Design and Analysis of a Power Quality Improvement System for Photovoltaic Generation Based on LCL-Type Grid Connected Inverter

被引:2
|
作者
Hosseinpour, M. [1 ]
Dastgiri, A. [1 ]
Shahparasti, M. [2 ]
机构
[1] Univ Mohaghegh Ardabili, Dept Elect & Comp Engn, Ardebil 5619911367, Iran
[2] Univ Vaasa, Sch Technol & Innovat, Vaasa, Finland
来源
INTERNATIONAL JOURNAL OF ENGINEERING | 2024年 / 37卷 / 02期
关键词
Photovoltaic Array; Grid-Connected Inverter; LCL Filter; Active Damping; CURRENT-FEEDBACK; VOLTAGE FEEDFORWARD; FILTER DESIGN; PV; STABILITY; COMPENSATION; CONVERTERS; STRATEGY; POINT;
D O I
10.5829/ije.2024.37.02b.04
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Grid-connected inverters are considered vital elements for effectively connecting renewable energy sources and distributed generation system applications. Ripple-induced current harmonics in DC link and high switching frequency are the disadvantages of grid-connected inverters that are reduced by LCL filters. However, the intrinsic resonance in the LCL filter leads to instability of the power transmission system. As a result, suitable damping is essential for removing resonance in the LCL filters. The contribution of this paper is to improve the quality of injectable power of LCL filter-based gridconnected photovoltaic array. For this contribution, the stability of the grid-connected inverter has been investigated using active damping method, and maximum power point tracking (MPPT) for the PV array has been performed. The capacitor voltage feedforward active damping method considering computational delay is presented in this paper. By using the inverter-side current feedback beside this method, the proposed control maintains the system's low-frequency specifications independent of the grid impedance changes. It provides high harmonic rejection capability without additional compensators. Also, the number of sensors is decreased due to the alternative measurement of the capacitor voltage instead of the grid voltage for the phase lock loop (PLL). Meanwhile, maximum power point tracking is implemented using the incremental conductance (IC) technique in the boost converter. In addition, a simple and suitable computational method for designing LCL filter parameters is presented, and the system's sensitivity is analyzed. Finally, the simulation has been implemented in MATLAB software that indicates the accurate performance of the control system in injecting the maximum power of the photovoltaic array into the grid and the highly desirable quality of the injectable current to the grid.
引用
收藏
页码:252 / 267
页数:16
相关论文
共 50 条
  • [31] A resonance suppression strategy of LCL-type grid-connected inverter based on compound voltage feedforward
    Yan, Haichao
    Zhao, Mi
    Lu, Min
    Cen, HongLei
    2023 24TH INTERNATIONAL CONFERENCE ON ELECTRONIC PACKAGING TECHNOLOGY, ICEPT, 2023,
  • [32] Design of A Photovoltaic Grid Connected Control System Based on LCL Filters
    Luo Xiaohui
    AGRO FOOD INDUSTRY HI-TECH, 2017, 28 (03): : 3031 - 3036
  • [33] Adaptive minimally switched grid connected photovoltaic inverter for power quality improvement
    Thekkath, Preethi
    Umapathy, Prabha Subramaniam
    JOURNAL OF ELECTRICAL SYSTEMS, 2014, 10 (03) : 250 - 262
  • [34] Analysis on Operation Characteristics of Grid - connected Inverter in Photovoltaic Power Generation
    Wang Zhijie
    Jin Yue
    Shi Zhong
    Yang Sen
    Yu, Yang Xiao
    2018 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2018, : 851 - 854
  • [35] Controller design for LCL-type grid-connected inverter to achieve high robustness against grid-impedance variation
    State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science & Technology, Wuhan
    Hubei Province
    430074, China
    Zhongguo Dianji Gongcheng Xuebao, 10 (2558-2566): : 2558 - 2566
  • [36] Power Quality Improvement Utilizing Photovoltaic Generation Connected to a Weak Grid
    Tumbelaka, Hanny H.
    Muljadi, Eduard
    Gao, Wenzhong
    2017 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2017, : 2983 - 2990
  • [37] A Weighted Average Feedforward Scheme for LCL-Type Grid-Connected Inverter with High LCL Resonance Frequency
    Wang, Cheng
    Wang, Xuehua
    Ruan, Xinbo
    Liu, Fuxin
    2020 IEEE 11TH INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS FOR DISTRIBUTED GENERATION SYSTEMS (PEDG), 2020, : 370 - 375
  • [38] Design of Photovoltaic Generation Grid-connected Inverter Based on DSP
    Yu Fei
    Guo Hong-mi
    Chu Yanhe
    MANUFACTURING SCIENCE AND TECHNOLOGY, PTS 1-8, 2012, 383-390 : 3443 - 3448
  • [39] A power quality control system based on grid-connected photovoltaic power generation
    Wang, Xiao
    Luo, An
    Deng, Caibo
    Shuai, Zhikang
    Sun, Yunbin
    Xiao, Ping
    Dianwang Jishu/Power System Technology, 2012, 36 (04): : 68 - 73
  • [40] Robust Grid-Current-Feedback Resonance Suppression Method for LCL-Type Grid-Connected Inverter Connected to Weak Grid
    Zhou, Xiaoping
    Zhou, Leming
    Chen, Yandong
    Shuai, Zhikang
    Guerrero, Josep M.
    Luo, An
    Wu, Wenhua
    Yang, Ling