Design and Analysis of a Power Quality Improvement System for Photovoltaic Generation Based on LCL-Type Grid Connected Inverter

被引:2
|
作者
Hosseinpour, M. [1 ]
Dastgiri, A. [1 ]
Shahparasti, M. [2 ]
机构
[1] Univ Mohaghegh Ardabili, Dept Elect & Comp Engn, Ardebil 5619911367, Iran
[2] Univ Vaasa, Sch Technol & Innovat, Vaasa, Finland
来源
INTERNATIONAL JOURNAL OF ENGINEERING | 2024年 / 37卷 / 02期
关键词
Photovoltaic Array; Grid-Connected Inverter; LCL Filter; Active Damping; CURRENT-FEEDBACK; VOLTAGE FEEDFORWARD; FILTER DESIGN; PV; STABILITY; COMPENSATION; CONVERTERS; STRATEGY; POINT;
D O I
10.5829/ije.2024.37.02b.04
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Grid-connected inverters are considered vital elements for effectively connecting renewable energy sources and distributed generation system applications. Ripple-induced current harmonics in DC link and high switching frequency are the disadvantages of grid-connected inverters that are reduced by LCL filters. However, the intrinsic resonance in the LCL filter leads to instability of the power transmission system. As a result, suitable damping is essential for removing resonance in the LCL filters. The contribution of this paper is to improve the quality of injectable power of LCL filter-based gridconnected photovoltaic array. For this contribution, the stability of the grid-connected inverter has been investigated using active damping method, and maximum power point tracking (MPPT) for the PV array has been performed. The capacitor voltage feedforward active damping method considering computational delay is presented in this paper. By using the inverter-side current feedback beside this method, the proposed control maintains the system's low-frequency specifications independent of the grid impedance changes. It provides high harmonic rejection capability without additional compensators. Also, the number of sensors is decreased due to the alternative measurement of the capacitor voltage instead of the grid voltage for the phase lock loop (PLL). Meanwhile, maximum power point tracking is implemented using the incremental conductance (IC) technique in the boost converter. In addition, a simple and suitable computational method for designing LCL filter parameters is presented, and the system's sensitivity is analyzed. Finally, the simulation has been implemented in MATLAB software that indicates the accurate performance of the control system in injecting the maximum power of the photovoltaic array into the grid and the highly desirable quality of the injectable current to the grid.
引用
收藏
页码:252 / 267
页数:16
相关论文
共 50 条
  • [21] Robust Delay Compensation Strategy for LCL-Type Grid-Connected Inverter in Weak Grid
    Ding, Xin
    Xue, Ruinan
    Zheng, Tianzhi
    Kong, Fannie
    Chen, Yanming
    IEEE ACCESS, 2022, 10 : 67639 - 67652
  • [22] Investigation of the Sideband Effect for the LCL-type Grid-connected Inverter with High LCL Resonance Frequency
    Yang, Dongsheng
    Wang, Xiongfei
    Blaabjerg, Frede
    2017 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2017, : 5601 - 5606
  • [23] The Grid-Connected Techniques for Input-Series-Output-Series LCL-Type Inverter System
    Han, Zhuwen
    Fang, Tianzhi
    Zhang, Xianyun
    Ruan, Xinbo
    2017 19TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'17 ECCE EUROPE), 2017,
  • [24] Design and control of LCL-type grid-tied PV power conditioning system based on inverter and grid side currents double feedback
    Hosseinpour, Majid
    Sabetfar, Tooraj
    Dejamkhooy, Abdolmajid
    Shahparasti, Mahdi
    INTERNATIONAL JOURNAL OF MODELLING AND SIMULATION, 2025, 45 (01): : 343 - 363
  • [25] A New Control Scheme for LCL-type Grid-connected Inverter With a Notch Filter
    Zhao, Qiangsong
    Liang, Fen
    Li, Weifeng
    2015 27TH CHINESE CONTROL AND DECISION CONFERENCE (CCDC), 2015, : 4073 - 4077
  • [26] Multisampling Control of LCL-type Grid-connected Inverter with an Improved Repetitive Filter
    He, Shan
    Zhou, Dao
    Wang, Xiongfei
    Blaabjerg, Frede
    2020 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2020, : 4336 - 4341
  • [27] A Frequency Adaptive Scheme Based on Newton Structure of PRRC for LCL-Type Inverter Connected with Weak Grid
    Zeng, Chengbi
    Li, Sudan
    Wang, Hanwen
    Miao, Hong
    ENERGIES, 2021, 14 (14)
  • [28] Stability analysis of digitally controlled LCL-type grid-connected inverter considering the delay effect
    Lyu, Yongcan
    Lin, Hua
    Cui, Yesheng
    IET POWER ELECTRONICS, 2015, 8 (09) : 1651 - 1660
  • [29] A Novel Two Degrees of Freedom Grid Current Regulation for Single-Phase LCL-type Photovoltaic Grid-Connected Inverter
    Zhou, Leming
    Luo, An
    Chen, Yandong
    Zhou, Xiaoping
    Chen, Zhiyong
    2016 IEEE 8TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE (IPEMC-ECCE ASIA), 2016,
  • [30] A weighted average mixed feedback control method based on LCL-type grid-connected inverter
    Li, Yulong
    Yang, Ming
    Yang, Zhuo
    Zhu, Jun
    INTERNATIONAL JOURNAL OF CIRCUIT THEORY AND APPLICATIONS, 2024, 52 (02) : 723 - 748