"sCT-Feasibility" - a feasibility study for deep learning-based MRI-only brain radiotherapy

被引:0
|
作者
Grigo, Johanna [1 ,2 ]
Szkitsak, Juliane [1 ,2 ]
Hoefler, Daniel [1 ,2 ]
Fietkau, Rainer [1 ,2 ]
Putz, Florian [1 ,2 ]
Bert, Christoph [1 ,2 ]
机构
[1] Friedrich Alexander Univ Erlangen Nurnberg FAU, Univ Klinikum Erlangen, Dept Radiat Oncol, Univ Str 27, DE-91054 Erlangen, Germany
[2] Comprehens Canc Ctr Erlangen EMN CCC ER EMN, Erlangen, Germany
关键词
MRI; Radiotherapy; MRI-only workflow; sCT; Synthetic CT; Deep learning; Stereotactic radiotherapy; MRonly; Artificial intelligence; STEREOTACTIC RADIOSURGERY; CT IMAGES; RADIATION; IMPLEMENTATION;
D O I
10.1186/s13014-024-02428-3
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
BackgroundRadiotherapy (RT) is an important treatment modality for patients with brain malignancies. Traditionally, computed tomography (CT) images are used for RT treatment planning whereas magnetic resonance imaging (MRI) images are used for tumor delineation. Therefore, MRI and CT need to be registered, which is an error prone process. The purpose of this clinical study is to investigate the clinical feasibility of a deep learning-based MRI-only workflow for brain radiotherapy, that eliminates the registration uncertainty through calculation of a synthetic CT (sCT) from MRI data.MethodsA total of 54 patients with an indication for radiation treatment of the brain and stereotactic mask immobilization will be recruited. All study patients will receive standard therapy and imaging including both CT and MRI. All patients will receive dedicated RT-MRI scans in treatment position. An sCT will be reconstructed from an acquired MRI DIXON-sequence using a commercially available deep learning solution on which subsequent radiotherapy planning will be performed. Through multiple quality assurance (QA) measures and reviews during the course of the study, the feasibility of an MRI-only workflow and comparative parameters between sCT and standard CT workflow will be investigated holistically. These QA measures include feasibility and quality of image guidance (IGRT) at the linear accelerator using sCT derived digitally reconstructed radiographs in addition to potential dosimetric deviations between the CT and sCT plan. The aim of this clinical study is to establish a brain MRI-only workflow as well as to identify risks and QA mechanisms to ensure a safe integration of deep learning-based sCT into radiotherapy planning and delivery.DiscussionCompared to CT, MRI offers a superior soft tissue contrast without additional radiation dose to the patients. However, up to now, even though the dosimetrical equivalence of CT and sCT has been shown in several retrospective studies, MRI-only workflows have still not been widely adopted. The present study aims to determine feasibility and safety of deep learning-based MRI-only radiotherapy in a holistic manner incorporating the whole radiotherapy workflow.Trial registrationNCT06106997.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Deep learning MRI-only synthetic-CT generation for pelvis, brain and head and neck cancers
    Bird, David
    Speight, Richard
    Andersson, Sebastian
    Wingqvist, Jenny
    Al-Qaisieh, Bashar
    RADIOTHERAPY AND ONCOLOGY, 2024, 191
  • [32] MRI-Based Synthetic CT for MRI-Only Proton Radiotherapy Treatment Planning
    Yang, X.
    Hedrick, S.
    Wang, T.
    Lei, Y.
    Jiang, X.
    Mao, H.
    Curran, W.
    McDonald, M.
    Liu, T.
    MEDICAL PHYSICS, 2018, 45 (06) : E360 - E360
  • [33] Deep learning-based fast volumetric imaging using kV and MV projection images for lung cancer radiotherapy: A feasibility study
    Lei, Yang
    Tian, Zhen
    Wang, Tonghe
    Roper, Justin
    Xie, Huiqiao
    Kesarwala, Aparna H. H.
    Higgins, Kristin
    Bradley, Jeffrey D. D.
    Liu, Tian
    Yang, Xiaofeng
    MEDICAL PHYSICS, 2023, 50 (09) : 5518 - 5527
  • [34] Synthetic CT calculation from low-field MRI: feasibility of an MRI-only workflow for glioblastoma RT
    Nesvacil, N.
    Herrmann, H.
    Persson, E.
    Siversson, C.
    Knausl, B.
    Kuess, P.
    Olsson, L. E.
    Georg, D.
    Nyholm, T.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S866 - S867
  • [35] Feasibility of Deep Learning-Based PET/MR Attenuation Correction in the Pelvis Using Only Diagnostic MR Images
    Bradshaw, Tyler J.
    Zhao, Gengyan
    Jang, Hyungseok
    Liu, Fang
    McMillan, Alan B.
    TOMOGRAPHY, 2018, 4 (03) : 138 - 147
  • [36] Development and evaluation of a deep learning based artificial intelligence for automatic identification of gold fiducial markers in an MRI-only prostate radiotherapy workflow
    Gustafsson, Christian Jamtheim
    Sward, Johan
    Adalbjornsson, Stefan Ingi
    Jakobsson, Andreas
    Olsson, Lars E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (22):
  • [37] Feasibility of MRI-Only Treatment Planning for Stereotactic Body Radiation Therapy (SBRT) for Prostate Cancer
    Nosrati, R.
    Lam, W.
    Paudel, M.
    Pejovic-Milic, A.
    Morton, G.
    Stanisz, G.
    MEDICAL PHYSICS, 2020, 47 (06) : E619 - E619
  • [38] Feasibility of MRI-only treatment planning for proton therapy in brain and prostate cancers: Dose calculation accuracy in substitute CT images
    Koivula, Lauri
    Wee, Leonard
    Korhonen, Juha
    MEDICAL PHYSICS, 2016, 43 (08) : 4634 - 4642
  • [39] MRI-Only Radiotherapy Planning with Varian's Hyperarc SRS System for Brain Metastases
    Houston, P. J.
    Ingram, W.
    Currie, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : E764 - E764
  • [40] Deep learning cycleGAN MRI-only synthetic-CT generation for pelvis, brain and head and neck cancers
    Bird, D.
    Speight, R.
    Andersson, S.
    Wingqvist, J.
    Al-Qaisieh, B.