Shutdown dose rate analysis with the Shift Monte Carlo radiation transport code and modular verification workflow

被引:1
|
作者
Bae, Jin Whan [1 ]
Kos, Bor [1 ]
Biondo, Elliott [1 ]
机构
[1] Oak Ridge Natl Lab, 1 Bethel Valley Rd, Oak Ridge, TN 37830 USA
关键词
R2S; SDDR; Shutdown dose rate analysis; MCNP; ITER; Shift; ORIGEN; VARIANCE REDUCTION; NEUTRON-TRANSPORT; CADIS METHOD; CAPABILITIES; VALIDATION; DEPLETION;
D O I
10.1016/j.fusengdes.2023.113895
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Calculation of the shutdown dose rate is crucial for safe fusion reactor operations. The Rigorous-two-step (R2S) method is a method that requires connected neutron transport, activation, and gamma transport. Shift has integrated variance reduction with a deterministic solver Denovo, supports multiple geometry formats, and is scalable. These features make it an attractive transport solver choice for an R2S workflow. An R2S workflow for the Shift Monte Carlo code is developed and compared to the existing Oak Ridge National Laboratory Shutdown Dose Rate Code Suite (ORCS) workflow. Also, a Python framework for integrating two R2S workflows is developed to mix and match each step in the R2S workflow for improved collaboration and verification experience. Results show that the Shift-Denovo R2S workflow and the ORCS workflow calculate the shutdown dose rate of the ITER Shutdown Dose Rate benchmark problem with an average relative error of 2.285%.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] A Monte Carlo transport code study of the space radiation environment using FLUKA and ROOT
    Wilson, T
    Pinsky, L
    Carminati, F
    Brun, R
    Ferrari, A
    Sala, P
    Empl, A
    MacGibbon, J
    SPACE TECHNOLOGY AND APPLICATIONS INTERNATIONAL FORUM-2001, 2001, 552 : 1234 - 1239
  • [42] Adaptation of a nuclear fusion radiation transport Monte Carlo code for HID lamp modelling
    Börner, P
    Reiter, D
    Born, M
    Giese, H
    Wiesen, S
    Baeva, M
    LIGHT SOURCES 2004, 2004, (182): : 407 - 408
  • [43] The effect on radiation damage of structural material in a hybrid system by using a Monte Carlo radiation transport code
    Gunay, Mehtap
    Sarer, Basar
    Kasap, Hizir
    ANNALS OF NUCLEAR ENERGY, 2014, 63 : 157 - 161
  • [44] Monte Carlo Study of Radiation Dose Enhancement by Gadolinium in Megavoltage and High Dose Rate Radiotherapy
    Zhang, Daniel G.
    Feygelman, Vladimir
    Moros, Eduardo G.
    Latifi, Kujtim
    Zhang, Geoffrey G.
    PLOS ONE, 2014, 9 (10):
  • [45] Development of shutdown dose rate calculation code based on cosRMC and application to benchmark analysis
    Zhang, Xian
    Liu, Shichang
    Lu, Peng
    Zhang, Xiaokang
    Zheng, Yu
    Chen, Yixue
    Liu, Songlin
    FUSION ENGINEERING AND DESIGN, 2021, 173
  • [46] Clinical verification of treatment planning dose calculation in lung SBRT with GATE Monte Carlo simulation code
    Boiset, Gisell Ruiz
    Batista, Delano V. S.
    Cardoso, Simone Coutinho
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 87 : 1 - 10
  • [47] Verification of 3D-CRT dose distribution in ArcCheck phantom using Monte Carlo code
    Yani, Sitti
    Noviantoro, Yosia Adityo
    Husin, Abd Djamil
    Rhani, Mohamad Fahdillah
    Sumaryada, Tony
    Haryanto, Freddy
    RADIATION PHYSICS AND CHEMISTRY, 2023, 210
  • [48] Development and verification of transport and tally capabilities based on unstructured mesh in Reactor Monte Carlo code RMC
    Li, Jie
    Shen, Pengfei
    Liu, Zhaoyuan
    Li, Qing
    Wang, Kan
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2025, 57 (06)
  • [49] MCSIM: A Monte Carlo dose verification tool for radiation therapy treatment planning and beam delivery
    Ma, C
    Li, J
    Pawlicki, T
    Jiang, S
    Deng, J
    Chen, L
    Wang, L
    Price, R
    McNeeley, S
    Ding, M
    Fourkal, E
    Qin, L
    MEDICAL PHYSICS, 2002, 29 (06) : 1316 - 1316
  • [50] Analysis of Kobayashi benchmark with indigenous Monte Carlo neutron transport code PATMOC
    Mallick, Amod Kishore
    Kannan, Umasankari
    PHYSICS OPEN, 2023, 17