A 4.5 μW Miniaturized 3-Channel Wireless Intra-Cardiac Acquisition System

被引:1
|
作者
Rezaeiyan, Yasser [1 ]
Koolivand, Yarallah [2 ]
Zamani, Milad [1 ]
Shoaei, Omid [3 ]
Akbari, Meysam [4 ]
Moradi, Farshad [1 ]
Tang, Kea-Tiong [5 ]
机构
[1] Aarhus Univ, Dept Engn, Integrated Circuits & Elect Lab, DK-8200 Aarhus, Denmark
[2] KN Toosi Univ Technol, Elect Engn, Tehran 1541849611, Iran
[3] Univ Tehran, Sch Elect & Comp Engn, Biointegrated Syst Lab, Tehran 1439957131, Iran
[4] Univ Kurdistan, Dept Elect Engn, Sanandaj 6617715175, Iran
[5] Natl Tsing Hua Univ, Dept Elect Engn, Hsinchu 30013, Taiwan
关键词
Monitoring; Modulation; Electrocardiography; Frequency modulation; Wireless communication; Transmitters; Receivers; Analog front-end (AFE); electrocardiography (ECG); intra-cardiac signal; implantable systems; wireless telemetry; FRONT-END; CHOPPER AMPLIFIER; DYNAMIC-RANGE; MODE; SOC; EXTRACTION; TOLERANT; SENSOR; ADC;
D O I
10.1109/TBCAS.2023.3294560
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This article presents a chip designed for wireless intra-cardiac monitoring systems. The design consists of a three-channel analog front-end, a pulse-width modulator featuring output-frequency offset and temperature calibration, and inductive data telemetry. By employing a resistance boosting technique in the instrumentation amplifier feedback, the pseudo-resistor exhibits lower non-linearity, leading to a total harmonic distortion of below 0.1%. Furthermore, the boosting technique enhances the feedback resistance, leading to a reduction in the size of the feedback capacitor and, consequently, the overall size. To make the modulator's output frequency resilient to temperature and process changes, coarse and fine-tuning algorithms are used. The front-end channel is capable of extracting the intra-cardiac signal with an effective number of bits of 8.9, while exhibiting an input-referred noise of less than 2.7 mu V-rms , and consuming 200 nW per channel. The front-end output is encoded by an ASK-PWM modulator, which drives an on-chip transmitter at 13.56 MHz. The proposed System-on-Chip (SoC) is fabricated in a 0.18 mu m standard CMOS technology and consumes 4.5 mu W while occupying 1.125 mm(2) .
引用
收藏
页码:1097 / 1110
页数:14
相关论文
共 50 条
  • [1] A 3-channel ECG measuring system for wireless applications
    Dorn, R.
    Voelker, M.
    Neubauer, H.
    Hauer, J.
    Johansson, J.
    2006 IEEE INTERNATIONAL WORKSHOP ON MEDICAL MEASUREMENT AND APPLICATIONS, 2006, : 49 - +
  • [2] 3-CHANNEL SYSTEM
    不详
    AUDIO, 1971, 55 (03): : 20 - &
  • [3] APPLICATION OF AN IMPROVED INTRA-CARDIAC FIBEROPTIC SYSTEM
    KROVETZ, LJ
    BRENNER, JI
    POLANYI, M
    OSTROWSKI, D
    BRITISH HEART JOURNAL, 1978, 40 (09): : 1010 - 1013
  • [4] The revolution of beat-to-beat wireless bidirectional communication between intra-cardiac devices
    Narducci, Maria Lucia
    Volpe, Massimo
    EUROPEAN HEART JOURNAL, 2023, 44 (34) : 3215 - 3216
  • [5] A 3-CHANNEL MICROCOMPUTER SYSTEM FOR SEGMENTATION AND CHARACTERIZATION OF THE PHONOCARDIOGRAM
    LEHNER, RJ
    RANGAYYAN, RM
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1987, 34 (06) : 485 - 489
  • [6] Clinical intra-cardiac 4D flow CMR: acquisition, analysis, and clinical applications
    Demirkiran, Ahmet
    van Ooij, Pim
    Westenberg, Jos J. M.
    Hofman, Mark B. M.
    van Assen, Hans C.
    Schoonmade, Linda J.
    Asim, Usman
    Blanken, Carmen P. S.
    Nederveen, Aart J.
    van Rossum, Albert C.
    Gotte, Marco J. W.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2022, 23 (02) : 154 - 165
  • [7] 3-CHANNEL PHASE STEPPED SYSTEM FOR MOIRE INTERFEROMETRY
    KUJAWINSKA, M
    SALBUT, L
    PATORSKI, K
    APPLIED OPTICS, 1991, 30 (13): : 1633 - 1635
  • [9] A Miniaturized 64-Channel 225μW Wireless Electrocorticographic Neural Sensor
    Muller, Rikky
    Le, Hanh-Phuc
    Li, Wen
    Ledochowitsch, Peter
    Gambini, Simone
    Bjorninen, Toni
    Koralek, Aaron
    Carmena, Jose M.
    Maharbiz, Michel M.
    Alon, Elad
    Rabaey, Jan M.
    2014 IEEE INTERNATIONAL SOLID-STATE CIRCUITS CONFERENCE DIGEST OF TECHNICAL PAPERS (ISSCC), 2014, 57 : 412 - +
  • [10] INITIAL DESIGN AND EVALUATION OF AN INTRA-CARDIAC CAMERA SYSTEM FOR VENTRICULAR SEPTAL DEFECTS
    Hart, Keir D.
    Mitchell, Max B.
    Rentschler, Mark E.
    PROCEEDINGS OF THE ASME INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE 2010, VOL 2, PTS A AND B, 2010, : 125 - 134