Accuracy of Traditional and Modern Formulas for Intraocular Lens Power Calculation After Radial Keratotomy Using Standard Keratometry

被引:2
|
作者
Helaly, Hany Ahmed [1 ,2 ]
Elhady, Amr Mohamed [1 ]
Elnaggar, Osama Ramadan [1 ]
机构
[1] Alexandria Univ, Fac Med, Ophthalmol Dept, Alexandria, Egypt
[2] Alexandria Univ, Fac Med, Ophthalmol Dept, 30 Roshdy St, Alexandria, Egypt
来源
CLINICAL OPHTHALMOLOGY | 2023年 / 17卷
关键词
radial keratotomy; IOL calculation; PEARL-DGS; Barrett True-K; DK Holladay 1; DK SRK/T; CORNEAL TOPOGRAPHY; CATARACT-SURGERY;
D O I
10.2147/OPTH.S417336
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the accuracy of multiple traditional and modern intraocular lens (IOL) power calculation formulas in post-radial keratotomy (RK) patients undergoing cataract surgery.Methods: This retrospective case series included 50 eyes with prior RK who underwent routine phacoemulsification surgery with single-piece acrylic IOL implantation (A constant = 118.8). Outcomes of multiple formulas were calculated. Included formulas were SRK/T, Holladay 1, Holladay 2, Haigis, Barrett True-K, Haigis and Barrett True-K (target refraction of 0.50 D), Barrett Universal II, Kane, PEARL-DGS, Shammas no history, DK SRK/T, DK SRK/T (target refraction of 0.50 D), Double K (DK) Holladay 1, and DK Holladay 1 (target refraction of 0.50 D). Averages of multiple combinations of best-performing single formulas were calculated. Primary outcome is mean absolute error (MAE).Results: Haigis (with -0.50 D target refraction) and DK SRK/T showed the lowest mean and median absolute errors (MedAE) followed by Haigis, Barrett True-K, and Barrett True-K (with -0.50 D target refraction). Combinations of 3, 4, or 5 of best performing single formulas yielded good results with >60% of cases within +0.50 D of intended refraction and MAE around 0.50 D. The best performing formulas with flatter K readings were PEARL-DGS and Haigis (with additional -0.50 D target refraction) with MAE of 0.72 + 0.71 D and 0.70 + 0.70 D, respectively, followed by Barrett True-K (with intended -0.50 D target refraction) with MAE of 0.75 + 0.63 D.Conclusion: Using an average of three or more Haigis (with -0.50 D target refraction), the Barrett True-K, DK Holladay 1, and DK SRK/T formulas showed better outcomes than using a single formula for IOLMaster 700 standard K readings. The PEARL-DGS formula showed better accuracy in eyes with flatter K readings (<38 D).
引用
收藏
页码:2589 / 2597
页数:9
相关论文
共 50 条
  • [31] Accuracy of Ten Intraocular Lens Formulas in Spherical Equivalent of Toric Intraocular Lens Power Calculation
    Shi, Jingyi
    Zhu, Zehui
    Hu, Bin
    Qian, Shuyi
    Wang, Yalan
    Chang, Pingjun
    Zhao, Yun-e
    OPHTHALMOLOGY AND THERAPY, 2024, 13 (05) : 1321 - 1342
  • [32] Accuracy of modern intraocular lens power calculation formulas in refractive lens exchange for high myopia and high hyperopia
    Terzi, Evdoxia
    Wang, Li
    Kohnen, Thomas
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (07): : 1181 - 1189
  • [33] Application of total keratometry in ten intraocular lens power calculation formulas in highly myopic eyes
    Ling Wei
    Kaiwen Cheng
    Wenwen He
    Xiangjia Zhu
    Yi Lu
    Eye and Vision, 9
  • [34] INTRAOCULAR-LENS POWER CALCULATION FOR EYES AFTER REFRACTIVE KERATOTOMY
    HOFFER, KJ
    JOURNAL OF REFRACTIVE SURGERY, 1995, 11 (06): : 490 - 493
  • [35] Application of total keratometry in ten intraocular lens power calculation formulas in highly myopic eyes
    Wei, Ling
    Cheng, Kaiwen
    He, Wenwen
    Zhu, Xiangjia
    Lu, Yi
    EYE AND VISION, 2022, 9 (01)
  • [36] Accuracy of Intraocular Lens Power Calculation Formulas for Highly Myopic Eyes
    Zhang, Yichi
    Liang, Xiao Ying
    Liu, Shu
    Lee, Jacky W. Y.
    Bhaskar, Srinivasan
    Lam, Dennis S. C.
    JOURNAL OF OPHTHALMOLOGY, 2016, 2016
  • [37] Prediction accuracy of standard and total keratometry by swept-source optical biometer for multifocal intraocular lens power calculation
    Hun Lee
    Jae Lim Chung
    Young Jun Kim
    Jae Yong Kim
    Hungwon Tchah
    Scientific Reports, 11
  • [38] Accuracy of intraocular lens power calculation formulas for highly myopic eyes
    Zhang, Yichi
    Liang, Xiao Ying
    Liu, Shu
    Lee, Jacky W. Y.
    Bhaskar, Srinivasan
    Lam, Dennis S. C.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [39] Intraocular lens constant optimization in toric intraocular lens calculation using keratometry and total corneal power
    Liang, Jianheng
    Liu, Hui
    Zhou, Suowang
    Zhou, Lijing
    Qian, Zhuyun
    Jiang, Lihong
    Chen, Xu
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2023, 33 (01) : 230 - 238
  • [40] Prediction accuracy of standard and total keratometry by swept-source optical biometer for multifocal intraocular lens power calculation
    Lee, Hun
    Chung, Jae Lim
    Kim, Young Jun
    Kim, Jae Yong
    Tchah, Hungwon
    SCIENTIFIC REPORTS, 2021, 11 (01)