CO2 Measurement under Different Pressure and Vibration Conditions Using Tunable Diode Laser Absorption Spectroscopy

被引:1
|
作者
Ban, Deyue [1 ]
Li, Nan [1 ]
Zheng, Yongqiu [1 ]
Xue, Chenyang [1 ]
机构
[1] North Univ China, State Key Lab Dynam Measurement Technol, Taiyuan 030051, Peoples R China
关键词
tunable laser absorption spectroscopy; WMS; pressure; vibration; flue gas duct; TEMPERATURE; TDLAS;
D O I
10.3390/photonics11020146
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The greenhouse effect resulting from fuel combustion has drawn growing attention, and CO2 emissions from fossil fuel power stations are one of the main sources of greenhouse gases. It is crucial to monitor the concentration of CO2 in the flue gas ducts of these stations. However, pressure and vibration caused by the combustion of boilers make the measurement of CO2 in flue gas ducts extremely challenging. In this study, tunable diode laser absorption spectroscopy (TDLAS) combined with Wave Modulation Spectroscopy (WMS) was employed to measure the concentration of CO2 under different pressure and vibration conditions in the laboratory. The absorption line of CO2 at the wavenumber 6357.38 cm(-1) was recorded under varying pressure conditions ranging from 0 to 1.4 atm, acceleration conditions ranging from 0 to 7.7 m/s(2), and a combination of both. Firstly, a negative linear correlation was found between the pressure and the amplitude of the second harmonic, with a maximum relative error of 4.645% observed at a pressure of 1.4 atm. Secondly, the maximum acceleration that the system can withstand was determined to be 7.3 m/s(2), as it was not possible to provide a sufficiently low fitting error at higher accelerations. For the combined effects of the pressure and vibration, a dramatic increase in the relative error of amplitude can be observed within the acceleration range of 5.0 similar to 6.0 m/s(2) while under the pressure conditions of 0.6 atm, 1.0 atm, and 1.4 atm. Moreover, the maximum endurable acceleration decreases with the increase in pressure, which infers that effective measurements can be achieved when the acceleration is below 5 m/s(2) within the pressure range of 0 similar to 1.4 atm. This suggests that TDLAS combined with WMS possesses a potential for online measuring of CO2 concentrations in flue gas ducts within a certain acceleration range. This work can provide some insights for stable gas detection using TDLAS under varied pressure and vibration conditions.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Spatial resolved temperature measurement based on absorption spectroscopy using a single tunable diode laser
    Xilong YuFei LiLihong ChenXinyu Zhang Key Laboratory of High Temperature Gas Dynamics Institute of MechanicsChinese Academy of Sciences BeijingChina
    Acta Mechanica Sinica, 2010, 26 (01) : 147 - 149
  • [42] Measurement of exhaled nitric oxide in beef cattle using tunable diode laser absorption spectroscopy
    Roller, C. B.
    Holland, B. P.
    McMillen, G.
    Step, D. L.
    Krehbiel, C. R.
    Namjou, K.
    McCann, P. J.
    APPLIED OPTICS, 2007, 46 (08) : 1333 - 1342
  • [43] Spatial resolved temperature measurement based on absorption spectroscopy using a single tunable diode laser
    Xilong Yu
    Fei Li
    Lihong Chen
    Xinyu Zhang
    Acta Mechanica Sinica, 2010, 26 : 147 - 149
  • [44] Spatial resolved temperature measurement based on absorption spectroscopy using a single tunable diode laser
    Xilong Yu.Fei Li.Lihong Chen.Xinyu Zhang Key Laboratory of High Temperature Gas Dynamics
    Acta Mechanica Sinica, 2010, (01) : 147 - 149
  • [45] Methods of tunable diode laser absorption saturation spectroscopy to gas sensing under optically thick conditions
    Nie, Wei
    Xu, Zhenyu
    Rao, Gangfu
    Lin, Xiao
    Lu, Jidong
    Dong, Meirong
    Kan, Ruifeng
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2021, 63 (08) : 2063 - 2067
  • [46] Measurement of CO2 and Ultrasonic Vibration Based on Tunable Fiber Ring Laser
    Lalam, Nageswara
    Lu, Ping
    Lu, Fei
    Hong, Tao
    Buric, Michael P.
    IEEE ACCESS, 2020, 8 : 193340 - 193346
  • [47] The Experimental Research on In-Situ Detection for Dissolved CO2 in Seawater Based on Tunable Diode Laser Absorption Spectroscopy
    Du Bao-lu
    Li Meng
    Guo Jin-jia
    Zhang Zhi-hao
    Ye Wang-quan
    Zheng Rong-er
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42 (04) : 1264 - 1269
  • [48] Measuring field-scale isotopic CO2 fluxes with tunable diode laser absorption spectroscopy and micrometeorological techniques
    Griffis, TJ
    Baker, JM
    Sargent, SD
    Tanner, BD
    Zhang, J
    AGRICULTURAL AND FOREST METEOROLOGY, 2004, 124 (1-2) : 15 - 29
  • [49] High speed temperature, pressure, and water vapor concentration measurement in explosive fireballs using tunable diode laser absorption spectroscopy
    Murzyn, Christopher
    Sims, Adam
    Krier, Herman
    Glumac, Nick
    OPTICS AND LASERS IN ENGINEERING, 2018, 110 : 186 - 192
  • [50] The Experimental Research on In-Situ Detection for Dissolved CO2 in Seawater Based on Tunable Diode Laser Absorption Spectroscopy
    Du, Bao-Lu
    Li, Meng
    Guo, Jin-Jia
    Zhang, Zhi-Hao
    Ye, Wang-Quan
    Zheng, Rong-Er
    Guang Pu Xue Yu Guang Pu Fen Xi/Spectroscopy and Spectral Analysis, 2022, 42 (04): : 1264 - 1269