial k-Space Sampling
    Hedderich, Dennis M.
    Weiss, Kilian
    Spiro, Judith E.
    Giese, Daniel
    Beck, Gabriele M.
    Maintz, David
    Persigehl, Thorsten
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2018, 190 (07): : 601 - 609
  • [18] Clinical application of free-breathing 3D whole heart late gadolinium enhancement cardiovascular magnetic resonance with high isotropic spatial resolution using Compressed SENSE
    Pennig, Lenhard
    Lennartz, Simon
    Wagner, Anton
    Sokolowski, Marcel
    Gajzler, Matej
    Ney, Svenja
    Laukamp, Kai Roman
    Persigehl, Thorsten
    Bunck, Alexander Christian
    Maintz, David
    Weiss, Kilian
    Naehle, Claas Philip
    Doerner, Jonas
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2020, 22 (01)
  • [19] Clinical application of free-breathing 3D whole heart late gadolinium enhancement cardiovascular magnetic resonance with high isotropic spatial resolution using Compressed SENSE
    Lenhard Pennig
    Simon Lennartz
    Anton Wagner
    Marcel Sokolowski
    Matej Gajzler
    Svenja Ney
    Kai Roman Laukamp
    Thorsten Persigehl
    Alexander Christian Bunck
    David Maintz
    Kilian Weiss
    Claas Philip Naehle
    Jonas Doerner
    Journal of Cardiovascular Magnetic Resonance, 22
  • [20] 3D R2* mapping of the placenta during early gestation using free-breathing multiecho stack-of-radial MRI at 3T
    Armstrong, Tess
    Liu, Dapeng
    Martin, Thomas
    Masamed, Rinat
    Janzen, Carla
    Wong, Cass
    Chanlaw, Teresa
    Devaskar, Sherin U.
    Sung, Kyunghyun
    Wu, Holden H.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 49 (01) : 291 - 303