Accuracy of digital impressions for three- unit and four-unit implant supported fixed dental prostheses using a novel device

被引:8
|
作者
Kao, Tzu-Yung [1 ]
Hsieh, Min-Chieh [1 ]
Liao, Chi -Chun [2 ,3 ]
Chang, Chih-Ling [1 ,4 ,5 ]
机构
[1] Shin Kong Wu Ho Su Mem Hosp, Dept Prosthodont, Taipei, Taiwan
[2] Natl Taiwan Univ Sci & Technol, High Speed Printing Res Ctr 3D, Taipei, Taiwan
[3] Jien Shin Dent Lab, Taipei, Taiwan
[4] Natl Yang Ming Chiao Tung Univ, Sch Dent, Taipei, Taiwan
[5] Shin Kong Wu Ho Su Mem Hosp, Dept Prosthodont, B1F,95 Wen Chang Rd, Taipei 11101, Taiwan
关键词
Accuracy; Digital impression; Intraoral scan body; Intraoral scanner; PRECISION;
D O I
10.1016/j.jds.2022.10.014
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background/ purpose: Accuracy of digital implant impressions was considered questionable due to the lack of anatomical reference points between implants and the similar-ities in scan body morphology, which lead to the purpose of this research is to propose a simple and convenient technique to improve the accuracy of scanning.Materials and methods: Four implant analogues (teeth: 15, 17, 24, and 27) were inserted into a stone model of a partially edentulous maxilla; two implants were inserted on each side, creating a three-unit span and a four-unit span. The model was scanned using a 3Shape E4 dental laboratory scanner for reference and a TRIOS 3 intraoral scanner for testing. Each side was scanned 10 times, both with and without the novel device attached to the scan bodies. The trueness and precision of interimplant distances (linear deviations), and interimplant an-gulations (angle deviations) between the scan bodies were determined using software. A Mann-Whitney U test was used to determine statistical differences between subgroups.Results: Significant differences were discovered in the trueness of angular deviations (-0.20 degrees +/- 0.15 degrees vs.-0.01 degrees +/- 0.11o) and precision of linear deviations (11.14 +/- 6.35 vs. 3.10 +/- 2.14 mm) for the four-unit groups.Conclusion: The novel device significantly improved scanning accuracy for a four-unit groups (approximately 22.93 mm) compared to three-unit groups. 2022 Association for Dental Sciences of the Republic of China. Publishing services by Elsevier B.V. This is an open access article under the CC BY license (http://creativecommons.org/ licenses/by/4.0/).
引用
收藏
页码:702 / 708
页数:7
相关论文
共 50 条
  • [11] Marginal accuracy of four-unit zirconia fixed dental prostheses fabricated using different computer-aided design/computer-aided manufacturing systems
    Kohorst, Philipp
    Brinkmann, Henrike
    Li, Jiang
    Borchers, Lothar
    Stiesch, Meike
    EUROPEAN JOURNAL OF ORAL SCIENCES, 2009, 117 (03) : 319 - 325
  • [12] Three-unit fixed prostheses versus implant-supported single crowns
    Christensen, Gordon J.
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2008, 139 (02): : 191 - 194
  • [13] Four-unit fixed dental prostheses replacing the maxillary incisors supported by two narrow-diameter implants - a five-year case series
    Moraguez, Osvaldo
    Vailati, Francesca
    Grutter, Linda
    Sailer, Irena
    Belser, Urs C.
    CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (07) : 887 - 892
  • [14] Digitally Produced Fiber-Reinforced Composite Substructures for Three-Unit Implant-Supported Fixed Dental Prostheses
    Bonfante, Estevam A.
    Suzuki, Marcelo
    Carvalho, Ricardo M.
    Hirata, Ronaldo
    Lubelski, Will
    Bonfante, Gerson
    Pegoraro, Thiago A.
    Coelho, Paulo G.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2015, 30 (02) : 321 - 329
  • [15] Prospective Clinical Study of Zirconia-Based Posterior Four-Unit Fixed Dental Prostheses: Four-Year Follow-up
    Salido, Maria P.
    Martinez-Rus, Francisco
    del Rio, Fernando
    Pradies, Guillermo
    Oezcan, Mutlu
    Suarez, Maria J.
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2012, 25 (04) : 403 - 409
  • [16] Fracture resistance of monolithic and veneered all-ceramic four-unit posterior fixed dental prostheses after artificial aging
    Gungor, Merve B.
    Nemli, Secil K.
    Bal, Bilge T.
    Tamam, Even
    Yilmaz, Handan
    Aydin, Cemal
    JOURNAL OF ORAL SCIENCE, 2019, 61 (02) : 246 - 254
  • [17] Influence of intraoral conditions on the accuracy of digital and conventional implant impression techniques for two-implant-supported fixed dental prostheses
    Ma, Yun
    Guo, Yong-qing
    Jiang, Lei
    Yu, Hao
    JOURNAL OF PROSTHODONTIC RESEARCH, 2023, 67 (04) : 633 - 640
  • [18] Precision of fit: zirconia three-unit fixed dental prostheses
    Beuer, Florian
    Naumann, Michael
    Gernet, Wolfgang
    Sorensen, John A.
    CLINICAL ORAL INVESTIGATIONS, 2009, 13 (03) : 343 - 349
  • [19] Precision of fit: zirconia three-unit fixed dental prostheses
    Florian Beuer
    Michael Naumann
    Wolfgang Gernet
    John A. Sorensen
    Clinical Oral Investigations, 2009, 13
  • [20] Finite Element Analysis of a New Non-Engaging Abutment System for Three-Unit Implant-Supported Fixed Dental Prostheses
    Byun, Soo-Hwan
    Seo, Joung-Hwa
    Cho, Ran-Yeong
    Yi, Sang-Min
    Kim, Lee-Kyong
    Han, Hyun-Sook
    On, Sung-Woon
    Kim, Won-Hyeon
    An, Hyun-Wook
    Yang, Byoung-Eun
    BIOENGINEERING-BASEL, 2022, 9 (10):