Accuracy of digital impressions for three- unit and four-unit implant supported fixed dental prostheses using a novel device

被引:8
|
作者
Kao, Tzu-Yung [1 ]
Hsieh, Min-Chieh [1 ]
Liao, Chi -Chun [2 ,3 ]
Chang, Chih-Ling [1 ,4 ,5 ]
机构
[1] Shin Kong Wu Ho Su Mem Hosp, Dept Prosthodont, Taipei, Taiwan
[2] Natl Taiwan Univ Sci & Technol, High Speed Printing Res Ctr 3D, Taipei, Taiwan
[3] Jien Shin Dent Lab, Taipei, Taiwan
[4] Natl Yang Ming Chiao Tung Univ, Sch Dent, Taipei, Taiwan
[5] Shin Kong Wu Ho Su Mem Hosp, Dept Prosthodont, B1F,95 Wen Chang Rd, Taipei 11101, Taiwan
关键词
Accuracy; Digital impression; Intraoral scan body; Intraoral scanner; PRECISION;
D O I
10.1016/j.jds.2022.10.014
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background/ purpose: Accuracy of digital implant impressions was considered questionable due to the lack of anatomical reference points between implants and the similar-ities in scan body morphology, which lead to the purpose of this research is to propose a simple and convenient technique to improve the accuracy of scanning.Materials and methods: Four implant analogues (teeth: 15, 17, 24, and 27) were inserted into a stone model of a partially edentulous maxilla; two implants were inserted on each side, creating a three-unit span and a four-unit span. The model was scanned using a 3Shape E4 dental laboratory scanner for reference and a TRIOS 3 intraoral scanner for testing. Each side was scanned 10 times, both with and without the novel device attached to the scan bodies. The trueness and precision of interimplant distances (linear deviations), and interimplant an-gulations (angle deviations) between the scan bodies were determined using software. A Mann-Whitney U test was used to determine statistical differences between subgroups.Results: Significant differences were discovered in the trueness of angular deviations (-0.20 degrees +/- 0.15 degrees vs.-0.01 degrees +/- 0.11o) and precision of linear deviations (11.14 +/- 6.35 vs. 3.10 +/- 2.14 mm) for the four-unit groups.Conclusion: The novel device significantly improved scanning accuracy for a four-unit groups (approximately 22.93 mm) compared to three-unit groups. 2022 Association for Dental Sciences of the Republic of China. Publishing services by Elsevier B.V. This is an open access article under the CC BY license (http://creativecommons.org/ licenses/by/4.0/).
引用
收藏
页码:702 / 708
页数:7
相关论文
共 50 条
  • [31] Clinical outcomes of single implant supported crowns versus 3-unit implant-supported fixed dental prostheses in Dubai Health Authority: a retrospective study
    Alhammadi, Sara Hussain
    Burnside, Girvan
    Milosevic, Alexander
    BMC ORAL HEALTH, 2021, 21 (01)
  • [32] Clinical outcomes of single implant supported crowns versus 3-unit implant-supported fixed dental prostheses in Dubai Health Authority: a retrospective study
    Sara Hussain Alhammadi
    Girvan Burnside
    Alexander Milosevic
    BMC Oral Health, 21
  • [33] Accuracy of conventional impressions and digital scans for implant-supported fixed prostheses in maxillary free-ended partial edentulism: An in vitro study
    El Osta, Nada
    Drancourt, Noemie
    Auduc, Chantal
    Veyrune, Jean-Luc
    Nicolas, Emmanuel
    JOURNAL OF DENTISTRY, 2024, 143
  • [34] Digital measurement method for comparing the absolute marginal discrepancy of three-unit ceramic fixed dental prostheses fabricated using conventional and digital technologies
    Liang, Shanshan
    Yuan, Fusong
    Li, Deli
    Jia, Lu
    Sun, Yuchun
    BMC ORAL HEALTH, 2023, 23 (01)
  • [35] Digital measurement method for comparing the absolute marginal discrepancy of three-unit ceramic fixed dental prostheses fabricated using conventional and digital technologies
    Shanshan Liang
    Fusong Yuan
    Deli Li
    Lu Jia
    Yuchun Sun
    BMC Oral Health, 23
  • [36] Comparison of Accuracy of Fit of Three-Unit Fixed Ceramic Cobalt-Chromium Dental Prostheses Fabricated by Three Different Techniques
    Daou, Elie E.
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2021, 34 (05) : 642 - 649
  • [37] Guided implant scanning: A procedure for improving the accuracy of implant-supported complete-arch fixed dental prostheses
    Gomez-Polo, Miguel
    Ballesteros, Juan
    Perales-Padilla, Pedro
    Perales-Pulido, Pedro
    Gomez-Polo, Cristina
    Ortega, Rocio
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (02): : 135 - 139
  • [38] Strain Behavior of Implant-Supported Full-Arch Fixed Dental Prostheses Supported by Four or Five Implants
    Sbardelotto, Cristian
    Lapria Faria, Adriana Claudia
    Tiossi, Rodrigo
    Ribeiro, Ricardo Faria
    Silveira Rodrigues, Renata Cristina
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (01) : 153 - 158
  • [39] Accuracy of digital impressions for implant-supported complete-arch prosthesis when using an auxiliary geometry device
    Arikan, Hale
    Muhtarogullari, Mehmet
    Uzel, Sema Merve
    Guncu, Mustafa Baris
    Aktas, Guliz
    Marshall, Lindsay Simone
    Turkyilmaz, Ilser
    JOURNAL OF DENTAL SCIENCES, 2023, 18 (02) : 808 - 813
  • [40] Comparison of Implant Survival Rates and Biologic and Mechanical Complications with Implant-Supported Fixed Complete Dental Prostheses Using Four and Six Implants
    Tamer, Yusuf
    Ozcan, Isil
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2023, 43 (04) : E157 - E163