The greenhouse effect resulting from fuel combustion has drawn growing attention, and CO2 emissions from fossil fuel power stations are one of the main sources of greenhouse gases. It is crucial to monitor the concentration of CO2 in the flue gas ducts of these stations. However, pressure and vibration caused by the combustion of boilers make the measurement of CO2 in flue gas ducts extremely challenging. In this study, tunable diode laser absorption spectroscopy (TDLAS) combined with Wave Modulation Spectroscopy (WMS) was employed to measure the concentration of CO2 under different pressure and vibration conditions in the laboratory. The absorption line of CO2 at the wavenumber 6357.38 cm(-1) was recorded under varying pressure conditions ranging from 0 to 1.4 atm, acceleration conditions ranging from 0 to 7.7 m/s(2), and a combination of both. Firstly, a negative linear correlation was found between the pressure and the amplitude of the second harmonic, with a maximum relative error of 4.645% observed at a pressure of 1.4 atm. Secondly, the maximum acceleration that the system can withstand was determined to be 7.3 m/s(2), as it was not possible to provide a sufficiently low fitting error at higher accelerations. For the combined effects of the pressure and vibration, a dramatic increase in the relative error of amplitude can be observed within the acceleration range of 5.0 similar to 6.0 m/s(2) while under the pressure conditions of 0.6 atm, 1.0 atm, and 1.4 atm. Moreover, the maximum endurable acceleration decreases with the increase in pressure, which infers that effective measurements can be achieved when the acceleration is below 5 m/s(2) within the pressure range of 0 similar to 1.4 atm. This suggests that TDLAS combined with WMS possesses a potential for online measuring of CO2 concentrations in flue gas ducts within a certain acceleration range. This work can provide some insights for stable gas detection using TDLAS under varied pressure and vibration conditions.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Indoor CO2 Online Monitoring Based on Open-Path Tunable Diode Laser Absorption Spectroscopy
    Huang Qi
    Wang Qing
    Wang Kaitao
    Wang Congshan
    Cui Ruyue
    Wu Hongpeng
    Dong Lei
    LASER & OPTOELECTRONICS PROGRESS, 2024, 61 (05)
  • [32] Tunable diode laser absorption spectroscopy for stable isotope studies of ecosystem-atmosphere CO2 exchange
    Bowling, DR
    Sargent, SD
    Tanner, BD
    Ehleringer, JR
    AGRICULTURAL AND FOREST METEOROLOGY, 2003, 118 (1-2) : 1 - 19
  • [33] Combustion of aluminum powder using CO2 laser in O2/CO2 atmosphere under different pressure conditions
    Qili Qiu
    Yunan Zhou
    Jianzhong Liu
    Wei Shi
    Weijuan Yang
    Journal of Thermal Analysis and Calorimetry, 2022, 147 : 4959 - 4970
  • [34] Combustion of aluminum powder using CO2 laser in O2/CO2 atmosphere under different pressure conditions
    Qiu, Qili
    Zhou, Yunan
    Liu, Jianzhong
    Shi, Wei
    Yang, Weijuan
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2022, 147 (08) : 4959 - 4970
  • [35] DIODE-LASER ABSORPTION PROBE OF VIBRATION VIBRATION ENERGY-TRANSFER IN CO2
    KREUTZ, TG
    ONEILL, JA
    FLYNN, GW
    JOURNAL OF PHYSICAL CHEMISTRY, 1987, 91 (22): : 5540 - 5543
  • [36] NO-CO Monitoring Technique Using Ultraviolet Absorption Spectroscopy and Tunable Diode Laser Absorption Spectroscopy in High-Temperature and High-Pressure
    Zhou, Wangzheng
    Qin, Xiaowei
    Wang, Zhenzhen
    Deguchi, Yoshihiro
    Chong, Daotong
    Yan, Junjie
    APPLIED SPECTROSCOPY, 2025,
  • [37] Artificial absorption creation for more accurate tunable diode laser absorption spectroscopy measurement
    Wei, Wei
    Chang, Jun
    Cao, Lihua
    Liu, Yuanyuan
    Chen, Xi
    Zhu, Cunguang
    Qin, Zengguang
    OPTICS COMMUNICATIONS, 2017, 399 : 112 - 119
  • [38] A Portable Tunable Diode Laser Absorption Spectroscopy System for Dissolved CO2 Detection Using a High-Efficiency Headspace Equilibrator
    Zhang, Zhihao
    Li, Meng
    Guo, Jinjia
    Du, Baolu
    Zheng, Ronger
    SENSORS, 2021, 21 (05) : 1 - 15
  • [39] Spatial resolved temperature measurement based on absorption spectroscopy using a single tunable diode laser
    Yu, Xilong
    Li, Fei
    Chen, Lihong
    Zhang, Xinyu
    ACTA MECHANICA SINICA, 2010, 26 (01) : 147 - 149
  • [40] Gas Temperature Measurement Using First Harmonic Based on Tunable Diode Laser Absorption Spectroscopy
    Zhang, Keke
    Qi, Yong
    Chen, Shizhe
    Miao, Bin
    Yan, Xingkui
    Bai, Xuejiao
    2014 11TH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION (WCICA), 2014, : 2929 - 2933