Efficient estimation of tuned liquid column damper inerter (TLCDI) parameters for seismic control of base-isolated structures

被引:14
|
作者
Masnata, Chiara [1 ]
Di Matteo, Alberto [1 ]
Adam, Christoph [2 ]
Pirrotta, Antonina [1 ]
机构
[1] Univ Palermo, Dept Engn, Palermo, Italy
[2] Univ Innsbruck, Unit Appl Mech, Technikerstr 13, Innsbruck, Austria
关键词
VIBRATION CONTROL; MASS DAMPERS; EARTHQUAKE RESPONSE; OPTIMAL-DESIGN; HYBRID CONTROL; SYSTEMS;
D O I
10.1111/mice.12929
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
This paper presents an enhanced base-isolation (BI) system equipped with a novel passive control device composed of a tuned liquid damper and an inerter (TLCDI). With the aim of reducing the seismic response of BI systems, this contribution focuses on the design of the TLCDI providing analytical solutions for the optimal TLCDI parameters, easily implementable in the design phase. The effectiveness of the proposed approach in terms of seismic response reduction and computational gain is validated by comparison with classical numerical optimization techniques. The control performance of two different base-isolated TLCDI-controlled structures is assessed by employing real-ground motion records, and relevant comparisons with both uncontrolled base-isolated structures and equipped with a conventional TLCD are presented.
引用
收藏
页码:1638 / 1656
页数:19
相关论文
共 50 条
  • [1] Nontraditional configuration of tuned liquid column damper inerter for base-isolated structures
    Masnata, Chiara
    Di Matteo, Alberto
    Adam, Christoph
    Pirrotta, Antonina
    MECHANICS RESEARCH COMMUNICATIONS, 2023, 129
  • [2] Assessment of the tuned mass damper inerter for seismic response control of base-isolated structures
    Masnata, Chiara
    Di Matteo, Alberto
    Adam, Christoph
    Pirrotta, Antonina
    STRUCTURAL CONTROL & HEALTH MONITORING, 2021, 28 (02):
  • [3] Optimum Tuned Inerter Damper for Base-Isolated Structures
    R. S. Jangid
    Journal of Vibration Engineering & Technologies, 2021, 9 : 1483 - 1497
  • [4] Optimum Tuned Inerter Damper for Base-Isolated Structures
    Jangid, R. S.
    JOURNAL OF VIBRATION ENGINEERING & TECHNOLOGIES, 2021, 9 (07) : 1483 - 1497
  • [5] Tuned Liquid Column Damper Inerter (TLCDI) for Wind-Induced Vibration Control of Fixed-Base Structures
    Chiara, Masnata
    Di Matteo, Alberto
    Adam, Christoph
    Pirrotta, Antonina
    PERSPECTIVES IN DYNAMICAL SYSTEMS I-APPLICATIONS, DSTA 2021, 2024, 453 : 351 - 368
  • [6] Seismic response control of base-isolated structures with fluid inerter damper
    Akhare, Ashish R.
    INTERNATIONAL JOURNAL OF STRUCTURAL ENGINEERING, 2023, 13 (01) : 1 - 21
  • [7] Optimum parameters and performance of tuned mass damper-inerter for base-isolated structures
    Jangid, Radhey Shyam
    SMART STRUCTURES AND SYSTEMS, 2022, 29 (04) : 549 - 560
  • [8] Optimal design of tuned liquid column dampers for seismic response control of base-isolated structures
    Alberto Di Matteo
    Thomas Furtmüller
    Christoph Adam
    Antonina Pirrotta
    Acta Mechanica, 2018, 229 : 437 - 454
  • [9] Optimal design of tuned liquid column dampers for seismic response control of base-isolated structures
    Di Matteo, Alberto
    Furtmueller, Thomas
    Adam, Christoph
    Pirrotta, Antonina
    ACTA MECHANICA, 2018, 229 (02) : 437 - 454
  • [10] Seismic response control of adjacent high-rise buildings linked by the Tuned Liquid Column Damper-Inerter (TLCDI)
    Wang, Qinhua
    Qiao, Haoshuai
    De Domenico, Dario
    Zhu, Zhiwen
    Tang, Yi
    ENGINEERING STRUCTURES, 2020, 223 (223)