Clinical validation of a wearable respiratory rate device: A brief report

被引:2
|
作者
Eisenkraft, Arik [1 ,2 ,3 ]
Goldstein, Nir [1 ]
Ben Ishay, Arik [1 ]
Fons, Meir [1 ]
Tabi, Michael [1 ]
Sherman, Anna Danielle [1 ]
Merin, Roei [1 ,4 ]
Nachman, Dean [2 ,3 ,5 ]
机构
[1] Biobeat Technol Ltd, Petah Tiqwa, Israel
[2] Hebrew Univ Jerusalem, Inst Res Mil Med, Fac Med, POB 12272, IL-91120 Jerusalem, Israel
[3] Israel Def Force Med Corps, POB 12272, IL-91120 Jerusalem, Israel
[4] Tel Aviv Sourasky Med Ctr, Tel Aviv, Israel
[5] Hebrew Univ Jerusalem, Heart Inst, Hadassah Med Ctr, Jerusalem, Israel
关键词
Remote patient monitoring; respiratory rate; breaths per minute; comparative study; continuous monitoring;
D O I
10.1177/14799731231198865
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background: Respiratory rate (RR) is used for the diagnosis and management of medical conditions and can predict clinical changes. Heavy workload, understaffing, and errors related to poor recording make it underutilized. Wearable devices may facilitate its use. Methods: RR measurements using a wearable photoplethysmography-based monitor were compared with medical grade devices in complementary clinical scenarios: Study one included a comparison to a capnograph in 35 healthy volunteers; Study two included a comparison to a ventilator monitor in 18 ventilated patients; and Study three included a comparison to capnograph in 92 COVID-19 patients with active pulmonary disease. Pearson's correlations and Bland-Altman analysis were used to assess the accuracy and agreement between the measurement techniques, including stratification for Body Mass Index (BMI) and skin tone. Statistical significance was set at p <= 0.05. Results: High correlation was found in all studies (r = 0.991, 0.884, and 0.888, respectively, p < 0.001 for all). 95% LOA of +/- 2.3, 1.7-(-1.6), and +/- 3.9 with a bias of < 0.1 breaths per minute was found in Bland-Altman analysis in studies 1,2, and 3, respectively. In all, high accordance was found in all sub-groups. Conclusions: RR measurements using the wearable monitor were highly-correlated with medical-grade devices in various clinical settings. Trial registration: ClinicalTrials.gov, https://clinicaltrials.gov/ct2/show/NCT03603860.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] A consumer wearable device for tracking sleep respiratory events
    Pasquale Tondo
    Francesco Dell’Olio
    Donato Lacedonia
    Roberto Sabato
    Rosa Leccisotti
    Maria Pia Foschino Barbaro
    Giulia Scioscia
    Sleep and Breathing, 2023, 27 : 1485 - 1489
  • [22] A consumer wearable device for tracking sleep respiratory events
    Tondo, Pasquale
    Dell'Olio, Francesco
    Lacedonia, Donato
    Sabato, Roberto
    Leccisotti, Rosa
    Barbaro, Maria Pia Foschino
    Scioscia, Giulia
    SLEEP AND BREATHING, 2023, 27 (04) : 1485 - 1489
  • [24] Development of wearable device designs for respiratory infection prevention
    Hu, Bowei
    Koo, Sumin
    INTERNATIONAL JOURNAL OF CLOTHING SCIENCE AND TECHNOLOGY, 2022, 34 (05) : 764 - 781
  • [25] Wearable Device Heart Rate and Activity Data in an Unsupervised Approach to Personalized Sleep Monitoring: Algorithm Validation
    Liu, Jiaxing
    Zhao, Yang
    Lai, Boya
    Wang, Hailiang
    Tsui, Kwok Leung
    JMIR MHEALTH AND UHEALTH, 2020, 8 (08):
  • [26] Development and validation of a 'MyLyt' wearable light tracking device
    Dhakal, Rohit
    Rudrapankte, Jagadesh Rao
    Chittajallu, Harsha S. N. S.
    Lawrenson, John G.
    Huntjens, Byki
    Shah, Rakhee
    Verkicharla, Pavan K.
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2023, 43 (01) : 132 - 140
  • [27] Development and Validation of a Wearable Plantar Force Measurement Device
    McMillan, Lachlan B.
    Von Treuheim, Theodor Di Pauli
    Murphy, Anna
    Zengin, Ayse
    Ebeling, Peter R.
    Scott, David
    IEEE SENSORS JOURNAL, 2019, 19 (11) : 4008 - 4016
  • [28] Validation of Spectral Indices of Electrodermal Activity with a Wearable Device
    McNaboe, Riley Q.
    Hossain, Md-Billal
    Kong, Youngsun
    Chon, Ki H.
    Posada-Quintero, Hugo F.
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 6991 - 6994
  • [29] Measurement of respiratory rate by a fibber optic device: a clinical study in healthy volunteers
    Calmels, V.
    De Jonckheere, J.
    Jeanne, M.
    Aboulrhit, I.
    Chaud, P.
    Deplanque, D.
    Logier, R.
    FUNDAMENTAL & CLINICAL PHARMACOLOGY, 2011, 25 : 47 - 47
  • [30] Reliability and validity of a wearable heart rate and respiratory rate sensor system
    Tharion, William J.
    Buller, Mark J.
    Karis, Anthony J.
    Mullen, Stephen P.
    FASEB JOURNAL, 2008, 22