An integrated and fast imaging quality assurance phantom for a 0.35 T magnetic resonance imaging linear accelerator

被引:1
|
作者
Sohn, James J. [1 ]
Lim, Sara [1 ]
Das, Indra J. [1 ]
Yadav, Poonam [1 ]
机构
[1] Northwestern Univ, Northwestern Mem Hosp, Dept Radiat Oncol, Feinberg Sch Med, Chicago, IL 60611 USA
关键词
Magnetic resonance imaging linear accelerator; Imaging; Magnetic resonance imaging guided radiation; therapy; MRIdian; QA; Magphan; ACR alternatives; MR-LINAC; RADIATION; IMPLEMENTATION;
D O I
10.1016/j.phro.2023.100462
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Periodic imaging quality assurance (QA) of magnetic resonance imaging linear accelerator (MRL) is critical. The feasibility of a new MRL imaging phantom used for QA in the low field was evaluated with auto-mated image analysis of various parameters for accuracy and reproducibility. Methods and materials: The new MRL imaging phantom was scanned across every 30 degrees of the gantry, having the on/off state of the linac in a low-field MRL system using three magnetic resonance imaging sequences: true fast imaging with steady-state precession (TrueFISP), T1 weighted (T1W), and T2 weighted (T2W). The DICOM files were used to calculate the imaging parameters: geometric distortion, uniformity, resolution, signal-to-noise ratio (SNR), and laser alignment. The point spread function (PSF) and edge spread function (ESF) were also calculated for resolution analysis. Results: The phantom data showed a small standard deviation -and high consistency for each imaging parameter. The highest variability in data was observed with the true fast imaging sequence at the calibration angle, which was expected because of low resolution and short scan time (25 sec). The mean magnitude of the largest distortion measured within 200 mm diameter with TrueFISP was 0.31 & PLUSMN; 0.05 mm. The PSF, ESF, signal uni-formity, and SNR measurements remained consistent. Laser alignment traditional offsets and angular deviation remained consistent. Conclusions: The new MRL imaging phantom is reliable, reproducible, time effective, and easy to use for a 0.35 T MRL system. The results promise a more streamlined, time-saving, and error-free QA process for low-field MRL adapted in our clinical setting.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Initial Evaluation of An MR-Compatible Phantom for Daily Imaging Quality Assurance (QA) Using a 0.35 T MR Linear Accelerator
    Romaguera, T.
    Perez, P.
    Obrien, V.
    Mittauer, K.
    McCulloch, J.
    Alvarez, D.
    Tolakanahalli, R.
    Chuong, M.
    Gutierrez, A.
    MEDICAL PHYSICS, 2022, 49 (06) : E233 - E233
  • [2] Accurate, repeatable, and geometrically precise diffusion-weighted imaging on a 0.35 T magnetic resonance imaging-guided linear accelerator
    Weygand, Joseph
    Armstrong, Tess
    Bryant, John Michael
    Andreozzi, Jacqueline M.
    Oraiqat, Ibrahim M.
    Nichols, Steven
    Liveringhouse, Casey L.
    Latifi, Kujtim
    Yamoah, Kosj
    Costello, James R.
    Frakes, Jessica M.
    Moros, Eduardo G.
    El Naqa, Issam M.
    Naghavi, Arash O.
    Rosenberg, Stephen A.
    Redler, Gage
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2023, 28
  • [3] Quality Assurance Testing Methods and Customized Phantom for Magnetic Resonance Imaging and Spectroscopy
    Song, K-H
    Lee, D-W
    Choe, B-Y
    MEDICAL PHYSICS, 2015, 42 (06) : 3255 - 3255
  • [4] QUALITY ASSURANCE IN MAGNETIC-RESONANCE IMAGING
    PRICE, RR
    PATTON, JA
    ERICKSON, JJ
    PICKENS, DR
    RUNGE, V
    PARTAIN, CL
    JAMES, AE
    MEDICAL PHYSICS, 1984, 11 (03) : 412 - 413
  • [5] Magnetic resonance imaging quality control, quality assurance and quality improvement
    Sreedher, Gayathri
    Ho, Mai-Lan
    Smith, Mark
    Udayasankar, Unni K.
    Risacher, Seretha
    Rapalino, Otto
    Greer, Mary-Louise C.
    Doria, Andrea S.
    Gee, Michael S.
    PEDIATRIC RADIOLOGY, 2021, 51 (05) : 698 - 708
  • [6] Magnetic resonance imaging quality control, quality assurance and quality improvement
    Gayathri Sreedher
    Mai-Lan Ho
    Mark Smith
    Unni K. Udayasankar
    Seretha Risacher
    Otto Rapalino
    Mary-Louise C. Greer
    Andrea S. Doria
    Michael S. Gee
    Pediatric Radiology, 2021, 51 : 698 - 708
  • [7] A novel multimodality anthropomorphic phantom enhances compliance with quality assurance guidelines for magnetic resonance imaging in radiotherapy
    Alzahrani, Meshal
    Broadbent, David A.
    Teh, Irvin
    Al-Qaisieh, Bashar
    Johnstone, Emily
    Speight, Richard
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2025, 33
  • [8] Quality assurance phantom for digital dental imaging
    Mah, Peter
    McDavid, W. Doss
    Dove, S. Brent
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2011, 112 (05): : 632 - 639
  • [9] Cardiac magnetic resonance imaging using an open 0.35 T system
    Klein, Hans-Martin
    Meyners, Werner
    Neeb, Benjamin
    Labenz, Joachim
    Truemmler, Karl-Heinz
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2007, 31 (03) : 430 - 434
  • [10] Magnetic resonance imaging - Current status of the discussion on quality assurance
    Fischer, J
    RADIOLOGE, 2001, 41 (05): : M73 - M74