Clinical validation of a wearable respiratory rate device: A brief report

被引:2
|
作者
Eisenkraft, Arik [1 ,2 ,3 ]
Goldstein, Nir [1 ]
Ben Ishay, Arik [1 ]
Fons, Meir [1 ]
Tabi, Michael [1 ]
Sherman, Anna Danielle [1 ]
Merin, Roei [1 ,4 ]
Nachman, Dean [2 ,3 ,5 ]
机构
[1] Biobeat Technol Ltd, Petah Tiqwa, Israel
[2] Hebrew Univ Jerusalem, Inst Res Mil Med, Fac Med, POB 12272, IL-91120 Jerusalem, Israel
[3] Israel Def Force Med Corps, POB 12272, IL-91120 Jerusalem, Israel
[4] Tel Aviv Sourasky Med Ctr, Tel Aviv, Israel
[5] Hebrew Univ Jerusalem, Heart Inst, Hadassah Med Ctr, Jerusalem, Israel
关键词
Remote patient monitoring; respiratory rate; breaths per minute; comparative study; continuous monitoring;
D O I
10.1177/14799731231198865
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background: Respiratory rate (RR) is used for the diagnosis and management of medical conditions and can predict clinical changes. Heavy workload, understaffing, and errors related to poor recording make it underutilized. Wearable devices may facilitate its use. Methods: RR measurements using a wearable photoplethysmography-based monitor were compared with medical grade devices in complementary clinical scenarios: Study one included a comparison to a capnograph in 35 healthy volunteers; Study two included a comparison to a ventilator monitor in 18 ventilated patients; and Study three included a comparison to capnograph in 92 COVID-19 patients with active pulmonary disease. Pearson's correlations and Bland-Altman analysis were used to assess the accuracy and agreement between the measurement techniques, including stratification for Body Mass Index (BMI) and skin tone. Statistical significance was set at p <= 0.05. Results: High correlation was found in all studies (r = 0.991, 0.884, and 0.888, respectively, p < 0.001 for all). 95% LOA of +/- 2.3, 1.7-(-1.6), and +/- 3.9 with a bias of < 0.1 breaths per minute was found in Bland-Altman analysis in studies 1,2, and 3, respectively. In all, high accordance was found in all sub-groups. Conclusions: RR measurements using the wearable monitor were highly-correlated with medical-grade devices in various clinical settings. Trial registration: ClinicalTrials.gov, https://clinicaltrials.gov/ct2/show/NCT03603860.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Contactless and continuous monitoring of respiratory rate in a hospital ward: a clinical validation study
    Toften, Stale
    Kjellstadli, Jonas T.
    Kvaerness, Jorn
    Pedersen, Line
    Laugsand, Lars E.
    Thu, Ole K. F.
    FRONTIERS IN PHYSIOLOGY, 2024, 15
  • [32] Electrocardiogram Derived Respiratory Rate Using a Wearable Armband
    Lazaro, Jesus
    Reljin, Natasa
    Bailon, Raquel
    Gil, Eduardo
    Noh, Yeonsik
    Laguna, Pablo
    Chon, Ki H.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2021, 68 (03) : 1056 - 1065
  • [33] Respiratory Rate Detection Using a Wearable Electromagnetic Generator
    Padasdao, Bryson
    Boric-Lubecke, Olga
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 3217 - 3220
  • [34] ECG Derived Respiratory Rate Estimation for Wearable Devices
    Rajagopalan, Pradeep
    Ramachandran, Sabarish
    2017 INTERNATIONAL CONFERENCE ON COMPUTATIONAL INTELLIGENCE IN DATA SCIENCE (ICCIDS), 2017,
  • [35] A Wearable Capacitive Sensor for Monitoring Human Respiratory Rate
    Kundu, Subrata Kumar
    Kumagai, Shinya
    Sasaki, Minoru
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2013, 52 (04)
  • [36] Assessing Electrocardiogram and Respiratory Signal Quality of a Wearable Device (SensEcho): Semisupervised Machine Learning-Based Validation Study
    Xu, Haoran
    Yan, Wei
    Lan, Ke
    Ma, Chenbin
    Wu, Di
    Wu, Anshuo
    Yang, Zhicheng
    Wang, Jiachen
    Zang, Yaning
    Yan, Muyang
    Zhang, Zhengbo
    JMIR MHEALTH AND UHEALTH, 2021, 9 (08):
  • [37] Monitoring respiratory impedance by wearable sensor device: Protocol and methodology
    Ionescu, Clara M.
    Copot, D.
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2017, 36 : 57 - 62
  • [38] Validation of a novel wearable monitoring patch for continuous respiratory monitoring
    John, M.
    Van der Westen, R. Garcia
    Yordanova, G.
    Groenendaal, W.
    Agell, C.
    John, M.
    EUROPEAN RESPIRATORY JOURNAL, 2022, 60
  • [39] Validation of Impact Forces Estimated by Wearable Device VERT in Volleyball
    De Bleecker, Camilla
    Vermeulen, Stefan
    Willems, Tine
    Segers, Veerle
    Spanhove, Valentien
    Leys, Rowan
    Vanrenterghem, Jos
    De Ridder, Roel
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2025, 39 (03) : e458 - e462
  • [40] Validation of an Ear-Worn Wearable Gait Analysis Device